| Literature DB >> 16351719 |
Jan Lucas Hoving1, Jan J M Pool, Henk van Mameren, Walter J L M Devillé, Willem J J Assendelft, Henrica C W de Vet, Andrea F de Winter, Bart W Koes, Lex M Bouter.
Abstract
BACKGROUND: Reproducibility measurements of the range of motion are an important prerequisite for the interpretation of study results. The aim of the study is to assess the intra-rater and inter-rater reproducibility of the measurement of active Range of Motion (ROM) in patients with neck pain using the Cybex Electronic Digital Inclinometer-320 (EDI-320).Entities:
Mesh:
Year: 2005 PMID: 16351719 PMCID: PMC1343553 DOI: 10.1186/1471-2474-6-59
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Figure 1Picture of head position during rotation.
Figure 2Flow diagram measurements and assessment of intra- and inter-rater reproducibility.
Characteristics of patients.
| Characteristics | Frequency* (n = 32) |
| Age (mean, sd) | 45.5 (9.2) |
| Female | 20 (62.5) |
| Headache | 2 (6.3) |
| Trauma reported as cause | 8 (25.0) |
| Reported stiffness of the neck | 9 (28.1) |
| Previous neck pain episodes | 18 (56.3) |
| Current pain 0–10 (mean, sd) † | 4.2 (2.3) |
| NDI score (mean, sd) ‡ | 15.2 (8.3) |
| Duration neck pain (median; IQR$ | 13.5 (8.0, 25.5) |
* Number of patients and % between brackets unless stated otherwise
† Current pain was measured on a numerical 11-point scale ranging from 0 = no pain to 10 = worst pain.
‡ Neck Disability Index: disability and pain measured by 10 items ranging from 0–5 points. Maximal disability 50 points
$ IQR = Inter-Quartile Range
Intrarater reproducibility analyses
| Tested movements | LoA | ICC | 95% CI | ||||||
| mean | SD | mean | SD | mean | SD | ||||
| Rater A | |||||||||
| Flexion-extension | 101.3 | 21.6 | 103.8 | 23.0 | -2.5 | 5.7 | -2.5 ± 11.1 | 0.96 | 0.93, 0.98 |
| Lateral-flexion | 72.6 | 13.8 | 72.7 | 14.4 | -0.1 | 5.3 | -0.1 ± 10.4 | 0.93 | 0.86, 0.97 |
| Rotation | 135.4 | 30.4 | 141.3 | 29.7 | -5.9 | 6.9 | -5.9 ± 13.5 | 0.96 | 0.91, 0.98 |
| Rater B | |||||||||
| Flexion-extension | 99.8 | 21.0 | 98.8 | 22.7 | 1.0 | 5.6 | 1.0 ± 11.1 | 0.97 | 0.93, 0.98 |
| Lateral-flexion | 71.8 | 12.3 | 72.4 | 14.1 | -0.6 | 5.0 | -0.6 ± 9.8 | 0.93 | 0.86, 0.96 |
| Rotation | 138.3 | 27.0 | 141.0 | 28.9 | -2.7 | 7.4 | -2.7 ± 14.4 | 0.96 | 0.92, 0.98 |
* LoA = 95% Limits of Agreement, ICC = Intra-class Correlation Coefficient, 95% CI = 95% Confidence Interval
Figure 3Plotted differences within rater A against the mean value of the first and second measurement for each patient for cervical flexion-extension, lateral flexion and rotation*. * Presented is the line of the mean difference (in the middle) and the limits of agreement (the two dotted outer lines corresponding with the +2 SD's or – 2 SD's of the mean difference between the 1st and 2nd rating by rater A)
Interrater reproducibility analyses *
| Tested movements | LoA | ICC | 95% CI | ||||||
| mean | SD | mean | SD | mean | SD | ||||
| Mean of two ratings | |||||||||
| Flexion-extension | 102.6 | 22.2 | 99.3 | 21.7 | 3.3 | 8.7 | 3.3 ± 17.0 | 0.95 | 0.90, 0.98 |
| Lateral-flexion | 72.6 | 13.9 | 72.1 | 13.0 | 0.5 | 8.7 | 0.5 ± 17.0 | 0.89 | 0.77, 0.94 |
| Rotation | 138.4 | 29.9 | 139.7 | 27.7 | -1.3 | 12.5 | -1.3 ± 24.6 | 0.95 | 0.90, 0.98 |
| One rating | |||||||||
| Flexion-extension | 101.3 | 21.6 | 99.8 | 21.0 | 1.6 | 10.1 | 1.6 ± 19.8 | 0.89 | 0.78, 0.94 |
| Lateral-flexion | 72.6 | 13.8 | 71.8 | 12.3 | 0.8 | 8.9 | 0.8 ± 17.5 | 0.77 | 0.58, 0.88 |
| Rotation | 135.4 | 30.4 | 138.3 | 27.0 | -2.9 | 13.7 | -2.9 ± 26.0 | 0.88 | 0.78, 0.94 |
| Low pain intensity | |||||||||
| Flexion-extension | 111.0 | 17.5 | 106.8 | 16.1 | 4.3 | 8.2 | 4.3 ± 16.1 | 0.92 | 0.79, 0.97 |
| Lateral-flexion | 77.0 | 11.3 | 76.0 | 11.6 | 1.1 | 8.9 | 1.1 ± 17.2 | 0.82 | 0.59, 0.93 |
| Rotation | 147.7 | 20.7 | 148.0 | 17.4 | -0.3 | 12.8 | -0.3 ± 25.1 | 0.88 | 0.71, 0.95 |
| High pain intensity | |||||||||
| Flexion-extension | 81.0 | 18.1 | 80.2 | 23.1 | 0.8 | 9.8 | 0.8 ± 19.2 | 0.95 | 0.76, 0.99 |
| Lateral-flexion | 61.4 | 14.1 | 62.3 | 11.5 | -0.8 | 8.4 | -0.8 ± 16.4 | 0.89 | 0.50, 0.98 |
| Rotation | 114.6 | 37.3 | 118.4 | 37.8 | -3.8 | 12.1 | -3.8 ± 23.8 | 0.97 | 0.89, 0.99 |
* LoA = 95% Limits of Agreement, ICC = Intra-class Correlation Coefficient, 95% CI = 95 % Confidence Interval