HemoCue: evaluation of a portable photometric system for determining glucose in whole blood.

L Ashworth1, I Gibb, K G Alberti.   

Abstract

We assessed the HemoCue system for measuring glucose in 5 microL of whole blood. A glucose dehydrogenase-based reaction is used with dried reagents contained in disposable microcuvettes, which are filled with blood by capillary action. Automated hexokinase and YSI 23AM glucose analyzer methods were used for comparison. Overall imprecision (CV) was better than 4.5%, with no significant differences in results between three different HemoCue photometers and four batches of microcuvettes. Regression slopes (+/- SE) were 0.947 (0.011) with the YSI and 0.966 (0.015) with the hexokinase method. Analytical recovery of added glucose was 101-106%, and the system functioned with hematocrits up to 0.65. Bilirubin up to 453 mumol/L did not interfere, but high concentrations of endogenous (greater than 3 mmol/L) and exogenous triglycerides gave positive interference. The system proved stable and robust under a wide range of storage and handling conditions; performance was impaired only at high ambient temperature (37 degrees C). We conclude that the HemoCue system should prove useful for glucose measurement; further testing outside the laboratory is warranted.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1643718

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  8 in total

Review 1.  Accuracy of point-of-care glucose measurements.

Authors:  Annette Rebel; Mark A Rice; Brenda G Fahy
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Comparison of two cotside methods for the detection of hypoglycaemia among neonates in Nepal.

Authors:  M Ellis; D S Manandhar; N Manandhar; J M Land; N Patel; A M de L Costello
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-09       Impact factor: 5.747

3.  Measuring blood glucose in neonatal units: how does hemocue compare?

Authors:  S A Deshpande; J N Matthews; M P Platt
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-11       Impact factor: 5.747

4.  Evaluation of the VIA Blood Chemistry Monitor for Glucose in Healthy and Diabetic Volunteers.

Authors:  Arjunan Ganesh; Brian Hipszer; Navdeep Loomba; Barbara Simon; Marc C Torjman; Jeffrey Joseph
Journal:  J Diabetes Sci Technol       Date:  2008-03

5.  Insulin concentrations and insulin sensitivity after short-term amiloride in healthy subjects.

Authors:  J W Eriksson; J Fowelin; V Urbanavicius
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

6.  Effects of Nordic walking on health-related quality of life in overweight individuals with type 2 diabetes mellitus, impaired or normal glucose tolerance.

Authors:  T Fritz; K Caidahl; M Osler; C G Ostenson; J R Zierath; P Wändell
Journal:  Diabet Med       Date:  2011-11       Impact factor: 4.359

7.  Risk factors of impaired fasting glucose and type 2 diabetes in Yaoundé, Cameroon: a cross sectional study.

Authors:  Clement Nyuyki Kufe; Kerstin Klipstein-Grobusch; Fezeu Leopold; Felix Assah; George Ngufor; George Mbeh; Vivian Nchanchou Mbanya; Jean Claude Mbanya
Journal:  BMC Public Health       Date:  2015-01-31       Impact factor: 3.295

Review 8.  From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics).

Authors:  Dionysios C Christodouleas; Balwinder Kaur; Parthena Chorti
Journal:  ACS Cent Sci       Date:  2018-11-20       Impact factor: 14.553

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.