Literature DB >> 16516728

Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius.

Tamara D Rozental1, Philip E Blazar.   

Abstract

PURPOSE: Despite the recent popularity of volar plating for dorsally displaced distal radius fractures there is a paucity of data documenting the results of this treatment method. The purpose of this study was to determine the functional outcome of patients treated with volar fixed-angle plating for dorsally displaced, unstable distal radius fractures.
METHODS: We reviewed the records of all patients treated at our institution with internal fixation using volar plates for dorsally displaced, comminuted distal radius fractures. Patients with follow-up periods shorter than 12 months were excluded from the study. Outcomes were evaluated at the latest follow-up examination with the Disabilities of the Arm, Shoulder, and Hand and the Gartland and Werley scoring systems.
RESULTS: We studied 41 patients with a mean age of 53 years. The average follow-up period was 17 months. All fractures were stabilized with volar locking plates. Radiographs in the immediate postoperative period showed a mean radial height of 11 mm, mean radial inclination of 21 degrees , and mean volar tilt of 4 degrees. At fracture healing the mean radial height was 11 mm, mean radial inclination was 21 degrees, and mean volar tilt was 5 degrees. The average score on the Disabilities of the Arm, Shoulder, and Hand questionnaire was 14 and all patients achieved excellent and good results on the Gartland and Werley scoring system, indicating minimal impairment in activities of daily living. Nine patients experienced postoperative complications. There were 4 instances of loss of reduction with fracture collapse, 3 patients required hardware removal for tendon irritation, 1 patient developed a wound dehiscence, and 1 patient had metacarpophalangeal joint stiffness.
CONCLUSIONS: Patients with unstable, dorsally displaced fractures of the distal radius treated with volar fixed-angle devices have good or excellent functional outcomes despite a high complication rate. When compared with previous reports on dorsal plating volar plates appear to have a higher incidence of fracture collapse but a lower rate of hardware-related complications. Complex fracture patterns thus mandate a careful and individualized approach. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level III.

Entities:  

Mesh:

Year:  2006        PMID: 16516728     DOI: 10.1016/j.jhsa.2005.10.010

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  88 in total

1.  The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.

Authors:  Lucile Vaiss; Satoshi Ichihara; Sarah Hendriks; Chihab Taleb; Philippe Liverneaux; Sybille Facca
Journal:  J Wrist Surg       Date:  2014-11

2.  [Stability of volar fixed-angle plating for distal radius fractures. Failure modes in osteoporotic bone].

Authors:  S Mair; P Weninger; F Högel; S Panzer; P Augat
Journal:  Unfallchirurg       Date:  2013-04       Impact factor: 1.000

3.  The cadaveric anatomy of the distal radius: implications for the use of volar plates.

Authors:  P A McCann; D Clarke; R Amirfeyz; R Bhatia
Journal:  Ann R Coll Surg Engl       Date:  2012-03       Impact factor: 1.891

4.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

5.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

6.  Outcomes following operative treatment of open fractures of the distal radius: a case control study.

Authors:  Brendan J MacKay; Nicole Montero; Nader Paksima; Kenneth A Egol
Journal:  Iowa Orthop J       Date:  2013

7.  A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures.

Authors:  Agnes Z Dardas; Charles A Goldfarb; Martin I Boyer; Daniel A Osei; Christopher J Dy; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2018-02-01       Impact factor: 2.230

8.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08

Review 9.  Considerations in the Treatment of Osteoporotic Distal Radius Fractures in Elderly Patients.

Authors:  Peter J Ostergaard; Matthew J Hall; Tamara D Rozental
Journal:  Curr Rev Musculoskelet Med       Date:  2019-03

10.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.