Literature DB >> 8976688

Measuring blood glucose in neonatal units: how does hemocue compare?

S A Deshpande1, J N Matthews, M P Platt.   

Abstract

Rapid and reliable determination of blood glucose concentration is essential during the neonatal period to prevent adverse neurodevelopmental outcome from hypoglycaemia. Despite their unreliability, reagent strip methods continue to be used extensively in neonatal nurseries due to their rapidity and convenience. Recently, a new portable laboratory standard technique has been introduced (HemoCue B-Glucose system) for whole blood glucose determination. It is particularly suitable for near-patient testing in neonatal units. This new method, as well as other established methods of whole blood (Yellow Springs Instrument (YSI) and a hexokinase method on Cobas Bio), and plasma (Kodak Ektachem) glucose measurement, were therefore evaluated for their accuracy and concordance of measurements taken in the neonatal period. There were substantial discrepancies among the four methods of glucose measurement with wide limits of agreement between these methods. The glucose concentrations measured by HemoCue and YSI (n = 206), HemoCue and hexokinase (n = 113), HemoCue and plasma glucose on Ektachem (n = 69) and hexokinase and Ektachem (n = 66) were likely to differ by -29 to +61%, -23 to +56%, -36 to +65%, and -19 to +30%, respectively. Even the laboratory methods of blood glucose determination, therefore, can not be used interchangeably. Using a model based approach, the probabilities of "discordant" classification as hypo- or normo-glycaemia were estimated to be 6.8%, 6.5%, and 7.1% between HemoCue and YSI, HemoCue and hexokinase on Cobas Bio, and HemoCue and Ektachem analysers, respectively. In view of these low probabilities of discordant classification with other glucose analysers, the HemoCue system may offer a reasonable compromise between bedside and laboratory blood glucose estimations in neonates.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8976688      PMCID: PMC1061201          DOI: 10.1136/fn.75.3.f202

Source DB:  PubMed          Journal:  Arch Dis Child Fetal Neonatal Ed        ISSN: 1359-2998            Impact factor:   5.747


  29 in total

1.  Letter: Effect of skin-cleaning agents on Dextrostix readings.

Authors:  S G Ball; A S Hughes
Journal:  Br Med J       Date:  1976-05-22

2.  Adverse neurodevelopmental outcome of moderate neonatal hypoglycaemia.

Authors:  A Lucas; R Morley; T J Cole
Journal:  BMJ       Date:  1988-11-19

3.  Hyperviscosity in the neonate.

Authors:  G P Gross; W E Hathaway; H R McGaughey
Journal:  J Pediatr       Date:  1973-06       Impact factor: 4.406

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974).

Authors:  R B Passey; R L Gillum; J B Fuller; F M Urry; M L Giles
Journal:  Clin Chem       Date:  1977-01       Impact factor: 8.327

6.  A clinical audit of cotside blood glucose measurement in the detection of neonatal hypoglycaemia.

Authors:  G J Reynolds; S Davies
Journal:  J Paediatr Child Health       Date:  1993-08       Impact factor: 1.954

7.  School performance of children with birth weights of 1,000 g or less.

Authors:  R E Nickel; F C Bennett; F N Lamson
Journal:  Am J Dis Child       Date:  1982-02

8.  Incidence of neonatal hyperviscosity at sea level.

Authors:  K Stevens; F H Wirth
Journal:  J Pediatr       Date:  1980-07       Impact factor: 4.406

9.  Neonatal hyperviscosity: I. Incidence.

Authors:  F H Wirth; K E Goldberg; L O Lubchenco
Journal:  Pediatrics       Date:  1979-06       Impact factor: 7.124

10.  Erroneously high Dextrostix values caused by isopropyl alcohol.

Authors:  D M Grazaitis; W R Sexson
Journal:  Pediatrics       Date:  1980-08       Impact factor: 7.124

View more
  1 in total

1.  Comparison of Point of Care (POC) Testing of Glucose by B Braun Glucometer and Hemocue Glucose 201+ Analyser Versus Centralised Testing in Neonatal Intensive Care Unit (NICU).

Authors:  Sudha Reddy V R; Sumathi M E; Beere Gowda Y C; Mohamed Suhail S
Journal:  J Clin Diagn Res       Date:  2014-07-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.