Preprocessing, binning and dataset subsampling are investigated with regard to simultaneous maximisation of the speed, accuracy and robustness of CT-3D rotational angiography (3DRA) registration. Clinical diagnosis and treatment can both take advantage of this integration, because 3DRA allows the shape of vessel structures to be evaluated three-dimensionally with respect to standard 2D projective angiography. The method for optimising preprocessing, binning and subsampling consisted of independent variation of the corresponding parameters to maximise robustness and speed while maintaining subvoxel accuracy; the latter was computed as the sum of the mean squared errors initially present in the registrations with the errors relative to both binning and subsampling. The results suggest the choice of 256 bins, steps between 14 mm (coarse optimisation) and 2.5 mm (fine optimisation) and bone segmentation by threshold, for binning, subsampling and preprocessing, respectively. The application of this parameter set-up to 50 CT-3DRA registrations resulted in a saving, on average, of 40% of the time with respect to the method previously used, while registration error was maintained within 2 mm (1.97 mm, 90% confidence interval) and robustness was increased, so that no manual initial realignment was needed in 48 registrations. Validation by the registration of images acquired for a head phantom showed subvoxel residual errors. In conclusion, the proposed procedure can be considered a satisfactory strategy to optimise CT-3DRA registration.

Entities:  

Mesh:

Year:  2005        PMID: 16411640     DOI: 10.1007/BF02351041

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   3.079


  15 in total

1.  Development of rotational digital angiography and new cone-beam 3D image: clinical value in vascular lesions.

Authors:  T Kumazaki
Journal:  Comput Methods Programs Biomed       Date:  1998 Aug-Sep       Impact factor: 5.428

2.  3D-CT angiography of cerebral arteriovenous malformations.

Authors:  S Aoki; Y Sasaki; T Machida; N Hayashi; I Shirouzu; T Ohkubo; A Terahara; Y Sasaki; S Kawamoto; T Araki; T Maehara
Journal:  Radiat Med       Date:  1998 Jul-Aug

3.  Second-generation three-dimensional reconstruction for rotational three-dimensional angiography.

Authors:  L M Bidaut; C Laurent; M Piotin; P Gailloud; M Muster; J H Fasel; D A Rüfenacht; F Terrier
Journal:  Acad Radiol       Date:  1998-12       Impact factor: 3.173

Review 4.  Failure in radiosurgery treatment of cerebral arteriovenous malformations.

Authors:  P Gallina; L Merienne; J F Meder; M Schlienger; D Lefkopoulos; J J Merland
Journal:  Neurosurgery       Date:  1998-05       Impact factor: 4.654

5.  Matching PET and CT scans of the head and neck area: development of method and validation.

Authors:  Bianca M Klabbers; Jan C de Munck; Ben J Slotman; Hans A Langendijk; Remco de Bree; Otto S Hoekstra; Ronald Boellaard; Adriaan A Lammertsma
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

6.  Compartments in arteriovenous malformation nidi demonstrated with rotational three-dimensional digital subtraction angiography by using selective microcatheterization. Report of three cases.

Authors:  Yukinari Kakizawa; Hisashi Nagashima; Fusakazu Oya; Kiyoshi Ito; Yuichiro Tanaka; Kazuhiro Hongo; Shigeaki Kobayashi
Journal:  J Neurosurg       Date:  2002-04       Impact factor: 5.115

7.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms.

Authors:  Takeshi Sugahara; Yukunori Korogi; Kouji Nakashima; Satoshi Hamatake; Shin Honda; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

8.  Image-guided robotic radiosurgery

Authors: 
Journal:  Neurosurgery       Date:  1999-06       Impact factor: 4.654

9.  CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study.

Authors:  M Piotin; P Gailloud; L Bidaut; S Mandai; M Muster; J Moret; D A Rüfenacht
Journal:  Neuroradiology       Date:  2003-04-26       Impact factor: 2.804

10.  Three-dimensional angiography for radiosurgical treatment planning for arteriovenous malformations.

Authors:  Federico Colombo; Carlo Cavedon; Paolo Francescon; Leopoldo Casentini; Umberto Fornezza; Lucio Castellan; Francesco Causin; Stefano Perini
Journal:  J Neurosurg       Date:  2003-03       Impact factor: 5.115

View more
  1 in total

1.  A multi-metric registration strategy for the alignment of longitudinal brain images in pediatric oncology.

Authors:  Eros Montin; Antonella Belfatto; Marco Bologna; Silvia Meroni; Claudia Cavatorta; Emilia Pecori; Barbara Diletto; Maura Massimino; Maria Chiara Oprandi; Geraldina Poggi; Filippo Arrigoni; Denis Peruzzo; Emanuele Pignoli; Lorenza Gandola; Pietro Cerveri; Luca Mainardi
Journal:  Med Biol Eng Comput       Date:  2020-02-11       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.