Literature DB >> 19272844

Countercurrent chromatographic separation and purification of various ribonucleases using a small-scale cross-axis coil planet centrifuge with aqueous-aqueous polymer phase systems.

Kazufusa Shinomiya1, Hiroko Kobayashi, Naomi Motoyoshi, Norio Inokuchi, Kazuya Nakagomi, Yoichiro Ito.   

Abstract

Countercurrent chromatographic (CCC) separation and purification of various ribonucleases (RNases) was performed using the small-scale cross-axis coil planet centrifuge (X-axis CPC) with aqueous-aqueous polymer phase systems. RNases B and A were well resolved from each other with an aqueous-aqueous polymer phase system composed of 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate (pH 9.2) as the mobile lower phase. The commercial RNase A samples obtained from three different companies were also highly purified using the 16.0% (w/w) PEG 1000-6.3% (w/w) dibasic potassium phosphate-6.3% (w/w) monobasic potassium phosphate system (pH 6.6) using the upper phase as the mobile phase. Recombinant RNase Po(1), an RNase T(1) family enzyme, was further successfully separated from the crude extract using the same solvent system with the lower phase used as the mobile phase. The RNase activities were well preserved during the CCC separation. The overall results demonstrate that the small-scale X-axis CPC is useful for a simple and rapid purification of various RNases in a preparative-scale.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19272844      PMCID: PMC2745059          DOI: 10.1016/j.jchromb.2009.02.038

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  8 in total

1.  New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

Authors:  Kazufusa Shinomiya; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2006-01-06       Impact factor: 4.759

2.  Cleavage of structural proteins during the assembly of the head of bacteriophage T4.

Authors:  U K Laemmli
Journal:  Nature       Date:  1970-08-15       Impact factor: 49.962

3.  The amino acid sequence of ribonuclease T-1.

Authors:  K Takahashi
Journal:  J Biol Chem       Date:  1965-10       Impact factor: 5.157

4.  Isolation and properties of a ribonuclease from Aspergillus saitoi.

Authors:  M Irie
Journal:  J Biochem       Date:  1967-11       Impact factor: 3.387

5.  Purification and primary structure of a new guanylic acid specific ribonuclease from Pleurotus ostreatus.

Authors:  H Nomura; N Inokuchi; H Kobayashi; T Koyama; M Iwama; K Ohgi; M Irie
Journal:  J Biochem       Date:  1994-07       Impact factor: 3.387

6.  New small-scale cross-axis coil planet centrifuge. Partition efficiency and application to purification of bullfrog ribonuclease.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Koji Kobayashi; Hisashi Oshima; Susumu Kitanaka; Kazuhiro Yanagidaira; Haruo Sasaki; Minoru Muto; Michiharu Okano; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2007-03-16       Impact factor: 4.759

7.  The Rana catesbeiana rcr gene encoding a cytotoxic ribonuclease. Tissue distribution, cloning, purification, cytotoxicity, and active residues for RNase activity.

Authors:  H C Huang; S C Wang; Y J Leu; S C Lu; Y D Liao
Journal:  J Biol Chem       Date:  1998-03-13       Impact factor: 5.157

8.  Measurement of protein using bicinchoninic acid.

Authors:  P K Smith; R I Krohn; G T Hermanson; A K Mallia; F H Gartner; M D Provenzano; E K Fujimoto; N M Goeke; B J Olson; D C Klenk
Journal:  Anal Biochem       Date:  1985-10       Impact factor: 3.365

  8 in total
  3 in total

1.  Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Kazuya Nakagomi; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2011-01       Impact factor: 1.312

2.  Countercurrent chromatographic separation of proteins using an eccentric coiled column with synchronous and nonsynchronous type-J planetary motions.

Authors:  Kazufusa Shinomiya; Kazunori Yoshida; Koji Tokura; Etsuhiro Tsukidate; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  Anal Sci       Date:  2015       Impact factor: 2.081

3.  Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Kazuki Sato; Kazunori Yoshida; Koji Tokura; Hiroshi Maruyama; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2013-11-05       Impact factor: 4.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.