Literature DB >> 16394337

Motion correction for improved target localization with on-board cone-beam computed tomography.

T Li1, E Schreibmann, Y Yang, L Xing.   

Abstract

On-board imager (OBI) based cone-beam computed tomography (CBCT) has become available in radiotherapy clinics to accurately identify the target in the treatment position. However, due to the relatively slow gantry rotation (typically about 60 s for a full 360 degrees scan) in acquiring the CBCT projection data, the patient's respiratory motion causes serious problems such as blurring, doubling, streaking and distortion in the reconstructed images, which heavily degrade the image quality and the target localization. In this work, we present a motion compensation method for slow-rotating CBCT scans by incorporating into image reconstruction a patient-specific motion model, which is derived from previously obtained four-dimensional (4D) treatment planning CT images of the same patient via deformable registration. The registration of the 4D CT phases results in transformations representing a temporal sequence of three-dimensional (3D) deformation fields, or in other words, a 4D model of organ motion. The algorithm was developed heuristically in two-dimensional (2D) parallel-beam geometry and extended to 3D cone-beam geometry. By simulations with digital phantoms capable of translational motion and other complex motion, we demonstrated that the algorithm can reduce the motion artefacts locally, and restore the tumour size and shape, which may thereby improve the accuracy of target localization and patient positioning when CBCT is used as the treatment guidance.

Entities:  

Mesh:

Year:  2005        PMID: 16394337     DOI: 10.1088/0031-9155/51/2/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  37 in total

1.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

3.  Intrafractional motion of the prostate during hypofractionated radiotherapy.

Authors:  Yaoqin Xie; David Djajaputra; Christopher R King; Sabbir Hossain; Lijun Ma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

4.  Iterative sorting for four-dimensional CT images based on internal anatomy motion.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter; Peter A Balter
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

5.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

6.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

7.  Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT.

Authors:  Frank Bergner; Timo Berkus; Markus Oelhafen; Patrik Kunz; Tinsu Pan; Marc Kachelriess
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

8.  Prior Image Constrained Compressed Sensing (PICCS).

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-03-03

9.  Respiratory triggered 4D cone-beam computed tomography: a novel method to reduce imaging dose.

Authors:  Benjamin J Cooper; Ricky T O'Brien; Salim Balik; Geoffrey D Hugo; Paul J Keall
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  CT to cone-beam CT deformable registration with simultaneous intensity correction.

Authors:  Xin Zhen; Xuejun Gu; Hao Yan; Linghong Zhou; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.