Literature DB >> 16374877

A polymer-based MR-compatible guidewire: a study to explore new prospects for interventional peripheral magnetic resonance angiography (ipMRA).

Ralf Mekle1, Eugen Hofmann, Klaus Scheffler, Deniz Bilecen.   

Abstract

PURPOSE: To introduce a newly developed polymer-based and magnetic resonance (MR)-compatible guidewire and to explore its capabilities with respect to interventional peripheral magnetic resonance angiography (ipMRA) in a flow phantom.
MATERIALS AND METHODS: The guidewire is based on a polyetheretherketone (PEEK) polymer core, and small iron particles are embedded in its coating. A passive device tracking technique was designed utilizing a susceptibility artifact induced by the wire in images acquired with a balanced steady-state free precession (b-SSFP) sequence using small flip angles. The position of the guidewire tip was determined from image intensity maxima and overlayed onto a roadmap in near real-time. Guidewire tracking and balloon angioplasty of an artificial stenosis were attempted in two configurations of a flow phantom.
RESULTS: Successful passive guidewire tracking was performed for all phantom configurations. Robustness and accuracy of the tracking technique were sufficient for phantom studies. A balloon catheter was placed into the stenosis using the guidewire under complete MR guidance, and subsequent balloon angioplasty yielded improved flow conditions.
CONCLUSION: The new guidewire is well-suited for clinical application due to an absence of the risk of core fracture and its atraumatic flexible tip. It opens novel prospects for the realization of ipMRA in humans that need to be explored in further studies. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16374877     DOI: 10.1002/jmri.20486

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  17 in total

1.  Echo-dephased steady state free precession.

Authors:  Sunil Patil; Oliver Bieri; Klaus Scheffler
Journal:  MAGMA       Date:  2009-05-16       Impact factor: 2.310

Review 2.  MR-guided endovascular interventions: a comprehensive review on techniques and applications.

Authors:  Sebastian Kos; Rolf Huegli; Georg M Bongartz; Augustinus L Jacob; Deniz Bilecen
Journal:  Eur Radiol       Date:  2007-12-11       Impact factor: 5.315

3.  A technique for MRI-guided transrectal deep pelvic abscess drainage.

Authors:  Sherif Gamal Nour; Jamal J Derakhshan; Nila J Akhtar; Martin A Ayres; Mark E Clampitt; Thomas A Stellato; Jeffrey L Duerk
Journal:  AJR Am J Roentgenol       Date:  2008-10       Impact factor: 3.959

4.  Radial MRI with variable echo times: reducing the orientation dependency of susceptibility artifacts of an MR-safe guidewire.

Authors:  Katharina E Schleicher; Michael Bock; Klaus Düring; Stefan Kroboth; Axel J Krafft
Journal:  MAGMA       Date:  2017-08-02       Impact factor: 2.310

5.  Susceptibility artifacts from metallic markers and cardiac catheterization devices on a high-performance 0.55 T MRI system.

Authors:  Burcu Basar; Merdim Sonmez; Dursun Korel Yildirim; Ram Paul; Daniel A Herzka; Ozgur Kocaturk; Robert J Lederman; Adrienne E Campbell-Washburn
Journal:  Magn Reson Imaging       Date:  2020-12-09       Impact factor: 2.546

Review 6.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

Review 7.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11

Review 8.  An overview on the advances in cardiovascular interventional MR imaging.

Authors:  Olaf Saborowski; Maythem Saeed
Journal:  MAGMA       Date:  2007-05-09       Impact factor: 2.310

9.  Positive contrast with alternating repetition time SSFP (PARTS): a fast imaging technique for SPIO-labeled cells.

Authors:  Tolga Cukur; Mayumi Yamada; William R Overall; Phillip Yang; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

Review 10.  Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy.

Authors:  Fabio Settecase; Alastair J Martin; Prasheel Lillaney; Aaron Losey; Steven W Hetts
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.