Literature DB >> 16392228

First human case of retrograde transcatheter implantation of an aortic valve prosthesis.

David Paniagua1, José A Condado, José Besso, Manuel Vélez, Bruno Burger, Salvatore Bibbo, Douglas Cedeno, Harry Acquatella, Carlos Mejia, Eduardo Induni, R David Fish.   

Abstract

The transcatheter route is an emerging approach to treating valvular disease in high-risk patients. The 1st clinical antegrade transcatheter placement of an aortic valve prosthesis was reported in 2002. We describe the first retrograde transcatheter implantation of a new aortic valve prosthesis, in a 62-year-old man with inoperable calcific aortic stenosis and multiple severe comorbidities. Via the right femoral artery, a Cook introducer was advanced into the abdominal aorta. The aortic valve was crossed with a straight wire, and a pigtail catheter was advanced into the left ventricle to obtain pressure-gradient and anatomic measurements. An 18-mm valvuloplasty balloon was then used to predilate the aortic valve. Initial attempts to position the prosthetic valve caused a transient cardiac arrest. Implantation was achieved by superimposing the right coronary angiogram onto fluoroscopic landmarks in the same radiographic plane. A balloon-expandable frame was used to deliver the valve. After device implantation, the transvalvular gradient was <5 mmHg. The cardiac output increased from 1 to 5 L/min, and urine production increased to 200 mL/h. The patient was extubated on the 2nd postimplant day. Twelve hours later, he had to be reintubated because of respiratory distress and high pulmonary pressures. His condition deteriorated, and he died of biventricular failure and refractory hypotension on day 5. Despite the severe hypotension, valve function was satisfactory on echo-Doppler evaluation. In our patient, retrograde transcatheter implantation of a prosthetic aortic valve yielded excellent hemodynamic results and paved the way for further use of this technique in selected high-risk patients.

Entities:  

Mesh:

Year:  2005        PMID: 16392228      PMCID: PMC1336718     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  15 in total

1.  Steps toward percutaneous aortic valve replacement.

Authors:  Younes Boudjemline; Philipp Bonhoeffer
Journal:  Circulation       Date:  2002-02-12       Impact factor: 29.690

2.  Images in cardiovascular medicine. Percutaneous heart valve in the chronic in vitro testing model.

Authors:  David Paniagua; Eduardo Induni; Carolyne Ortiz; Carlos Mejia; Francisco Lopez-Jimenez; R David Fish
Journal:  Circulation       Date:  2002-09-17       Impact factor: 29.690

3.  Development and initial experimental evaluation of a prosthetic aortic valve for transcatheter placement. Work in progress.

Authors:  D Pavcnik; K C Wright; S Wallace
Journal:  Radiology       Date:  1992-04       Impact factor: 11.105

4.  Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs.

Authors:  H R Andersen; L L Knudsen; J M Hasenkam
Journal:  Eur Heart J       Date:  1992-05       Impact factor: 29.983

5.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I.

Authors:  R GORLIN; S G GORLIN
Journal:  Am Heart J       Date:  1951-01       Impact factor: 4.749

6.  Catheter-mounted aortic valves.

Authors:  S D Moulopoulos; L Anthopoulos; S Stamatelopoulos; M Stefadouros
Journal:  Ann Thorac Surg       Date:  1971-05       Impact factor: 4.330

7.  Catheter-implanted prosthetic heart valves. Transluminal catheter implantation of a new expandable artificial heart valve in the descending thoracic aorta in isolated vessels and closed chest pigs.

Authors:  L L Knudsen; H R Andersen; J M Hasenkam
Journal:  Int J Artif Organs       Date:  1993-05       Impact factor: 1.595

8.  Percutaneous aortic valve replacement: an experimental study. I. Studies on implantation.

Authors:  Georg Lutter; Daniela Kuklinski; Georg Berg; Patrick Von Samson; Juergen Martin; Michael Handke; Peter Uhrmeister; Friedhelm Beyersdorf
Journal:  J Thorac Cardiovasc Surg       Date:  2002-04       Impact factor: 5.209

9.  Percutaneous insertion of the pulmonary valve.

Authors:  Philipp Bonhoeffer; Younes Boudjemline; Shakeel A Qureshi; Jerome Le Bidois; Laurence Iserin; Philippe Acar; Jacques Merckx; Jean Kachaner; Daniel Sidi
Journal:  J Am Coll Cardiol       Date:  2002-05-15       Impact factor: 24.094

10.  Balloon catheter with check valves for experimental relief of acute aortic regurgitation.

Authors:  T Matsubara; M Yamazoe; Y Tamura; M Ohshima; Y Yamazaki; M Suzuki; T Izumi; A Shibata
Journal:  Am Heart J       Date:  1992-10       Impact factor: 4.749

View more
  5 in total

1.  Temporary support with Tandemheart pVAD during percutaneous aortic valve replacement in an animal model: rationale and methodology.

Authors:  Biswajit Kar; Reynolds M Delgado; Andrew B Civitello; Pranav Loyalka; David Paniagua; R David Fish; Matthew D Forrester; Daniel Moser; Branislav Radovancevic
Journal:  Tex Heart Inst J       Date:  2005

2.  Transcatheter aortic valve implantation (TAVI): the hype and the hope.

Authors:  José G Díez
Journal:  Tex Heart Inst J       Date:  2013

3.  Transcatheter aortic valve implantation: Current status and future perspectives.

Authors:  Pablo Salinas; Raul Moreno; Jose L Lopez-Sendon
Journal:  World J Cardiol       Date:  2011-06-26

Review 4.  TAVI 2012: state of the art.

Authors:  Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender
Journal:  J Thromb Thrombolysis       Date:  2013-05       Impact factor: 2.300

5.  Hydrodynamic Isotonic Fluid Delivery Ameliorates Moderate-to-Severe Ischemia-Reperfusion Injury in Rat Kidneys.

Authors:  Jason A Collett; Peter R Corridon; Purvi Mehrotra; Alexander L Kolb; George J Rhodes; Caroline A Miller; Bruce A Molitoris; Janice G Pennington; Ruben M Sandoval; Simon J Atkinson; Silvia B Campos-Bilderback; David P Basile; Robert L Bacallao
Journal:  J Am Soc Nephrol       Date:  2017-01-25       Impact factor: 10.121

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.