OBJECTIVES: To establish radiation risks for patients undergoing fluoroscopically guided cardiac resynchronization device implantation. BACKGROUND: Cardiac resynchonization therapy (CRT) may be associated with extended fluoroscopic exposure. METHODS: The fluoroscopy time, dose-area product (DAP), exposure parameters, and percentage contribution of the fluoroscopic projections commonly used were recorded in a series of 14 consecutive patients referred for cardiac resynchronization device implantation and compared to corresponding data obtained from a control group of 20 patients who underwent a conventional rhythm device implantation operation. The DAP to peak skin dose, DAP to effective dose, and DAP to gonadal dose conversion factors were determined for biventricular pacing and conventional rhythm device implantation using a humanoid phantom and thermoluminescence dosimetry. RESULTS: The mean total fluoroscopy time and DAP values were 35.2 min and 4,765 cGy cm2, respectively, for biventricular pacing and 8.2 min and 1,106 cGy cm2, respectively, for conventional rhythm device implantation. Patient skin dose from biventricular pacing procedures requiring extended fluoroscopic exposure may exceed threshold dose for the induction of skin effects only if X-ray source-to-skin distance is kept low. The risk values for fatal cancer and severe hereditary disorders, respectively, associated with a typical CRT procedure were 273 per million and 0.2 per million treated patients. CONCLUSIONS: Radiation risks associated with fluoroscopically guided CRT procedures may be considerable. Present data may be used for the estimation of patient radiation risks from CRT procedures performed in other institutions.
OBJECTIVES: To establish radiation risks for patients undergoing fluoroscopically guided cardiac resynchronization device implantation. BACKGROUND: Cardiac resynchonization therapy (CRT) may be associated with extended fluoroscopic exposure. METHODS: The fluoroscopy time, dose-area product (DAP), exposure parameters, and percentage contribution of the fluoroscopic projections commonly used were recorded in a series of 14 consecutive patients referred for cardiac resynchronization device implantation and compared to corresponding data obtained from a control group of 20 patients who underwent a conventional rhythm device implantation operation. The DAP to peak skin dose, DAP to effective dose, and DAP to gonadal dose conversion factors were determined for biventricular pacing and conventional rhythm device implantation using a humanoid phantom and thermoluminescence dosimetry. RESULTS: The mean total fluoroscopy time and DAP values were 35.2 min and 4,765 cGy cm2, respectively, for biventricular pacing and 8.2 min and 1,106 cGy cm2, respectively, for conventional rhythm device implantation. Patient skin dose from biventricular pacing procedures requiring extended fluoroscopic exposure may exceed threshold dose for the induction of skin effects only if X-ray source-to-skin distance is kept low. The risk values for fatal cancer and severe hereditary disorders, respectively, associated with a typical CRT procedure were 273 per million and 0.2 per million treated patients. CONCLUSIONS: Radiation risks associated with fluoroscopically guided CRT procedures may be considerable. Present data may be used for the estimation of patient radiation risks from CRT procedures performed in other institutions.
Authors: Douglas N Stephens; Uyen T Truong; Amin Nikoozadeh; Omer Oralkan; Chi Hyung Seo; Jonathan Cannata; Aaron Dentinger; Kai Thomenius; Alan de la Rama; Tho Nguyen; Feng Lin; Pierre Khuri-Yakub; Aman Mahajan; Kalyanam Shivkumar; Matt O'Donnell; David J Sahn Journal: J Ultrasound Med Date: 2012-02 Impact factor: 2.153
Authors: Jersey Chen; Andrew J Einstein; Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Henry H Ting; Nilay D Shah; Khurram Nasir; Brahmajee K Nallamothu Journal: J Am Coll Cardiol Date: 2010-07-09 Impact factor: 24.094
Authors: Loren P Budge; Adam S Helms; Michael Salerno; Christopher M Kramer; Frederick H Epstein; Kenneth C Bilchick Journal: JACC Cardiovasc Imaging Date: 2012-08
Authors: Gorav Ailawadi; Damien J Lapar; Brian R Swenson; Cory D Maxwell; Micah E Girotti; James D Bergin; John A Kern; John P Dimarco; Srijoy Mahapatra Journal: Heart Rhythm Date: 2010-01-20 Impact factor: 6.343
Authors: Mark J Eisenberg; Jonathan Afilalo; Patrick R Lawler; Michal Abrahamowicz; Hugues Richard; Louise Pilote Journal: CMAJ Date: 2011-02-07 Impact factor: 8.262
Authors: D N Stephens; J Cannata; Ruibin Liu; Jian Zhong Zhao; K K Shung; Hien Nguyen; R Chia; A Dentinger; D Wildes; K E Thomenius; A Mahajan; K Shivkumar; Kang Kim; M O'Donnell; A Nikoozadeh; O Oralkan; P T Khuri-Yakub; D J Sahn Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2008-07 Impact factor: 2.725
Authors: Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu Journal: N Engl J Med Date: 2009-08-27 Impact factor: 91.245