Left ventricular outflow tract obstruction associated with chronic ventricular assist device support.

Sam Baradarian1, Walter P Dembitsky, Brian Jaski, Amir Abolhoda, Robert Adamson, Suzanne Chillcot, Pat O Daily.   

Abstract

Favorable long-term patient outcome after insertion of a left ventricular assist device (LVAD) as a bridge to recovery or destination therapy for the treatment of end-stage cardiomyopathy is adversely affected by pathophysiologic changes affecting the heart. Alterations in the native aortic valve apparatus, specifically aortic valve cusp fusion, is an example of such a phenomenon and may especially affect patients in cases of bridge to recovery, a rare but reported event. A retrospective review of the last 33 LVAD placements at our institution was conducted, including reviews of operative reports and pathologic examinations of the native hearts. Seven hearts were found to have varying degrees of aortic valve cusp fusion after chronic LVAD support (63-1, 339 days). Five of these patients had native aortic valves, and two had bioprosthetic valves. The left ventricular outflow tracts in two patients were surgically occluded at the time of LVAD insertion. Aortic valve cusp fusion occurs in roughly 25% of patients on chronic LVAD support. This phenomenon may prove to be clinically significant by creating a potential source of emboli and infection. In addition, in the case of myocardial recovery, left ventricular outflow tract obstruction could limit parallel flow and produce suprasystemic ventricular pressures that in turn would elevate left ventricular end diastolic pressures. The latter may contribute to further myocardial injury, ultimately limiting the ability of an otherwise recovered heart to be weaned from LVAD support.

Entities:  

Mesh:

Year:  2002        PMID: 12455780     DOI: 10.1097/00002480-200211000-00016

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: Implantation technique and computer flow modeling.

Authors:  Biswajit Kar; Reynolds M Delgado; O H Frazier; Igor D Gregoric; Matthew T Harting; Yasmin Wadia; Timothy J Myers; Robert D Moser; Jonathan Freund
Journal:  Tex Heart Inst J       Date:  2005

2.  Bioprosthetic aortic valve changes late after insertion of a left ventricular assist device.

Authors:  Katherine Khvilivitzky; Gonzalo V Gonzalez-Stawinski
Journal:  Proc (Bayl Univ Med Cent)       Date:  2013-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.