Literature DB >> 16405899

New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

Kazufusa Shinomiya1, Kazuhiro Yanagidaira, Yoichiro Ito.   

Abstract

The cross-axis coil planet centrifuge (X-axis CPC) is useful for partitioning macromolecules with aqueous-aqueous polymer phase systems. The floor model we have built with a pair of separation columns had some shortcomings such as requirement of large space, short life of the flow tubes, and difficulty in installing columns. In order to improve the partition efficiency and the utility of counter-current chromatography (CCC), a new small-scale X-axis CPC was designed and fabricated in our laboratory. The down-sizing of the apparatus was done by reducing the scale to about 1/2 of our original model of X-1.5L type with several improvements. Performance of the apparatus was evaluated on protein separation using an aqueous-aqueous polymer phase system composed of polyethylene glycol 1000 and dibasic potassium phosphate with four multilayer coiled columns. A series of experiments revealed that the combination of right- and left-handed coils produced the best partition efficiencies for both lower and upper mobile phases by selecting the revolution direction. The overall results indicate that the head-tail elution mode substantially affects to the peak resolution and stationary phase retention. This new X-axis CPC would be useful for the separation of various kinds of biologically active compounds.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16405899     DOI: 10.1016/j.chroma.2005.12.046

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  9 in total

1.  Improved Separations of Proteins and Sugar Derivatives Using the Small-Scale Cross-Axis Coil Planet Centrifuge with Locular Multilayer Coiled Columns.

Authors:  Kazufusa Shinomiya; Motoki Umezawa; Manami Seki; Jun Nitta; Kazumasa Zaima; Naoki Harikai; Yoichiro Ito
Journal:  Separations       Date:  2016-09-22

2.  Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Kazuya Nakagomi; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2011-01       Impact factor: 1.312

3.  New analytical spiral tube assembly for separation of proteins by counter-current chromatography.

Authors:  Xiaofeng Ma; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2015-05-28       Impact factor: 4.759

4.  Design of a coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with polar organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Koji Tokura; Emiru Kimura; Midori Takai; Naoki Harikai; Kazunori Yoshida; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2015-03-12       Impact factor: 4.759

5.  Partition efficiencies of three different coiled columns for the coil satellite centrifuge at higher rotation speed combinations.

Authors:  Kazufusa Shinomiya; Kazumasa Zaima; Miho Yasue; Rika Honda; Yoshiyuki Sakuma; Naoki Harikai; Koji Tokura; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2019-03-06       Impact factor: 4.759

6.  Countercurrent chromatographic separation of proteins using an eccentric coiled column with synchronous and nonsynchronous type-J planetary motions.

Authors:  Kazufusa Shinomiya; Kazunori Yoshida; Koji Tokura; Etsuhiro Tsukidate; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  Anal Sci       Date:  2015       Impact factor: 2.081

7.  Countercurrent chromatographic separation and purification of various ribonucleases using a small-scale cross-axis coil planet centrifuge with aqueous-aqueous polymer phase systems.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Naomi Motoyoshi; Norio Inokuchi; Kazuya Nakagomi; Yoichiro Ito
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-02-24       Impact factor: 3.205

8.  Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Kazuki Sato; Kazunori Yoshida; Koji Tokura; Hiroshi Maruyama; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2013-11-05       Impact factor: 4.759

9.  PARTITION EFFICIENCY OF NEWLY DESIGNED LOCULAR MULTILAYER COIL FOR COUNTERCURRENT CHROMATOGRAPHIC SEPARATION OF PROTEINS USING SMALL-SCALE CROSS-AXIS COIL PLANET CENTRIFUGE WITH AQUEOUS-AQUEOUS POLYMER PHASE SYSTEMS.

Authors:  Kazufusa Shinomiya; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2009-01-01       Impact factor: 1.312

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.