Literature DB >> 11847618

Collarless polished tapered stem: clinical and radiological follow-up over 5 years.

Piers Yates1, Dietmar Gobel, Gordon Bannister.   

Abstract

The clinical and radiologic outcome of a cemented, polished, tapered stem (CPT), implanted using contemporary cementing techniques in 108 consecutive operated hips in 100 patients (68 women and 32 men, aged 19 to 83 years at the time of surgery [mean, 65 years]) was assessed after >5 years. The Harris hip scores were good or excellent in 96% of the patients. Stem subsidence measured by the computer-assisted method described by Braud and Freeman was at a mean rate of 0.44 mm/y, 1.08 mm during the first year, and stabilizing to a mean total of 2.18 mm at >5 years. Subsidence was related inversely to the completeness of the cement mantle but did not correlate with the clinical or radiologic outcome. This study confirms that collarless, polished, tapered stems subside within the cement mantle but without loosening and that the CPT performs at least as well as the Exeter stem.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11847618     DOI: 10.1054/arth.2002.30292

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems.

Authors:  Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Kiyokazu Fukui; Kengo Yamada; Tadami Matsumoto
Journal:  Int Orthop       Date:  2006-04-14       Impact factor: 3.075

2.  Favourable mid-term results of the VerSys CT polished cemented femoral stem for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Adriana Zoppi; Eduardo A Salvati
Journal:  Int Orthop       Date:  2006-03-31       Impact factor: 3.075

3.  Initial evaluation on subsidence of cemented collarless polished tapered stem applied to the patients with narrow femoral medullar canal.

Authors:  Katsuyuki Dairaku; Masaji Ishii; Shinji Kobayashi; Hiroyuki Kawaji; Kan Sasaki; Yuya Takakubo; Michiaki Takagi
Journal:  Open Orthop J       Date:  2010-03-16

4.  Stem subsidence of polished and rough double-taper stems: in vitro mechanical effects on the cement-bone interface.

Authors:  Ayumi Kaneuji; Kengo Yamada; Kenichi Hirosaki; Masahiro Takano; Tadami Matsumoto
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

Review 5.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04

6.  A 2-year prospective clinical and bone density evaluation, with a subset undergoing radiostereometric analysis, using the Absolut cemented stem.

Authors:  Jay R Ebert; Nils O Nivbrant; Victoria Petrov; Piers Yates; David J Wood
Journal:  ANZ J Surg       Date:  2022-02-02       Impact factor: 2.025

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.