Literature DB >> 16510962

MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems.

Aldo Badano1, Josep Sempau.   

Abstract

We describe MANTIS (Monte carlo x-rAy electroN opTical Imaging Simulation), a tool for simulating imaging systems that tracks x-rays, electrons and optical photons in arbitrary materials and complex geometries. The x-ray and electron transport and involved physics models are from the PENELOPE package, and the optical transport and corresponding physics models are from DETECT-II and include Fresnel refraction and reflection at material boundaries, bulk absorption and scattering. Complex geometries can be handled with the aid of the geometry routines included in PENELOPE. When x-rays or electrons interact and deposit energy in the scintillator, the code generates a number of optical quanta according to a user-selected model for the conversion process. The optical photons are then tracked until they reach an absorption event, which in some cases contributes to the output signal, or escape from the geometry. We demonstrate the capabilities of this new tool with respect to the statistics of the optical signal detected and to the three-dimensional point-response functions corresponding to columnar phosphor screens.

Entities:  

Mesh:

Year:  2006        PMID: 16510962     DOI: 10.1088/0031-9155/51/6/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems.

Authors:  Melanie Freed; Subok Park; Aldo Badano
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

Review 3.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

4.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

5.  Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens.

Authors:  Melanie Freed; Stuart Miller; Katherine Tang; Aldo Badano
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.

Authors:  Qian Cao; Alejandro Sisniega; Michael Brehler; J Webster Stayman; John Yorkston; Jeffrey H Siewerdsen; Wojciech Zbijewski
Journal:  Med Phys       Date:  2017-11-27       Impact factor: 4.071

7.  Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality.

Authors:  Ehsan Samei; Robert S Saunders
Journal:  Phys Med Biol       Date:  2011-09-09       Impact factor: 3.609

8.  Quantitative imaging to assess tumor response to therapy: common themes of measurement, truth data, and error sources.

Authors:  Charles R Meyer; Samuel G Armato; Charles P Fenimore; Geoffrey McLennan; Luc M Bidaut; Daniel P Barboriak; Marios A Gavrielides; Edward F Jackson; Michael F McNitt-Gray; Paul E Kinahan; Nicholas Petrick; Binsheng Zhao
Journal:  Transl Oncol       Date:  2009-12       Impact factor: 4.243

Review 9.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

10.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.