PURPOSE: To evaluate the use of pulsed high-intensity focused ultrasound exposures to improve tissue plasminogen activator (tPA)-mediated thrombolysis in an in vitro model. MATERIALS AND METHODS: All experimental work was compliant with institutional guidelines and HIPAA. Clots were formed by placing 1 mL of human blood in closed-off sections of pediatric Penrose tubes. Four experimental groups were evaluated: control (nontreated) clots, clots treated with pulsed high-intensity focused ultrasound only, clots treated with tPA only, and clots treated with pulsed high-intensity focused ultrasound plus tPA. The focused ultrasound exposures (real or sham) were followed by incubations of the clots in tPA with saline or in saline only. Thrombolysis was measured as the relative reduction in the mass of the clot. D-Dimer assays also were performed. Two additional experiments were performed and yielded dose-response curves for two exposure parameters: number of pulses per raster point and total acoustic power. Radiation force-induced displacements caused by focused ultrasound exposures were simulated in the clots. A Tukey-Kramer honestly significant difference test was performed for comparisons between all pairs of experimental groups. RESULTS: The clots treated with focused ultrasound alone did not show significant increases in thrombolysis compared with the control clots. The clots treated with focused ultrasound plus tPA showed a 50% ([30.2/20.1]/20.1) increase in the degree of thrombolysis compared with the clots treated with tPA only (P < .001), further corroborating the d-dimer assay results (P < .001). Additional experiments revealed how increasing both the number of pulses per raster point and the total acoustic power yielded corresponding increases in the thrombolysis rate. In the latter experiment, simulations performed at a range of power settings revealed a direct correlation between increased displacement and observed thrombolysis rate. CONCLUSION: The rate of tPA-mediated thrombolysis can be enhanced by using pulsed high-intensity focused ultrasound exposure in vitro. (c) RSNA, 2006.
PURPOSE: To evaluate the use of pulsed high-intensity focused ultrasound exposures to improve tissue plasminogen activator (tPA)-mediated thrombolysis in an in vitro model. MATERIALS AND METHODS: All experimental work was compliant with institutional guidelines and HIPAA. Clots were formed by placing 1 mL of human blood in closed-off sections of pediatric Penrose tubes. Four experimental groups were evaluated: control (nontreated) clots, clots treated with pulsed high-intensity focused ultrasound only, clots treated with tPA only, and clots treated with pulsed high-intensity focused ultrasound plus tPA. The focused ultrasound exposures (real or sham) were followed by incubations of the clots in tPA with saline or in saline only. Thrombolysis was measured as the relative reduction in the mass of the clot. D-Dimer assays also were performed. Two additional experiments were performed and yielded dose-response curves for two exposure parameters: number of pulses per raster point and total acoustic power. Radiation force-induced displacements caused by focused ultrasound exposures were simulated in the clots. A Tukey-Kramer honestly significant difference test was performed for comparisons between all pairs of experimental groups. RESULTS: The clots treated with focused ultrasound alone did not show significant increases in thrombolysis compared with the control clots. The clots treated with focused ultrasound plus tPA showed a 50% ([30.2/20.1]/20.1) increase in the degree of thrombolysis compared with the clots treated with tPA only (P < .001), further corroborating the d-dimer assay results (P < .001). Additional experiments revealed how increasing both the number of pulses per raster point and the total acoustic power yielded corresponding increases in the thrombolysis rate. In the latter experiment, simulations performed at a range of power settings revealed a direct correlation between increased displacement and observed thrombolysis rate. CONCLUSION: The rate of tPA-mediated thrombolysis can be enhanced by using pulsed high-intensity focused ultrasound exposure in vitro. (c) RSNA, 2006.
Authors: Kristin M Dittmar; Jianwu Xie; Finie Hunter; Cameron Trimble; Monica Bur; Victor Frenkel; King C P Li Journal: Radiology Date: 2005-03-29 Impact factor: 11.105
Authors: U Rosenschein; J J Bernstein; E DiSegni; E Kaplinsky; J Bernheim; L A Rozenzsajn Journal: J Am Coll Cardiol Date: 1990-03-01 Impact factor: 24.094
Authors: Jason M Meunier; Christy K Holland; Tyrone M Porter; Christopher J Lindsell; George J Shaw Journal: Curr Neurovasc Res Date: 2011-11 Impact factor: 1.990
Authors: David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner Journal: Med Phys Date: 2013-08 Impact factor: 4.071
Authors: Xi Zhang; Gabe E Owens; Charles A Cain; Hitinder S Gurm; Jonathan Macoskey; Zhen Xu Journal: Ultrasound Med Biol Date: 2016-05-07 Impact factor: 2.998
Authors: Vishal Saxena; Carmen Gacchina Johnson; Ayele H Negussie; Karun V Sharma; Matthew R Dreher; Bradford J Wood Journal: Int J Hyperthermia Date: 2015-03-13 Impact factor: 3.914
Authors: Sergio Dromi; Victor Frenkel; Alfred Luk; Bryan Traughber; Mary Angstadt; Monica Bur; Jason Poff; Jianwu Xie; Steven K Libutti; King C P Li; Bradford J Wood Journal: Clin Cancer Res Date: 2007-05-01 Impact factor: 12.531
Authors: Hilary Hancock; Matthew R Dreher; Nigel Crawford; Claire B Pollock; Jennifer Shih; Bradford J Wood; Kent Hunter; Victor Frenkel Journal: Clin Exp Metastasis Date: 2009-06-11 Impact factor: 5.150