Literature DB >> 16498123

Radiation dose to the fetus from body MDCT during early gestation.

Lynne M Hurwitz1, Terry Yoshizumi, Robert E Reiman, Philip C Goodman, Erik K Paulson, Donald P Frush, Greta Toncheva, Giao Nguyen, Lottie Barnes.   

Abstract

OBJECTIVE: The purpose of our study was to determine radiation dose to the fetus at early gestation when contemporary MDCT scanners are used for common clinical indications.
MATERIALS AND METHODS: Anthropomorphic phantoms were constructed to reflect a pregnant woman. Thermoluminescence dosimeters (TLDs) and metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in appropriate locations to determine real-time radiation exposure to the fetus at 0 and 3 months' gestation. Imaging was performed on a 16-MDCT scanner using current institutional CT protocols: renal stone (140 kVp, 160 mA, rotation time of 0.5 sec, 16 x 0.625 mm), appendix (140 kVp, 340 mA, rotation time of 0.5 sec, 16 x 0.625 mm), and pulmonary embolus (140 kVp, 380 mA, rotation time of 0.8 sec, 16 x 1.25 mm).
RESULTS: The radiation dose to the fetus at 0 and 3 months, respectively, was as follows: renal stone protocol, 0.8-1.2 and 0.4-0.7 cGy; appendix protocol, 1.52-1.68 and 2-4 cGy; and pulmonary embolus protocol, 0.024-0.047 and 0.061-0.066 cGy.
CONCLUSION: Radiation doses to the fetus from institutional MDCT protocols that may be used during pregnancy (for pulmonary embolus, appendicitis, and renal colic) are below the level thought to induce neurologic detriment to the fetus. Imaging the mother for appendicitis theoretically may double the fetal risk for developing a childhood cancer. Radiation doses to the fetus from pulmonary embolus chest CT angiography are of the same magnitude as ventilation-perfusion (V/Q) scanning.

Entities:  

Mesh:

Year:  2006        PMID: 16498123     DOI: 10.2214/AJR.04.1915

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  43 in total

1.  Prenatal diagnosis of fetal skeletal dysplasia with 3D CT.

Authors:  Osamu Miyazaki; Gen Nishimura; Haruhiko Sago; Tetsuya Horiuchi; Satoshi Hayashi; Rika Kosaki
Journal:  Pediatr Radiol       Date:  2012-04-25

Review 2.  Exposing the thyroid to radiation: a review of its current extent, risks, and implications.

Authors:  Bridget Sinnott; Elaine Ron; Arthur B Schneider
Journal:  Endocr Rev       Date:  2010-07-21       Impact factor: 19.871

Review 3.  Risks to the fetus from diagnostic imaging during pregnancy: review and proposal of a clinical protocol.

Authors:  Mafalda Gomes; Alexandra Matias; Filipe Macedo
Journal:  Pediatr Radiol       Date:  2015-08-14

4.  Guidelines for diagnosis, treatment, and use of laparoscopy for surgical problems during pregnancy: this statement was reviewed and approved by the Board of Governors of the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES), September 2007. It was prepared by the SAGES Guidelines Committee.

Authors:  Hori Yumi
Journal:  Surg Endosc       Date:  2008-02-21       Impact factor: 4.584

5.  Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms.

Authors:  Di Zhang; Ali S Savandi; John J Demarco; Chris H Cagnon; Erin Angel; Adam C Turner; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

6.  Ventilation/perfusion SPECT--an essential but underrated method for diagnosis of pulmonary embolism and other diseases.

Authors:  Marika Bajc; Björn Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-31       Impact factor: 9.236

7.  EANM guidelines for ventilation/perfusion scintigraphy : Part 2. Algorithms and clinical considerations for diagnosis of pulmonary emboli with V/P(SPECT) and MDCT.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09       Impact factor: 9.236

Review 8.  Diagnosis and laparoscopic treatment of surgical diseases during pregnancy: an evidence-based review.

Authors:  Heidi Jackson; Steven Granger; Raymond Price; Michael Rollins; David Earle; William Richardson; Robert Fanelli
Journal:  Surg Endosc       Date:  2008-06-14       Impact factor: 4.584

9.  Specific absorbed fractions for internal electron emitters derived for a set of anatomically realistic reference pregnant female models.

Authors:  Bingqi Guo; X George Xu; Chengyu Shi
Journal:  Radiat Prot Dosimetry       Date:  2009-09-18       Impact factor: 0.972

10.  Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms.

Authors:  Jianwei Gu; X George Xu; Peter F Caracappa; Bob Liu
Journal:  Radiat Prot Dosimetry       Date:  2012-12-06       Impact factor: 0.972

View more