Literature DB >> 16479765

Resonance frequency analysis measurements of implants at placement surgery.

Pär-Olov Ostman1, Mats Hellman, Inger Wendelhag, Lars Sennerby.   

Abstract

PURPOSE: The knowledge of what levels of primary stability can be obtained in different jawbone regions and of what factors influence primary stability is limited. The objective of this study was to evaluate primary stability by resonance frequency analysis (RFA) measurements of implants placed according to a surgical protocol that aimed for high primary stability. The aim was also to correlate RFA measurements with factors related to the surgical technique, the patient, and implant design.
MATERIALS AND METHODS: A total of 905 Brånemark dental implants used in 267 consecutive patients were measured with RFA at the time of placement surgery.
RESULTS: A mean ISQ value of 67.4 (SD 8.6) was obtained for all implants. Univariate analyses with the implant or patient as unit showed higher ISQ values in men compared with women, in mandibles compared with maxillae, in posterior compared with anterior sites, and for wide-platform implants in comparison with regular/narrow-platform implants. There was a correlation between bone quality and primary stability, with lower ISQ values obtained for implants placed in softer bone. A lower stability was seen with increased implant length. A stepwise multiple regression analysis using the patient as unit showed that jaw type and gender had independent effects on primary stability.
CONCLUSION: The results suggest that factors related to bone density and implant diameter/length may affect the level of primary implant stability. Furthermore, greater stability was observed in male than in female patients. High primary implant stability was achieved in all jaw regions, although the use of thinner drills and/or tapered implants cannot fully compensate for the effect of soft bone. The research design does not permit conclusions regarding long-term treatment outcome with implants.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16479765

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  38 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

2.  Peri-implant osseointegration after low-level laser therapy: micro-computed tomography and resonance frequency analysis in an animal model.

Authors:  Luciano Mayer; Fernando Vacilotto Gomes; Marília Gerhardt de Oliveira; João Feliz Duarte de Moraes; Lennart Carlsson
Journal:  Lasers Med Sci       Date:  2016-08-17       Impact factor: 3.161

3.  Biomechanics and strain mapping in bone as related to immediately-loaded dental implants.

Authors:  Jing Du; Ji-Hyun Lee; Andrew T Jang; Allen Gu; Mehran Hossaini-Zadeh; Richard Prevost; Donald A Curtis; Sunita P Ho
Journal:  J Biomech       Date:  2015-06-19       Impact factor: 2.712

4.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

5.  A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables.

Authors:  Su-Young Lee; Chunmei Piao; Seong-Joo Heo; Jai-Young Koak; Joo-Hee Lee; Tae-Hyung Kim; Myung-Joo Kim; Ho-Beom Kwon; Seong-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

6.  A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis.

Authors:  In-Ho Kang; Chang-Whe Kim; Young-Jun Lim; Myung-Joo Kim
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

7.  Evaluation of stability changes in tapered and parallel wall implants: a human clinical trial.

Authors:  Ar Rokn; Aar Rasouli Ghahroudi; A Mesgarzadeh; Aa Miremadi; S Yaghoobi
Journal:  J Dent (Tehran)       Date:  2011-12-20

8.  Short Dental Implants (≤8.5 mm) versus Standard Dental Implants (≥10 mm): A One-Year Post-Loading Prospective Observational Study.

Authors:  Guillermo Pardo-Zamora; Antonio José Ortiz-Ruíz; Fabio Camacho-Alonso; José Francisco Martínez-Marco; Juan Manuel Molina-González; Núria Piqué-Clusella; Ascensión Vicente-Hernández
Journal:  Int J Environ Res Public Health       Date:  2021-05-26       Impact factor: 3.390

9.  Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size.

Authors:  Vasilena Ivanova; Ivan Chenchev; Stefan Zlatev; Eitan Mijiritsky
Journal:  Int J Environ Res Public Health       Date:  2021-06-30       Impact factor: 3.390

10.  Measurement of primary and secondary stability of dental implants by resonance frequency analysis method in mandible.

Authors:  Mehran Shokri; Arash Daraeighadikolaei
Journal:  Int J Dent       Date:  2013-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.