Literature DB >> 9212208

Ultrasound enhancement of rabbit femoral artery thrombolysis.

P N Riggs1, C W Francis, S R Bartos, D P Penney.   

Abstract

Experiments were conducted to evaluate the potential of low-intensity, externally applied ultrasound to accelerate arterial thrombolysis in an animal model and to characterize potential effects of ultrasound exposure on vessel wall morphology. The femoral arteries of 32 rabbits were exposed, a flowprobe was positioned around the vessel, and a stenosis produced with two circumferential silk sutures to reduce flow by 50%. Thrombosis was achieved by injecting thrombin through the cannulated superficial epigastric branch into a 1-cm segment of femoral artery which was isolated for 20 min. Streptokinase was administered intravenously as a 15,000 U/kg bolus followed by an infusion of 15,000 U/kg per h. Ultrasound (1 MHz, 2 W/cm2) was delivered to the thrombosed vessel during streptokinase administration in 17 animals, and 15 control animals received sham ultrasound only. Thrombolysis occurred in nine of 17 (53%) animals receiving both streptokinase and ultrasound, and this was significantly greater than the rate in animals receiving streptokinase alone (2/15, 13%; P=0.025). Ultrasound caused a mean temperature elevation of 4 degrees C in exposed tissues. Light and electron microscopy demonstrated increased platelet accumulation on thrombi in ultrasound-treated vessels compared with controls. Endothelial cell vacuolation was seen by electron microscopy in ultrasound-exposed vessels. The results indicate that externally applied, low-intensity ultrasound can significantly enhance thrombolysis in a rabbit arterial model. Possible adverse effects are minor and include platelet accumulation, temperature elevation and minor endothelial changes. Externally applied ultrasound has potential value as an adjunct to thrombolytic therapy.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9212208     DOI: 10.1016/s0967-2109(96)00093-2

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  10 in total

1.  Cooling System Permits Effective Transcutaneous Ultrasound Clot Lysis In Vivo Without Skin Damage.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1998-09       Impact factor: 2.300

2.  Ultrasound-Enhanced Thrombolysis: EKOS EndoWave Infusion Catheter System.

Authors:  Charles A Owens
Journal:  Semin Intervent Radiol       Date:  2008-03       Impact factor: 1.513

3.  Safety Evaluation of a Forward-Viewing Intravascular Transducer for Sonothrombolysis: An in Vitro and ex Vivo Study.

Authors:  Leela Goel; Huaiyu Wu; Bohua Zhang; Jinwook Kim; Paul A Dayton; Zhen Xu; Xiaoning Jiang
Journal:  Ultrasound Med Biol       Date:  2021-08-23       Impact factor: 2.998

4.  Evaluation of ultrasound-assisted thrombolysis using custom liposomes in a model of retinal vein occlusion.

Authors:  Walid F Abdallah; Hitenkumar Patel; Edward G Grant; Bruno Diniz; Gerald J Chader; Mark S Humayun
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-10-05       Impact factor: 4.799

5.  Pulsed high-intensity focused ultrasound enhances thrombolysis in an in vitro model.

Authors:  Victor Frenkel; Jay Oberoi; Michael J Stone; Melissa Park; Cheri Deng; Bradford J Wood; Ziv Neeman; McDonald Horne; King C P Li
Journal:  Radiology       Date:  2006-02-21       Impact factor: 11.105

6.  Non-invasive low frequency vibration as a potential emergency adjunctive treatment for heart attack and stroke. An in vitro flow model.

Authors:  Fesseha G Yohannes; Andrew K Hoffmann
Journal:  J Thromb Thrombolysis       Date:  2007-05-30       Impact factor: 2.300

7.  Effect of Low-Frequency Therapeutic Ultrasound on Induction of Nitric Oxide in CKD: Potential to Prevent Acute Kidney Injury.

Authors:  Michael W Dae; Kathleen D Liu; Richard J Solomon; Dong W Gao; Carol A Stillson
Journal:  Kidney Dis (Basel)       Date:  2020-08-21

8.  Diastolic timed Vibro-Percussion at 50 Hz delivered across a chest wall sized meat barrier enhances clot dissolution and remotely administered Streptokinase effectiveness in an in-vitro model of acute coronary thrombosis.

Authors:  Andrew Hoffmann; Harjit Gill
Journal:  Thromb J       Date:  2012-11-12

9.  Effects of low frequency ultrasound on some properties of fibrinogen and its plasminolysis.

Authors:  Eugene A Cherniavsky; Igor S Strakha; Igor E Adzerikho; Vladimir M Shkumatov
Journal:  BMC Biochem       Date:  2011-11-23       Impact factor: 4.059

10.  Quantification of microbubble-induced sonothrombolysis in an ex vivo non-human primate model.

Authors:  Monica T Hinds; Azzdine Y Ammi; Jennifer Johnson; Sanjiv Kaul
Journal:  J Thromb Haemost       Date:  2020-12-23       Impact factor: 5.824

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.