Literature DB >> 10371630

Image-guided robotic radiosurgery

.   

Abstract

PURPOSE: To describe the design and performance of a novel frameless system for radiosurgery. This technology, called image-guided radiosurgery (IGR), eliminates the need for stereotactic frame fixation by relating the identified lesion to radiographic landmarks. CONCEPT: IGR uses a lightweight x-band linear accelerator, computer-controlled robotic arm (Fanuc manipulator [Fanuc Robotics North America, Inc., Rochester Hills, MI]), paired orthogonal x-ray imagers, and a computer workstation that performs rapid image-to-image registration. During radiosurgery, the x-ray imaging system determines the location of the lesion and communicates these coordinates to the robot, which adjusts the pointing of the linear accelerator beam to maintain alignment with the target. RATIONALE: Existing stereotactic techniques require rigid cranial fixation to establish and maintain a system of reference for targeting. Such frames cause pain for the patient, limit the use of fractionation, and necessitate a prolonged period of general anesthesia if children are to be treated. Furthermore, skeletal or any other type of rigid fixation is difficult to achieve beyond the cranium. IGR was designed to overcome these limitations, which are inherent to nearly all current radiosurgical methods. DISCUSSION: Preliminary testing and early clinical experience have demonstrated the practicality and potential of the IGR concept and have identified the most important directions for improvement. For example, an IGR prototype accurately tracked target displacements in three dimensions but showed reduced accuracy when confronted by rotational movements. This observation led to development of a new generation of tracking algorithm that promises to improve tracking in all six dimensions. Further experience indicated that improvements in the quality of the x-ray images were needed to allow the system to locate and treat target sites outside the cranium. Consequently, a new x-ray imaging technology with superior resolution and increased sensitivity has been added to the system. These improvements should make it possible to apply IGR techniques to a variety of targets located throughout the body. This article describes and critiques the components of the IGR and summarizes our preliminary clinical experience.

Entities:  

Year:  1999        PMID: 10371630

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  53 in total

Review 1.  Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

Authors:  Yohannes Kassahun; Bingbin Yu; Abraham Temesgen Tibebu; Danail Stoyanov; Stamatia Giannarou; Jan Hendrik Metzen; Emmanuel Vander Poorten
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-08       Impact factor: 2.924

Review 2.  Interventional robotic systems: applications and technology state-of-the-art.

Authors:  Kevin Cleary; Andreas Melzer; Vance Watson; Gernot Kronreif; Dan Stoianovici
Journal:  Minim Invasive Ther Allied Technol       Date:  2006       Impact factor: 2.442

3.  New frontiers in radiosurgery for the brain and body.

Authors:  Cole A Giller; Brian D Berger
Journal:  Proc (Bayl Univ Med Cent)       Date:  2005-10

4.  Pulmonary fissure segmentation on CT.

Authors:  Jingbin Wang; Margrit Betke; Jane P Ko
Journal:  Med Image Anal       Date:  2006-06-27       Impact factor: 8.545

Review 5.  The evolution and future of minimalism in neurological surgery.

Authors:  Charles Y Liu; Michael Y Wang; Michael L J Apuzzo
Journal:  Childs Nerv Syst       Date:  2004-07-30       Impact factor: 1.475

6.  Rotational and translational reproducibility of newly developed Leksell frame-based relocatable fixation system.

Authors:  Etsuo Kunieda; Hossain M Deloar; Masayuki Kitamura; Osamu Kawaguchi; Hideyuki Shiba; Atsuya Takeda; Takatsugu Kawase; Satoshi Seki; Naoyuki Shigematsu; Atsushi Kubo
Journal:  Radiat Med       Date:  2006-08

7.  Efficacy and safety of CyberKnife radiosurgery for acromegaly.

Authors:  Brian K Roberts; Daniel L Ouyang; Shivanand P Lad; Steven D Chang; Griffith R Harsh; John R Adler; Scott G Soltys; Iris C Gibbs; Lynn Remedios; Laurence Katznelson
Journal:  Pituitary       Date:  2007       Impact factor: 4.107

8.  Paragangliomas of head and neck: a treatment option with CyberKnife radiosurgery.

Authors:  Livia C Bianchi; Marcello Marchetti; Lorenzo Brait; Achille Bergantin; Ida Milanesi; Giovanni Broggi; Laura Fariselli
Journal:  Neurol Sci       Date:  2009-09-23       Impact factor: 3.307

9.  Radiosurgery for recurrent brain metastases after whole-brain radiotherapy : factors affecting radiation-induced neurological dysfunction.

Authors:  Ho-Shin Gwak; Hyung Jun Yoo; Sang-Min Youn; Dong Han Lee; Mi Sook Kim; Chang Hun Rhee
Journal:  J Korean Neurosurg Soc       Date:  2009-05-31

10.  CyberKnife: A new paradigm in radiotherapy.

Authors:  Gopalakrishna Kurup
Journal:  J Med Phys       Date:  2010-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.