PURPOSE: Although volar plating of the distal radius is performed frequently, the necessity of distal bicortical fixation in the metaphyseal and epiphyseal areas of the distal radius has not been proven. This study aimed primarily to quantify the ability of unicortical distal screws to maintain operative reduction of adult distal radius fractures and secondarily to determine if unicortical screw lengths could be predicted based on anatomical measurements.
METHODS: This prospective trial enrolled 75 adult patients undergoing volar locking plate fixation of a unilateral distal radius fracture at a tertiary center. Study inclusion required screw fixation in the distal rows of the plate performed with unicortical screw placement. The primary outcome was maintenance of operative reduction, according to predefined parameters, quantified by comparing initial operative reduction to final reduction after fracture healing. Repeated measures analysis of variance analyzed for systematic change in radiographic parameters between injury, operative, and healed images. Correlation coefficients quantified the relationship of screw lengths with lunate width and other anatomical measurements.
RESULTS: Seventy-five patients (mean age, 54 years ± 15 years; 79% women) were enrolled and followed to fracture union. Fracture severity varied and included AO type A (40%), B (12%), and C (48%) fractures. There was no significant change in mean lateral translation, intra-articular gap, intra-articular stepoff, radial inclination, or lateral tilt of the radius between the time of fixation and union for the cohort. Two patients lost reduction (increased dorsal tilt, 10°, 20°, respectively), potentially attributable to provision of unicortical fixation (3%; 95% confidence interval [95% CI], 0%-9%). No extensor tenosynovitis or extensor tendon ruptures occurred. Eighty percent of screws were 18 mm or less and screw lengths were not correlated with lunate width or any other anatomical measurements.
CONCLUSIONS: Unicortical distal fixation during volar locking plate fixation effectively maintains operative reductions of distal radius fractures while potentially minimizing the incidence of extensor tendon ruptures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Volar plate; distal radius; fixation; fracture; unicortical

Mesh:

Year:  2018        PMID: 29395586      PMCID: PMC5936475          DOI: 10.1016/j.jhsa.2017.12.018

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  24 in total

1.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

2.  Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius Fractures: How Can You Best Detect?

Authors:  Brian W Hill; Irshad Shakir; Lisa K Cannada
Journal:  J Orthop Trauma       Date:  2015-10       Impact factor: 2.512

3.  Complications after volar locking plate fixation of distal radius fractures.

Authors:  N A Johnson; L Cutler; J J Dias; A S Ullah; C J Wildin; B Bhowal
Journal:  Injury       Date:  2013-10-14       Impact factor: 2.586

4.  Two potential causes of EPL rupture after distal radius volar plate fixation.

Authors:  Eric C Benson; Alex DeCarvalho; Elizabeth A Mikola; John M Veitch; Moheb S Moneim
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

5.  Fracture of the distal radius: risk factors for complications after locked volar plate fixation.

Authors:  Maximillian Soong; Roderick van Leerdam; Thierry G Guitton; Christopher Got; Julia Katarincic; David Ring
Journal:  J Hand Surg Am       Date:  2011-01       Impact factor: 2.230

6.  Assessment of complications of distal radius fractures and development of a complication checklist.

Authors:  S D McKay; J C MacDermid; J H Roth; R S Richards
Journal:  J Hand Surg Am       Date:  2001-09       Impact factor: 2.230

7.  The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography.

Authors:  Devin Ganesh; Ben Service; Brian Zirgibel; Kenneth Koval
Journal:  J Orthop Trauma       Date:  2016-11       Impact factor: 2.512

8.  Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures.

Authors:  M Al-Rashid; K Theivendran; M A C Craigen
Journal:  J Bone Joint Surg Br       Date:  2006-12

9.  Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases.

Authors:  J M Failla; M P Koniuch; B R Moed
Journal:  J Hand Surg Am       Date:  1993-07       Impact factor: 2.230

10.  Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events.

Authors:  Luigi Tarallo; Raffaele Mugnai; Francesco Zambianchi; Roberto Adani; Fabio Catani
Journal:  J Orthop Trauma       Date:  2013-12       Impact factor: 2.512

View more
  2 in total

1.  Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study.

Authors:  M Artuso; M Protais; O Herisson; A Miquel; A Cambon-Binder; A Sautet
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-04

2.  Radiocarpal joint stiffness following surgical treatment for distal radius fractures: the incidence and associated factors.

Authors:  Lingde Kong; Yajie Zhai; Zuzhuo Zhang; Jian Lu; Bing Zhang; Dehu Tian
Journal:  J Orthop Surg Res       Date:  2020-08-11       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.