PURPOSE: The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T.
MATERIAL AND METHODS: Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Systems) and at a 3.0 T MR system. Imaging delayed contrast enhancement was started 10 minutes after application of contrast material. A phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence was used at 1.5 and 3.0 T and compared with a segmented IR turboFLASH sequence at 1.5 T, which served as the reference method. Infarct volumes and CNR of infarction and normal myocardium were compared with the reference method.
RESULTS: The PSIR Single-Shot TrueFISP technique allows for imaging nine slices during a single breathhold without adaptation of the inversion time. The mean value of CNR between infarction and normal myocardium was 5.9 at 1.5 T and 12.2 at 3.0 T (magnitude images). The CNR mean value of the reference method was 8.4. The CNR mean value at 3.0 T was significantly (P = 0.03) higher than the mean value of the reference method. The correlation coefficients of the infarct volumes, determined with the PSIR single-shot TrueFISP technique at 1.5 T and at 3.0 T and compared with the reference method, were r = 0.96 (P = 0.001) and r = 0.99 (P = 0.0001).
CONCLUSION: The use of PSIR single-shot TrueFISP at 3.0 T allows for accurate detection and assessment of myocardial infarction. CNR is significantly higher at 3.0 T compared with 1.5 T. The PSIR single-shot technique at 3.0 T provides a higher CNR than the segmented reference technique at 1.5 T.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16428986     DOI: 10.1097/01.rli.0000195843.97582.f4

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  16 in total

Review 1.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

2.  Intraindividual comparison of myocardial delayed enhancement MR imaging using gadobenate dimeglumine at 1.5 T and 3 T.

Authors:  Bernhard D Klumpp; Joern Sandstede; Klaus P Lodemann; Achim Seeger; Tobias Hoevelborn; Michael Fenchel; Ulrich Kramer; Claus D Claussen; Stephan Miller
Journal:  Eur Radiol       Date:  2008-12-18       Impact factor: 5.315

3.  [Cardiac magnetic resonance imaging: from imaging to diagnosis].

Authors:  M Gutberlet
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

Review 4.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

Review 5.  Important advances in technology and unique applications related to cardiac magnetic resonance imaging.

Authors:  Mohamad G Ghosn; Dipan J Shah
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

6.  [Late gadolinium enhancement in the diagnostics of ischemic heart disease: technical principles, contrast optimization and clinical application].

Authors:  K U Bauner; A Biffar; M Greif; A Becker; M Picciolo; D Theisen; T A Sandner; M Notohamiprodjo; M F Reiser; B J Wintersperger
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

Review 7.  Cardiac imaging techniques for physicians: late enhancement.

Authors:  Peter Kellman; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2012-09       Impact factor: 4.813

8.  Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

Authors:  Rajiv G Menon; G Wilson Miller; Jean Jeudy; Sanjay Rajagopalan; Taehoon Shin
Journal:  Magn Reson Med       Date:  2016-04-28       Impact factor: 4.668

9.  Inversion-recovery single-shot cardiac MRI for the assessment of myocardial infarction at 1.5 T with a dedicated cardiac coil.

Authors:  M Wildgruber; M Settles; K Herrmann; A J Beer; E J Rummeny; A M Huber
Journal:  Br J Radiol       Date:  2012-09       Impact factor: 3.039

Review 10.  [Screening in cardiovascular diseases].

Authors:  H Kramer; S Weckbach; G van Kaick; M F Reiser; S O Schoenberg
Journal:  Radiologe       Date:  2008-01       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.