Literature DB >> 16564594

Analysis of interfractional set-up errors and intrafractional organ motions during IMRT for head and neck tumors to define an appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins.

Minoru Suzuki1, Yasumasa Nishimura, Kiyoshi Nakamatsu, Masahiko Okumura, Hisayuki Hashiba, Ryuta Koike, Shuichi Kanamori, Toru Shibata.   

Abstract

BACKGROUND AND
PURPOSE: To analyze the interfractional set-up errors and intrafractional organ motions and to define appropriate planning target volume (PTV)- and planning organs at risk volume (PRV)-margins in intensity-modulated radiotherapy (IMRT) for head and neck tumors. PATIENTS AND METHODS: Twenty-two patients with head and neck or brain tumors who were treated with IMRT were enrolled. The set-up errors were defined as the displacements of the coordinates of bony landmarks on the beam films from those on the simulation films. The organ motions were determined as the displacements of the coordinates of the landmarks on the images recorded every 3 min for 15 min on the X-ray simulator from those on the initial image.
RESULTS: The standard deviations (SDs) of the systematic set-up errors (Sigma-INTER) and organ motions (Sigma-intra) distributed with a range of 0.7-1.3 and 0.2-0.8 mm, respectively. The average of the SDs of the random set-up errors (sigma-INTER) and organ motions (sigma-intra) ranged from 0.7 to 1.6 mm and from 0.3 to 0.6 mm, respectively. Appropriate PTV-margins and PRV-margins for all the landmarks ranged from 2.0 to 3.6 mm and from 1.8 to 2.4 mm, respectively.
CONCLUSIONS: We have adopted a PTV-margin of 5mm and a PRV-margin of 3mm for head and neck IMRT at our department.

Entities:  

Mesh:

Year:  2006        PMID: 16564594     DOI: 10.1016/j.radonc.2006.03.006

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  31 in total

1.  Set-up errors and planning target volume margins in head and neck cancer radiotherapy: a clinical study of image guidance with on-line cone-beam computed tomography.

Authors:  Francesco Dionisi; Mauro Filippo Palazzi; Francesco Bracco; Maria Grazia Brambilla; Claudia Carbonini; Diego Dario Asnaghi; Angelo Filippo Monti; Alberto Torresin
Journal:  Int J Clin Oncol       Date:  2012-03-03       Impact factor: 3.402

2.  Clinical outcomes of IMRT planned with or without PET/CT simulation for patients with pharyngeal cancers.

Authors:  Tomohiro Matsuura; Yasumasa Nishimura; Kiyoshi Nakamatsu; Shuichi Kanamori; Kazuki Ishikawa; Izumi Tachibana; Makoto Hosono; Toru Shibata
Journal:  Int J Clin Oncol       Date:  2016-09-07       Impact factor: 3.402

3.  Anisotropic margin expansions in 6 anatomic directions for oropharyngeal image guided radiation therapy.

Authors:  Adam D Yock; Adam S Garden; Laurence E Court; Beth M Beadle; Lifei Zhang; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-07-29       Impact factor: 7.038

4.  Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).

Authors:  A Boughalia; S Marcie; M Fellah; S Chami; F Mekki
Journal:  Br J Radiol       Date:  2015-04-17       Impact factor: 3.039

5.  Dosimetric impact of intrafractional patient motion in pediatric brain tumor patients.

Authors:  Chris Beltran; John Trussell; Thomas E Merchant
Journal:  Med Dosim       Date:  2009-02-07       Impact factor: 1.482

6.  Patient positioning in head and neck cancer : Setup variations and safety margins in helical tomotherapy.

Authors:  Christina Leitzen; Timo Wilhelm-Buchstab; Thomas Müdder; Martina Heimann; David Koch; Christopher Schmeel; Birgit Simon; Sabina Stumpf; Susanne Vornholt; Stephan Garbe; Fred Röhner; Felix Schoroth; Hans Heinz Schild; Heinrich Schüller
Journal:  Strahlenther Onkol       Date:  2018-01-25       Impact factor: 3.621

7.  Impact of residual setup error on parotid gland dose in intensity-modulated radiation therapy with or without planning organ-at-risk margin.

Authors:  Anna Delana; Loris Menegotti; Andrea Bolner; Luigi Tomio; Aldo Valentini; Frank Lohr; Valentina Vanoni
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

8.  A prospective analysis of inter- and intrafractional errors to calculate CTV to PTV margins in head and neck patients.

Authors:  J Cacicedo; J F Perez; R Ortiz de Zarate; O del Hoyo; F Casquero; A Gómez-Iturriaga; A Lasso; E Boveda; P Bilbao
Journal:  Clin Transl Oncol       Date:  2014-07-19       Impact factor: 3.405

Review 9.  Head and neck cancer.

Authors:  Athanassios Argiris; Michalis V Karamouzis; David Raben; Robert L Ferris
Journal:  Lancet       Date:  2008-05-17       Impact factor: 79.321

10.  Robustness quantification methods comparison in volumetric modulated arc therapy to treat head and neck cancer.

Authors:  Wei Liu; Samir H Patel; Jiajian Jason Shen; Yanle Hu; Daniel P Harrington; Xiaoning Ding; Michele Y Halyard; Steven E Schild; William W Wong; Gary A Ezzell; Martin Bues
Journal:  Pract Radiat Oncol       Date:  2016-02-13