Literature DB >> 20046931

PARTITION EFFICIENCY OF NEWLY DESIGNED LOCULAR MULTILAYER COIL FOR COUNTERCURRENT CHROMATOGRAPHIC SEPARATION OF PROTEINS USING SMALL-SCALE CROSS-AXIS COIL PLANET CENTRIFUGE WITH AQUEOUS-AQUEOUS POLYMER PHASE SYSTEMS.

Kazufusa Shinomiya1, Yoichiro Ito.   

Abstract

Countercurrent chromatographic performance of the locular multilayer coil separation column newly designed in our laboratory was evaluated in terms of theoretical plate number, peak resolution and retention of the stationary phase in protein separation with an aqueous polymer phase system using the small-scale cross-axis coil planet centrifuge (X-axis CPC) fabricated in our laboratory. The locular column was made from 1.0 mm I.D., 2.0 mm O.D. or 1.5 mm I.D., 2.5 mm O.D. PTFE tubing compressed with a pair of hemostat at 2 or 4 cm intervals. The protein separation was performed using a set of stable proteins including cytochrome C, myoglobin and lysozyme with the 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate system under 1000 rpm of column revolution. The 1.5 mm I.D., 2.5 mm O.D. locular tubing compressed at 2 cm intervals yielded better partition efficiencies than the non-clamped tubing using both lower and upper mobile phases with satisfactory retention of the stationary phase. The overall results suggest that the newly designed locular multilayer coil is useful to the preparative separation of proteins with aqueous-aqueous polymer phase system using our small-scale X-axis CPC.

Entities:  

Year:  2009        PMID: 20046931      PMCID: PMC2757295          DOI: 10.1080/10826070902841547

Source DB:  PubMed          Journal:  J Liq Chromatogr Relat Technol        ISSN: 1082-6076            Impact factor:   1.312


  4 in total

1.  New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

Authors:  Kazufusa Shinomiya; Kazuhiro Yanagidaira; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2006-01-06       Impact factor: 4.759

2.  Studies on a new cross-axis coil planet centrifuge for performing counter-current chromatography. I. Design of the apparatus, retention of the stationary phase, and efficiency in the separation of proteins with polymer phase systems.

Authors:  K Shinomiya; J M Menet; H M Fales; Y Ito
Journal:  J Chromatogr       Date:  1993-08-06

3.  New small-scale cross-axis coil planet centrifuge. Partition efficiency and application to purification of bullfrog ribonuclease.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Koji Kobayashi; Hisashi Oshima; Susumu Kitanaka; Kazuhiro Yanagidaira; Haruo Sasaki; Minoru Muto; Michiharu Okano; Yoichiro Ito
Journal:  J Chromatogr A       Date:  2007-03-16       Impact factor: 4.759

4.  Effect of elution modes on protein separation by cross-axis coil planet centrifuge with two different types of coiled columns.

Authors:  K Shinomiya; Y Kabasawa; Y Ito
Journal:  Prep Biochem Biotechnol       Date:  1999-05       Impact factor: 2.162

  4 in total
  2 in total

1.  Improved Separations of Proteins and Sugar Derivatives Using the Small-Scale Cross-Axis Coil Planet Centrifuge with Locular Multilayer Coiled Columns.

Authors:  Kazufusa Shinomiya; Motoki Umezawa; Manami Seki; Jun Nitta; Kazumasa Zaima; Naoki Harikai; Yoichiro Ito
Journal:  Separations       Date:  2016-09-22

2.  Partition Efficiency of High-Pitch Locular Multilayer Coil for Countercurrent Chromatographic Separation of Proteins Using Small-Scale Cross-Axis Coil Planet Centrifuge and Application to Purification of Various Collagenases with Aqueous-Aqueous Polymer Phase Systems.

Authors:  Kazufusa Shinomiya; Hiroko Kobayashi; Norio Inokuchi; Kazuya Nakagomi; Yoichiro Ito
Journal:  J Liq Chromatogr Relat Technol       Date:  2011-01       Impact factor: 1.312

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.