Literature DB >> 16488960

Prediction of future scotoma on conventional automated static perimetry using frequency doubling technology perimetry.

S Kogure1, Y Toda, S Tsukahara.   

Abstract

AIM: To see if scotoma detected with frequency doubling technology (FDT) is confirmed by Humphrey field analyser (HFA) 3 years later.
METHODS: Subjects were first examined with the screening C-20-1 program of FDT. The visual field was examined annually for 4 years using HFA program C30-2. The central 58 test points in HFA were assigned to one of the 17 clusters corresponding to FDT test points. Each cluster was represented as the lowest probability symbol of total deviation (TD) of the HFA test points included in the cluster. Clusters were graded normal, suspected scotoma, and scotoma depending on probability of TD-5% or more, 5%-1%, less than 1%, respectively. Relative risk (RR) of abnormality on FDT for future scotoma on HFA was estimated.
RESULTS: 80 eyes of 42 patients were followed up for 4 years. While 4.0% of normal clusters of HFA with normal FDT results developed into scotoma cluster, 20.8% of normal clusters with abnormal FDT results developed into scotoma cluster with HFA at the third year. RR for future scotoma was 5.24 (95% CI, 2.75 to 10.0, p<0.05).
CONCLUSION: An abnormal result in FDT shows a high risk of future scotoma on HFA after 3 years even if the original HFA perimetry showed normal results.

Entities:  

Mesh:

Year:  2006        PMID: 16488960      PMCID: PMC1856953          DOI: 10.1136/bjo.2005.077065

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  36 in total

1.  Peripheral contrast sensitivity in glaucoma and ocular hypertension.

Authors:  F Falcão-Reis; E O'Donoghue; R Buceti; R A Hitchings; G B Arden
Journal:  Br J Ophthalmol       Date:  1990-12       Impact factor: 4.638

2.  Frequency doubling technology and confocal scanning ophthalmoscopic optic disc analysis in open-angle glaucoma with hemifield defects.

Authors:  L L Wu; Y Suzuki; S Kunimatsu; M Araie; A Iwase; G Tomita
Journal:  J Glaucoma       Date:  2001-08       Impact factor: 2.503

3.  Diagnostic capabilities of frequency-doubling technology, scanning laser polarimetry, and nerve fiber layer photographs to distinguish glaucomatous damage.

Authors:  J A Paczka; D S Friedman; H A Quigley; Y Barron; S Vitale
Journal:  Am J Ophthalmol       Date:  2001-02       Impact factor: 5.258

4.  Frequency doubling technology perimetry using a 24--2 stimulus presentation pattern.

Authors:  C A Johnson; G A Cioffi; E M Van Buskirk
Journal:  Optom Vis Sci       Date:  1999-08       Impact factor: 1.973

5.  Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage.

Authors:  Mohamed A E Soliman; Leo A M S de Jong; Al-Araby A Ismaeil; Thomas J T P van den Berg; Marc D de Smet
Journal:  Ophthalmology       Date:  2002-03       Impact factor: 12.079

6.  A frequency-doubling perimetric study in normal-tension glaucoma with hemifield defect.

Authors:  Y Kondo; T Yamamoto; Y Sato; M Matsubara; Y Kitazawa
Journal:  J Glaucoma       Date:  1998-08       Impact factor: 2.503

7.  Frequency doubling technology and high-pass resolution perimetry in glaucoma and ocular hypertension.

Authors:  Lada Kalaboukhova; Bertil Lindblom
Journal:  Acta Ophthalmol Scand       Date:  2003-06

8.  Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.

Authors:  Andreas U Bayer; Klaus-Peter Maag; Carl Erb
Journal:  Ophthalmology       Date:  2002-07       Impact factor: 12.079

9.  Frequency doubling technology perimetry abnormalities as predictors of glaucomatous visual field loss.

Authors:  Felipe A Medeiros; Pamela A Sample; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2004-05       Impact factor: 5.258

10.  Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients.

Authors:  Folkert K Horn; Nina Wakili; Anselm M Jünemann; Matthias Korth
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2002-07-05       Impact factor: 3.117

View more
  4 in total

1.  [Importance of flicker contrast tests in functional glaucoma diagnostics].

Authors:  K Göbel; C M Poloschek; C Erb; M Bach
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

2.  Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma.

Authors:  Takafumi Hirashima; Masanori Hangai; Masayuki Nukada; Noriko Nakano; Satoshi Morooka; Tadamichi Akagi; Atsushi Nonaka; Nagahisa Yoshimura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-12       Impact factor: 3.117

Review 3.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

4.  Structural and functional relationships in glaucoma using standard automated perimetry and the Humphrey Matrix.

Authors:  Seong Bae Park; Yoon Pyo Nam; Kyung Rim Sung; Michael S Kook
Journal:  Korean J Ophthalmol       Date:  2009-09-08
  4 in total