Literature DB >> 16530634

3T MR imaging of the musculoskeletal system (Part II): clinical applications.

R Richard Ramnath1.   

Abstract

The gain in SNR that is afforded by 3T MR imaging systems has tremendous clinical applications in the musculoskeletal system. The potential for demonstrating and enhancing the visibility of normal osseous, tendinous, cartilaginous, and ligamentous structures is exciting. Furthermore, harnessing this added signal to increase spatial resolution may improve our diagnostic abilities in various joints dramatically. Radiologists have enjoyed great success in assessing joint disease with current MR imaging field strengths; however, many intrinsic joint structures remain poorly evaluated, which leads to a golden opportunity for 3T MR imaging. The articular cartilage of the knee, the glenoid labrum of the shoulder, the intrinsic ligaments and TFC of the wrist, the collateral ligaments of the elbow, the labrum and articular cartilage of the hip, and the collateral ligaments of the ankle have been evaluated suboptimally on 1 .5T systems using routine nonarthrographic MR images. Because of the enhanced SNR, the higher spatial resolution, and the greater CNR of intrinsic joint structures at higher field strengths, 3T MR imaging has the potential to improve diagnostic abilities in the musculoskeletal system vastly, which translates into better patient care and management. The author's 2 years of clinical experience with musculoskeletal MR imaging on 3T systems has met and exceeded his expectations, and has bolstered the confidence of his orthopedic surgeons in his diagnoses. As coil technology advances and as the use of parallel imaging becomes more available in the extremities, the author expects to see even more dramatic improvements in image quality.

Entities:  

Mesh:

Year:  2006        PMID: 16530634     DOI: 10.1016/j.mric.2006.01.003

Source DB:  PubMed          Journal:  Magn Reson Imaging Clin N Am        ISSN: 1064-9689            Impact factor:   2.266


  23 in total

1.  Analysis of tunnel widening after double-bundle ACL reconstruction.

Authors:  Yong Seuk Lee; Sheen-Woo Lee; Shin Woo Nam; Won Seok Oh; Jae Ang Sim; Ji Hoon Kwak; Beom Koo Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-15       Impact factor: 4.342

2.  Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Y Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Skeletal Radiol       Date:  2012-02-10       Impact factor: 2.199

3.  Radiological diagnostic progress in skeletal diseases.

Authors:  Giuseppe Guglielmi; Michelangelo Nasuto; Michele La Porta
Journal:  Clin Cases Miner Bone Metab       Date:  2011-01

4.  3 T magnetic resonance imaging of the musculoskeletal system.

Authors:  G Guglielmi; N Biccari; F Mangano; R Toffanin
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

5.  Optimizing isotropic three-dimensional fast spin-echo methods for imaging the knee.

Authors:  Charles Q Li; Weitian Chen; Jarrett K Rosenberg; Philip J Beatty; Richard Kijowski; Brian A Hargreaves; Reed F Busse; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2014-06       Impact factor: 4.813

6.  A 3D Parallel Imaging Capable Transmit and 15-Channel Receive Array Knee Coil at 3T.

Authors:  Matthew Finnerty; Joseph Herczak; Tsinghua Zheng; Jacob Weaver; Xiaoyu Yang; Hiroyuki Fujita
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2008

7.  Comparative study of fat-suppression techniques for hip arthroplasty MR imaging.

Authors:  Sébastien Molière; Jean-Philippe Dillenseger; Matthieu Ehlinger; Stéphane Kremer; Guillaume Bierry
Journal:  Skeletal Radiol       Date:  2017-05-24       Impact factor: 2.199

8.  Effect of traction on wrist joint space and cartilage visibility with and without MR arthrography.

Authors:  Ryan K L Lee; James F Griffith; W K Tang; Alex W H Ng; David K W Yeung
Journal:  Br J Radiol       Date:  2017-02-09       Impact factor: 3.039

9.  Ligaments of the Lisfranc joint in MRI: 3D-SPACE (sampling perfection with application optimized contrasts using different flip-angle evolution) sequence compared to three orthogonal proton-density fat-saturated (PD fs) sequences.

Authors:  Erika J Ulbrich; Veronika Zubler; Reto Sutter; Norman Espinosa; Christian W Pfirrmann; Marco Zanetti
Journal:  Skeletal Radiol       Date:  2012-08-23       Impact factor: 2.199

10.  Initial results of in vivo high-resolution morphological and biochemical cartilage imaging of patients after matrix-associated autologous chondrocyte transplantation (MACT) of the ankle.

Authors:  Sebastian Quirbach; Siegfried Trattnig; Stefan Marlovits; Valentin Zimmermann; Stephan Domayer; Ronald Dorotka; Tallal C Mamisch; Klaus Bohndorf; Goetz H Welsch
Journal:  Skeletal Radiol       Date:  2009-03-19       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.