Literature DB >> 24551725

Effect of simulated microwave disinfection on the mechanical properties of three different types of denture base resins.

Jagadish Konchada1, Suma Karthigeyan2, Syed Asharaf Ali3, Venkateshwaran R4, Ramesh Amirisetty5, Anurag Dani6.   

Abstract

STATEMENT OF PROBLEM: Disinfection of prostheses with chemical solutions has deleterious effects on dentures. The appropriate power setting of microwave for disinfection, without affecting denture base properties, is a controversy.
PURPOSE: To evaluate and compare the effect of simulated microwave disinfection at a recommended power setting on the mechanical properties of three denture base heat polymerized acrylic resins.
MATERIAL AND METHODS: Ninety rectangular specimens of each acrylic resin of 65mm × 10mm × 3 mm dimensions were divided into three groups. Group A (Trevalon), Group B (Trevalon- HI), Group C (Ivocap). In each group, thirty specimens were divided into three subgroups with ten specimens in each and they were submitted to MicroVickers hardness, flexural strength, and impact strength tests. In each subgroup, five specimens were tested before the simulated microwave disinfection and they served as the control group. The remaining five were tested after simulated microwave disinfection and they were considered as the experimental group. Simulated microwave disinfection was done in a domestic microwave oven at 650 W for 5 minutes.
RESULTS: The data were analyzed using One-way ANOVA and t-test. The mechanical properties of the three denture base resins were not altered after simulated microwave disinfection, as compared to those of the controls.
CONCLUSION: Microwave irradiation at 650 W for 5 min did not affect the mechanical properties of the three denture base resins. Domestic microwave oven, at the prescribed setting, can be used as an alternative method of disinfection for complete dentures without affecting their properties.

Entities:  

Keywords:  Disinfection; Flexural strength; Hardness; Impact strength

Year:  2013        PMID: 24551725      PMCID: PMC3919282          DOI: 10.7860/JCDR/2013/7376.3850

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  12 in total

1.  Microwave polymerization of denture base materials. A comparative study.

Authors:  V Blagojevic; V M Murphy
Journal:  J Oral Rehabil       Date:  1999-10       Impact factor: 3.837

2.  Effectiveness of microwave sterilization on three hard chairside reline resins.

Authors:  Karin Hermana Neppelenbroek; Ana Cláudia Pavarina; Denise Madalena Palomari Spolidorio; Carlos Eduardo Vergani; Ewerton Garcia de Oliveira Mima; Ana Lúcia Machado
Journal:  Int J Prosthodont       Date:  2003 Nov-Dec       Impact factor: 1.681

3.  Effectiveness of microwave irradiation on the disinfection of complete dentures.

Authors:  Mariana Montenegro Silva; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo; Karin Hermana Neppelenbroek; Denise Madalena Palomari Spolidorio; Ana Lúcia Machado
Journal:  Int J Prosthodont       Date:  2006 May-Jun       Impact factor: 1.681

4.  Flexural strength of autopolymerizing denture reline resins with microwave postpolymerization treatment.

Authors:  Carlos Eduardo Vergani; Rosangela Seiko Seo; Ana Claudia Pavarina; Jose Mauricio dos Santos Nunes Reis
Journal:  J Prosthet Dent       Date:  2005-06       Impact factor: 3.426

5.  Effect of microwave treatments on dimensional accuracy of maxillary acrylic resin denture base.

Authors:  Sabrina Pavan; João Neudenir Arioli Filho; Paulo Henrique Dos Santos; Francisco de Assis Mollo
Journal:  Braz Dent J       Date:  2005

6.  Disinfection of denture base acrylic resin.

Authors:  J J Lin; S M Cameron; D A Runyan; D W Craft
Journal:  J Prosthet Dent       Date:  1999-02       Impact factor: 3.426

7.  The microbiologic cross-contamination of dental prostheses.

Authors:  R C Kahn; M V Lancaster; W Kate
Journal:  J Prosthet Dent       Date:  1982-05       Impact factor: 3.426

8.  Effect of microwave disinfection on physical and mechanical properties of acrylic resins.

Authors:  Rafael Leonardo Xediek Consani; Erica Brenoe Vieira; Marcelo Ferraz Mesquita; Wilson Batista Mendes; João Neudenir Arioli-Filho
Journal:  Braz Dent J       Date:  2008

9.  Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection.

Authors:  Daniela Garcia Ribeiro; Ana Cláudia Pavarina; Ana Lucia Machado; Eunice Teresinha Giampaolo; Carlos Eduardo Vergani
Journal:  Quintessence Int       Date:  2008-11       Impact factor: 1.677

10.  Microwave disinfection of complete dentures contaminated in vitro with selected bacteria.

Authors:  Lívia Nordi Dovigo; Ana Cláudia Pavarina; Daniela Garcia Ribeiro; Juliana Aparecida de Oliveira; Carlos Eduardo Vergani; Ana Lucia Machado
Journal:  J Prosthodont       Date:  2009-06-11       Impact factor: 2.752

View more
  4 in total

1.  A comparative study between microwave irradiation and sodium hypochlorite chemical disinfection: a prosthodontic view.

Authors:  Kashish Goel; Rupesh Gupta; Jitender Solanki; Meghanand Nayak
Journal:  J Clin Diagn Res       Date:  2014-04-15

Review 2.  The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview.

Authors:  Theodoros Klironomos; Aspasia Katsimpali; Gregory Polyzois
Journal:  Acta Stomatol Croat       Date:  2015-09

3.  Effect of nanoscale particles incorporation on microhardness of polymers for oral prosthesis.

Authors:  Marcelo Coelho Goiato; Bruna Carolina Rossatti Zuccolotti; Amalia Moreno; Aljomar José Vechiato Filho; Marcela Borghi Paulini; Daniela Micheline Dos Santos
Journal:  Contemp Clin Dent       Date:  2016 Jul-Sep

4.  Effect of Repeated Microwave Disinfection on the Surface Hardness of a Heat-Cured Denture Base Resin: An In vitro Study.

Authors:  Priti Jaiswal; Neelam Pande; Rajlakshmi Banerjee; Usha Radke
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.