Abstract

BACKGROUND: The purpose of this study was to identify patient subgroups in which prosthesis-patient mismatch most influenced late survival.
METHODS: Over a 12-year period, 1,400 consecutive patients underwent bioprosthetic (933 patients) or mechanical (467) aortic valve replacement. Prosthesis-patient mismatch was defined as prosthetic effective orifice area/body surface area less than 0.75 cm2/m2 and was present with 11% mechanical and 51% bioprosthetic valves.
RESULTS: With bioprosthetic valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 68% +/- 7% mismatch versus 75% +/- 7% no mismatch, p < 0.02) but not older patients (p = 0.47). Similarly, with mechanical valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 62% +/- 11% versus 79% +/- 4%, p < 0.005) but not older patients (p = 0.26). For small patients (body surface area less than 1.7 m2), prosthesis-patient mismatch did not impact survival with bioprosthetic (p = 0.32) or mechanical (p = 0.71) valves. For average-size patients (body surface area 1.7 to 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with both bioprosthetic (p < 0.05) and mechanical (p < 0.005) valves. For large patients (body surface area greater than 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with mechanical (p < 0.04) but not bioprosthetic (p = 0.40) valves.
CONCLUSIONS: Prosthesis-patient mismatch had a negative impact on survival for young patients, but its impact on older patients was minimal. In addition, although prosthesis-patient mismatch was not important in small patients, prosthesis-patient mismatch negatively impacted survival for average-size patients and for large patients with mechanical valves.

Entities:  

Mesh:

Year:  2006        PMID: 16427836     DOI: 10.1016/j.athoracsur.2005.07.084

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  21 in total

1.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

2.  Aortic valve annular dimension in Indian population.

Authors:  Hannah Sugirthabai Rajila Rajendran; Sudha Seshayyan; Ashok Victor; Gangadevi Rajapandian
Journal:  J Clin Diagn Res       Date:  2013-09-10

3.  Early and late outcomes of AVR with aortic annular enlargement in octogenarian.

Authors:  Yuki Okamoto; Kazuo Yamamoto; Tsutomu Sugimoto; Shinpei Yoshii
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-05-14

4.  Factors affecting survival after mitral valve replacement in patients with prosthesis-patient mismatch.

Authors:  Abdulhameed Aziz; Jennifer S Lawton; Hersh S Maniar; Michael K Pasque; Ralph J Damiano; Marc R Moon
Journal:  Ann Thorac Surg       Date:  2010-10       Impact factor: 4.330

5.  Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Takashi Iwata; Keikou Tei; Takuya Miura
Journal:  Heart Vessels       Date:  2012-11-17       Impact factor: 2.037

Review 6.  Narrative review of the contemporary surgical treatment of unicuspid aortic valve disease.

Authors:  Maria von Stumm; Tatjana Sequeira-Gross; Johannes Petersen; Shiho Naito; Lisa Müller; Christoph Sinning; Evaldas Girdauskas
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

7.  Small prosthesis size in aortic valve replacement does not affect mortality.

Authors:  Damien J LaPar; Gorav Ailawadi; Castigliano M Bhamidipati; George Stukenborg; Ivan K Crosby; John A Kern; Irving L Kron
Journal:  Ann Thorac Surg       Date:  2011-09       Impact factor: 4.330

Review 8.  Update on aortic valve prosthesis-patient mismatch in Japan.

Authors:  Yoshimasa Sakamoto; Kazuhiro Hashimoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-04-13

9.  Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression.

Authors:  Yasuyuki Kato; Yasushi Tsutsumi; Takahiro Kawai; Tomoyuki Goto; Yosuke Takahashi; Hirokazu Ohashi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-08-13

10.  Patient-prosthesis mismatch after aortic valve replacement in the elderly.

Authors:  Masaaki Ryomoto; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Yasuhiko Kobayashi; Shinya Fukui; Noriko Tsujiya; Tetsuya Kajiyama; Yuji Miyamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2008-07-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.