BACKGROUND AND PURPOSE: To analyze the interfractional set-up errors and intrafractional organ motions and to define appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins in intensity-modulated radiotherapy (IMRT) for head and neck tumors. PATIENTS AND METHODS: Twenty-two patients with head and neck or brain tumors who were treated with IMRT were enrolled. The set-up errors were defined as the displacements of the coordinates of bony landmarks on the beam films from those on the simulation films. The organ motions were determined as the displacements of the coordinates of the landmarks on the images recorded every 3 min for 15 min on the X-ray simulator from those on the initial image. RESULTS: The standard deviations (SDs) of the systematic set-up errors (Sigma-INTER) and organ motions (Sigma-intra) distributed with a range of 0.7-1.3 and 0.2-0.8 mm, respectively. The average of the SDs of the random set-up errors (sigma-INTER) and organ motions (sigma-intra) ranged from 0.7 to 1.6 mm and from 0.3 to 0.6 mm, respectively. Appropriate PTV-margins and PRV-margins for all the landmarks ranged from 2.0 to 3.6 mm and from 1.8 to 2.4 mm, respectively. CONCLUSIONS: We have adopted a PTV-margin of 5mm and a PRV-margin of 3mm for head and neck IMRT at our department.
RCT Entities:
BACKGROUND AND PURPOSE: To analyze the interfractional set-up errors and intrafractional organ motions and to define appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins in intensity-modulated radiotherapy (IMRT) for head and neck tumors. PATIENTS AND METHODS: Twenty-two patients with head and neck or brain tumors who were treated with IMRT were enrolled. The set-up errors were defined as the displacements of the coordinates of bony landmarks on the beam films from those on the simulation films. The organ motions were determined as the displacements of the coordinates of the landmarks on the images recorded every 3 min for 15 min on the X-ray simulator from those on the initial image. RESULTS: The standard deviations (SDs) of the systematic set-up errors (Sigma-INTER) and organ motions (Sigma-intra) distributed with a range of 0.7-1.3 and 0.2-0.8 mm, respectively. The average of the SDs of the random set-up errors (sigma-INTER) and organ motions (sigma-intra) ranged from 0.7 to 1.6 mm and from 0.3 to 0.6 mm, respectively. Appropriate PTV-margins and PRV-margins for all the landmarks ranged from 2.0 to 3.6 mm and from 1.8 to 2.4 mm, respectively. CONCLUSIONS: We have adopted a PTV-margin of 5mm and a PRV-margin of 3mm for head and neck IMRT at our department.
Authors: Adam D Yock; Adam S Garden; Laurence E Court; Beth M Beadle; Lifei Zhang; Lei Dong Journal: Int J Radiat Oncol Biol Phys Date: 2013-07-29 Impact factor: 7.038
Authors: Christina Leitzen; Timo Wilhelm-Buchstab; Thomas Müdder; Martina Heimann; David Koch; Christopher Schmeel; Birgit Simon; Sabina Stumpf; Susanne Vornholt; Stephan Garbe; Fred Röhner; Felix Schoroth; Hans Heinz Schild; Heinrich Schüller Journal: Strahlenther Onkol Date: 2018-01-25 Impact factor: 3.621
Authors: J Cacicedo; J F Perez; R Ortiz de Zarate; O del Hoyo; F Casquero; A Gómez-Iturriaga; A Lasso; E Boveda; P Bilbao Journal: Clin Transl Oncol Date: 2014-07-19 Impact factor: 3.405
Authors: Wei Liu; Samir H Patel; Jiajian Jason Shen; Yanle Hu; Daniel P Harrington; Xiaoning Ding; Michele Y Halyard; Steven E Schild; William W Wong; Gary A Ezzell; Martin Bues Journal: Pract Radiat Oncol Date: 2016-02-13