Literature DB >> 30862407

Partition efficiencies of three different coiled columns for the coil satellite centrifuge at higher rotation speed combinations.

Kazufusa Shinomiya1, Kazumasa Zaima2, Miho Yasue2, Rika Honda2, Yoshiyuki Sakuma2, Naoki Harikai2, Koji Tokura3, Yoichiro Ito4.   

Abstract

The partition efficiencies of three different coiled columns, conventional multilayer coiled column, eccentric coiled column and toroidal coiled column, were evaluated by the separation of 4-methylumbelliferyl sugar derivatives using the coil satellite centrifuge (CSC) with an organic-aqueous two-phase solvent system composed of ethyl acetate/1-butanol/water. The CSC apparatus was reinforced the planet axis to maintain the stable satellite motion, which was completed by combining the rotation of three axes including the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (ω3) under the relation at ω1 = ω2 + ω3. In the present study, four different rotation speed combination types were used for the separation at the ratio (ω1, ω2, ω3) = I. (300, 150, 150), II. (300, 100, 200), III. (300, 147, 153) and IV. (300, 200, 100 rpm) under different revolution speeds of ω1 = 300, 400 and 500 rpm. In the conventional multilayer coiled column with the upper mobile phase, the rotation speed combination type II yielded the best peak resolution while the rotation speed combination types III and IV had extremely low stationary phase retention even at higher revolution speeds. This inconvenience was eliminated by using the eccentric and the toroidal coiled column. The rotation speed combination type II for the eccentric coiled column and the type IV for the toroidal coiled column produced the best separation in both the upper and the lower mobile phases among four different rotation speed combination types. The overall results indicated that better peak resolution was obtained by the eccentric coiled column than by the toroidal coiled column except for the separation with the upper mobile phase at the low revolution speed.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Coil satellite centrifuge; Counter-current chromatography; Instrumentation; Partition efficiency; Separation of sugar derivatives

Mesh:

Substances:

Year:  2019        PMID: 30862407      PMCID: PMC6519705          DOI: 10.1016/j.chroma.2019.03.010

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  8 in total

1.  New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

Authors:  Kazufusa Shinomiya; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2006-01-06       Impact factor: 4.759

2.  Comparison of the peak resolution and the stationary phase retention between the satellite and the planetary motions using the coil satellite centrifuge with counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives.

Authors:  Kazufusa Shinomiya; Kazumasa Zaima; Yukina Harada; Miho Yasue; Naoki Harikai; Koji Tokura; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2016-12-21       Impact factor: 4.759

3.  Improved Separations of Proteins and Sugar Derivatives Using the Small-Scale Cross-Axis Coil Planet Centrifuge with Locular Multilayer Coiled Columns.

Authors:  Kazufusa Shinomiya; Motoki Umezawa; Manami Seki; Jun Nitta; Kazumasa Zaima; Naoki Harikai; Yoichiro Ito
Journal:  Separations       Date:  2016-09-22

4.  New small-scale cross-axis coil planet centrifuge. Partition efficiency and application to purification of bullfrog ribonuclease.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Koji Kobayashi; Hisashi Oshima; Susumu Kitanaka; Kazuhiro Yanagidaira; Haruo Sasaki; Minoru Muto; Michiharu Okano; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2007-03-16       Impact factor: 4.759

5.  Effect of elution modes on protein separation by cross-axis coil planet centrifuge with two different types of coiled columns.

Authors:  K Shinomiya; Y Kabasawa; Y Ito
Journal:  Prep Biochem Biotechnol       Date:  1999-05       Impact factor: 2.162

6.  Design of a coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with polar organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Koji Tokura; Emiru Kimura; Midori Takai; Naoki Harikai; Kazunori Yoshida; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2015-03-12       Impact factor: 4.759

7.  Countercurrent chromatographic separation of proteins using an eccentric coiled column with synchronous and nonsynchronous type-J planetary motions.

Authors:  Kazufusa Shinomiya; Kazunori Yoshida; Koji Tokura; Etsuhiro Tsukidate; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  Anal Sci       Date:  2015       Impact factor: 2.081

8.  Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

Authors:  Kazufusa Shinomiya; Kazuki Sato; Kazunori Yoshida; Koji Tokura; Hiroshi Maruyama; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2013-11-05       Impact factor: 4.759

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.