| Literature DB >> 16446910 |
Carlos Eduardo Nazareth Nigro1, Josiane Faria de Aguiar Nigro, Richard Louis Voegels, Olavo Mion, João Ferreira Mello Junior.
Abstract
UNLABELLED: The graphic obtained by acoustic rhinometry in Caucasian adult individuals with no nasal affections clearly shows two notches at the beginning of the nasal echogram. However, there are controversies in the literature concerning their anatomic correlation. AIM: The aim of this study was to obtain data that would contribute to the anatomic correlation of these two notches. STUDYEntities:
Mesh:
Year: 2005 PMID: 16446910 PMCID: PMC9450530 DOI: 10.1016/s1808-8694(15)31303-3
Source DB: PubMed Journal: Braz J Otorhinolaryngol ISSN: 1808-8686
Figure 1Diagram of anterior nasal portion.
Figure 2APhotography of nasal valve in baseline conditions.
Figure 2BPhotography of opening of nasal valve occluded by cotton ball soaked in liquid Vaseline.
Figure 2CPhotography of nasal valve after nasal topical vasoconstrictor.
Figure 3ARhinograms of a typical case (subject n. 6): 1. Baseline conditions (red); 2. with occlusion of nasal valve (pink); 3. after use of nasal decongestant without occlusion of nasal valve (blue).
Figure 4Changes to ASTM1. Baseline conditions (red circles); after obstruction of nasal valve (pink triangle) and after decongestion (blue squares).
Figure 5Changes to ASTM2. Baseline conditions (red circles); after obstruction of nasal valve (pink triangles) and after decongestion (blue squares).
Mean, amplitude and statistical comparison of ASTM1 and ASTM2 at baseline condition, after occlusion of nasal valve and after nasal topical vasoconstrictor.
| baseline condition | NV obstruction | VC after | statistical comparison | |
|---|---|---|---|---|
| MCA 1 | 0.70 ± 0.10 | 0.71 ± 0.12 | 0.68 ± 0.11 | ns |
| (cm2) | 0.52 - 0.88 | 0.47 - 0.94 | 0.48 - 0.95 | ns |
| MCA 2 | 0.60 ± 0.15 | 0.32 ± 0.14 | 0.78 ± 0.17 | p < 0.001 |
| (cm2) | 0.38 - 0.91 | 0.12 - 0.62 | 0.48 - 1.15 | p < 0.001 |
dp: standard deviation VC: nasal topical vasoconstrictor NV: nasal valve Analysis of variance:
baseline x occlusion NV
baseline x post-VC
Means, amplitudes and statistical comparison of DASTM1 and DASTM2 in baseline condition, after occlusion of nasal valve and after nasal topical vasoconstrictor.
| baseline condition | NV obstruction | VC after | statistical comparison | |
|---|---|---|---|---|
| DMCA 1 | 0.28 ± 0.12 | 0.28 ± 0.12 | 0.28 ± 0.12 | ns |
| (cm) | 0.18 - 0.42 | 0.18 - 0.42 | 0.18 - 0.42 | ns |
| DMCA 2 | 1.93 ± 0.14 | 2.15 ± 0.25 | 1.85 ± 0.24 | p < 0.001 |
| (cm) | 1.62 - 2.10 | 1.86 - 2.82 | 1.38 - 2.86 | ns |
dp: standard deviation
VC: nasal topical vasoconstrictor
NV: nasal valve
Analysis of variance:
baseline x occlusion VN
baseline x post-VC