Literature DB >> 16530263

Intra-oral restorative materials wear: rethinking the current approaches: how to measure wear.

Ralph DeLong1.   

Abstract

OBJECTIVE: To determine what wear parameter(s) have clinical relevance and what factors are important for accurate measurement of these parameters in vivo and in vitro.
METHOD: Describe biomechanical factors affecting mastication and the mechanics of wear. Investigate how they impact the wear of teeth and restorative materials. Based on this information, define the advantages and disadvantages of using volume, depth, and area parameters to quantify wear. Describe direct and indirect methods of measuring wear and point out advantages and disadvantages of each.
RESULTS: The preferred parameter for quantifying wear is volume. It is independent of occlusal factors and is a measure of work done. If material and environmental factors remain constant, volume loss is linear with time. Depth and area have limited clinical value because of their dependence on occlusal factors; plus, they are not linear with time. When measuring wear the material of interest and the opposing material must be considered; especially if the opposing material is enamel. Wear is best measured by comparing sequential 3D images. Measuring systems should be calibrated with their error reported using sigma values rather means and standard deviations. The quality of the alignment of the sequential images should be included in the error analysis. Cost and availability of 3D imaging systems has severely limited their use in clinical studies. SIGNIFICANCE: Wear is an important consequence of occlusal interactions. If not controlled, wear could lead to poor masticatory function with a concomitant reduction in quality of life and possible deterioration of systemic health.

Mesh:

Substances:

Year:  2006        PMID: 16530263     DOI: 10.1016/j.dental.2006.02.003

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  28 in total

1.  Using occlusal wear information and finite element analysis to investigate stress distributions in human molars.

Authors:  Stefano Benazzi; Ottmar Kullmer; Ian R Grosse; Gerhard W Weber
Journal:  J Anat       Date:  2011-05-25       Impact factor: 2.610

2.  Dental materials for primary dentition: are they suitable for occlusal restorations? A two-body wear study.

Authors:  D Lazaridou; R Belli; N Krämer; A Petschelt; U Lohbauer
Journal:  Eur Arch Paediatr Dent       Date:  2014-10-25

3.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

4.  Nanohybrid and microfilled hybrid versus conventional hybrid composite restorations: 5-year clinical wear performance.

Authors:  Senthamaraiselvi Palaniappan; Liesbeth Elsen; Inge Lijnen; Marleen Peumans; Bart Van Meerbeek; Paul Lambrechts
Journal:  Clin Oral Investig       Date:  2011-01-11       Impact factor: 3.573

5.  The progressive wear and abrasiveness of novel graded glass/zirconia materials relative to their dental ceramic counterparts.

Authors:  Marina R Kaizer; Rafael R Moraes; Sergio S Cava; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

6.  Factors affecting wear of composite resin denture teeth--24-month results from a clinical study.

Authors:  Thomas Stober; Andreas Geiger; Stefan Rues; Jens Dreyhaupt; Peter Rammelsberg; Brigitte Ohlmann
Journal:  Clin Oral Investig       Date:  2011-03-08       Impact factor: 3.573

7.  Evaluation of the effectiveness of the new tooth wear measurement parameters.

Authors:  Sang-Hak Lee; Shin-Eun Nam; Seung-Pyo Lee
Journal:  Anat Cell Biol       Date:  2015-12-21

8.  In vitro abrasion of resin-coated highly viscous glass ionomer cements: a confocal laser scanning microscopy study.

Authors:  Özgur Kanik; L Sebnem Turkun; Walter Dasch
Journal:  Clin Oral Investig       Date:  2016-04-13       Impact factor: 3.573

9.  3D Simulation Modeling of the Tooth Wear Process.

Authors:  Ning Dai; Jian Hu; Hao Liu
Journal:  PLoS One       Date:  2015-08-04       Impact factor: 3.240

Review 10.  Tooth wear against ceramic crowns in posterior region: a systematic literature review.

Authors:  Rim Hmaidouch; Paul Weigl
Journal:  Int J Oral Sci       Date:  2013-10-18       Impact factor: 6.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.