The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling.

Biswajit Kar1, Reynolds M Delgado, O H Frazier, Igor D Gregoric, Matthew T Harting, Yasmin Wadia, Timothy J Myers, Robert D Moser, Jonathan Freund.   

Abstract

Axial-flow ventricular assist devices (VADs) can be implanted either through a left thoracotomy with outflow-graft anastomosis to the descending thoracic aorta or through a midline sternotomy with anastomosis to the ascending aorta. Each method has advantages and disadvantages. Because these VADs produce nonpulsatile flow, their hemodynamic characteristics differ from those of pulsatile devices. These differences may have important clinical consequences, particularly in relation to the outflow-graft configuration. We describe a computer-generated flow model that we created to illustrate the flow dynamics and possible clinical consequences of each method. The simulations indicate that the location of the anastomosis has important qualitative effects on flow in the ascending aorta and aortic arch. At high VAD outputs (> or =75%), native cardiac output cannot supply the carotid and subclavian arteries. With a descending aortic anastomosis, net backward flow occurs in the descending aorta to supply these branches. Consequently, the aortic arch has a region with almost no net flow, where fluid particles stagnate over many cardiac cycles, possibly causing thrombogenesis. With an ascending aortic anastomosis, the arch has no stagnant region, although flow turbulence still occurs. When the aortic valve remains closed, so that the total output occurs through the VAD, the aortic root has a region of nearly stagnant flow. With an ascending aortic anastomosis, a small degree of recirculatory flow may prevent complete stagnation at the aortic root. With the descending aortic anastomosis, however, no recirculation occurs. These results help delineate the complex flow dynamics and the advantages and drawbacks of each technique.

Entities:  

Mesh:

Year:  2005        PMID: 16392208      PMCID: PMC1336698     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions.

Authors:  M S Olufsen; C S Peskin; W Y Kim; E M Pedersen; A Nadim; J Larsen
Journal:  Ann Biomed Eng       Date:  2000 Nov-Dec       Impact factor: 3.934

Review 2.  Left ventricular assist device implantation: short and long-term surgical complications.

Authors:  W Piccione
Journal:  J Heart Lung Transplant       Date:  2000-08       Impact factor: 10.247

Review 3.  Pulse wave analysis in the assessment of patients with left ventricular assist device.

Authors:  C Vlachopoulos; P Mcdonald; P Spratt; M O'Rourke
Journal:  J Heart Lung Transplant       Date:  2001-01       Impact factor: 10.247

Review 4.  Clinical choices for circulatory assist devices.

Authors:  R A Ott; T C Mills; J Eugene; A B Gazzaniga
Journal:  ASAIO Trans       Date:  1990 Oct-Dec

5.  Structured tree outflow condition for blood flow in larger systemic arteries.

Authors:  M S Olufsen
Journal:  Am J Physiol       Date:  1999-01

6.  Performance optimization of left ventricular assistance. A computer model study.

Authors:  K L Platt; T W Moore; O Barnea; S E Dubin; D Jaron
Journal:  ASAIO J       Date:  1993 Jan-Mar       Impact factor: 2.872

7.  Left ventricular outflow tract obstruction associated with chronic ventricular assist device support.

Authors:  Sam Baradarian; Walter P Dembitsky; Brian Jaski; Amir Abolhoda; Robert Adamson; Suzanne Chillcot; Pat O Daily
Journal:  ASAIO J       Date:  2002 Nov-Dec       Impact factor: 2.872

Review 8.  [Heart assist systems--current status].

Authors:  Roland Hetzer; Michael J Jurmann; Evgenij V Potapov; Ewald Hennig; Brigitte Stiller; Johannes H Müller; Yuguo Weng
Journal:  Herz       Date:  2002-08       Impact factor: 1.443

  8 in total
  11 in total

1.  Anastomosis of the outflow cannula to the descending aorta in a HeartWare left ventricular assist device.

Authors:  Ryan J Koene; Kenneth K Liao; Peter M Eckman; Ranjit John
Journal:  J Cardiol Cases       Date:  2014-11-15

2.  Impact of LVAD Implantation Site on Ventricular Blood Stagnation.

Authors:  Anthony R Prisco; Alberto Aliseda; Jennifer A Beckman; Nahush A Mokadam; Claudius Mahr; Guilherme J M Garcia
Journal:  ASAIO J       Date:  2017 Jul/Aug       Impact factor: 2.872

Review 3.  Review of recent results using computational fluid dynamics simulations in patients receiving mechanical assist devices for end-stage heart failure.

Authors:  Mina Berty Farag; Christof Karmonik; Fabian Rengier; Matthias Loebe; Matthias Karck; Hendrik von Tengg-Kobligk; Arjang Ruhparwar; Sasan Partovi
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

4.  Apicoaortic conduit and cerebral perfusion in mixed aortic valve disease: a computational analysis.

Authors:  Gionata Fragomeni; Michele Rossi; Francesca Condemi; Rosario Mazzitelli; Giuseppe Filiberto Serraino; Attilio Renzulli
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-08-20

5.  Screening for Outflow Cannula Malfunction of Left Ventricular Assist Devices (LVADs) With the Use of Doppler Echocardiography: New LVAD-Specific Reference Values for Contemporary Devices.

Authors:  Jonathan Grinstein; Eric Kruse; Keith Collins; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Nir Uriel; Roberto M Lang
Journal:  J Card Fail       Date:  2016-06-08       Impact factor: 5.712

6.  Commentary: Less-invasive approaches to big complex problems in patients with end-stage heart disease.

Authors:  Stephanie N Nguyen; Tom C Nguyen
Journal:  JTCVS Tech       Date:  2020-09-16

7.  Theoretical estimation of cannulation methods for left ventricular assist device support as a bridge to recovery.

Authors:  Ki Moo Lim; Jeong Sang Lee; Jin-Ho Song; Chan-Hyun Youn; Jae-Sung Choi; Eun Bo Shim
Journal:  J Korean Med Sci       Date:  2011-11-29       Impact factor: 2.153

Review 8.  Minimally-invasive LVAD Implantation: State of the Art.

Authors:  Jasmin S Hanke; Sebastian V Rojas; Murat Avsar; Axel Haverich; Jan D Schmitto
Journal:  Curr Cardiol Rev       Date:  2015

Review 9.  Complications of Continuous-Flow Mechanical Circulatory Support Devices.

Authors:  Harsh Patel; Raef Madanieh; Constantine E Kosmas; Satya K Vatti; Timothy J Vittorio
Journal:  Clin Med Insights Cardiol       Date:  2015-05-21

10.  Concomitant Respiratory Failure Can Impair Myocardial Oxygenation in Patients with Acute Cardiogenic Shock Supported by VA-ECMO.

Authors:  Anthony R Prisco; Jazmin Aguado-Sierra; Constantine Butakoff; Mariano Vazquez; Guillaume Houzeaux; Beatriz Eguzkitza; Jason A Bartos; Demetris Yannopoulos; Ganesh Raveendran; Mikayle Holm; Tinen Iles; Claudius Mahr; Paul A Iaizzo
Journal:  J Cardiovasc Transl Res       Date:  2021-02-23       Impact factor: 3.216

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.