Literature DB >> 8420517

Interrater reliability of the Cybex EDI-320 and fluid goniometer in normals and patients with low back pain.

C M Chiarello1, R Savidge.   

Abstract

We compared the interrater reliability of the Cybex Electronic Digital Inclinometer-320a (EDI) and the fluid goniometer for measuring lumbar spine range of motion (ROM) in flexion, extension, and prone extension in adults not experiencing back pain and low-back pain patients. We also investigated whether prior palpation training improves reliability of lumbar ROM measurements using these tools. A repeated measures factorial design was used with a 6 x 6 Latin square to balance the order of testing. Twelve adults not experiencing back pain and six subacute low-back-pain patients were measured by two trained and one untrained therapist in all positions with both tools. The L1 and S2 spinous processes were palpated and marked for each measurement. Results of several three-way ANOVAs indicate that no significant differences exist between the tools for nonpatients or patients regardless of position. Using the Intraclass Correlation Coefficient both tools exhibited acceptable reliability under most conditions. The fluid goniometer exhibited better reliability for patients than nonpatients, although this pattern was not present with the EDI. With the exception of extension, prior palpation training did not improve measurement with either tool.

Entities:  

Mesh:

Year:  1993        PMID: 8420517

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  8 in total

Review 1.  Aggressive exercise as treatment for chronic low back pain.

Authors:  Isaac Cohen; James Rainville
Journal:  Sports Med       Date:  2002       Impact factor: 11.136

2.  Current standards for measuring spinal range of motion for impairment.

Authors:  Leanne N Cupon; Warren T Jahn
Journal:  J Chiropr Med       Date:  2003

3.  A prospective study of the interrelationship between subjective and objective measures of disability before and 2 months after lumbar decompression surgery for disc herniation.

Authors:  Anne F Mannion; Jiri Dvorak; Markus Müntener; Dieter Grob
Journal:  Eur Spine J       Date:  2005-04-14       Impact factor: 3.134

4.  Normal motion of the lumbar spine as related to age and gender.

Authors:  J Dvorák; E G Vajda; D Grob; M M Panjabi
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

5.  Effectiveness of behavioral graded activity after first-time lumbar disc surgery: short term results of a randomized controlled trial.

Authors:  R W J G Ostelo; H C W de Vet; M W Berfelo; M R Kerckhoffs; J W S Vlaeyen; P M J C Wolters; P A van den Brandt
Journal:  Eur Spine J       Date:  2003-09-23       Impact factor: 3.134

6.  Reproducibility of cervical range of motion in patients with neck pain.

Authors:  Jan Lucas Hoving; Jan J M Pool; Henk van Mameren; Walter J L M Devillé; Willem J J Assendelft; Henrica C W de Vet; Andrea F de Winter; Bart W Koes; Lex M Bouter
Journal:  BMC Musculoskelet Disord       Date:  2005-12-13       Impact factor: 2.362

7.  Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer.

Authors:  Andrea F de Winter; Monique A M B Heemskerk; Caroline B Terwee; Marielle P Jans; Walter Devillé; Dirk-Jan van Schaardenburg; Rob J P M Scholten; Lex M Bouter
Journal:  BMC Musculoskelet Disord       Date:  2004-06-14       Impact factor: 2.362

8.  Review of methods used by chiropractors to determine the site for applying manipulation.

Authors:  John J Triano; Brian Budgell; Angela Bagnulo; Benjamin Roffey; Thomas Bergmann; Robert Cooperstein; Brian Gleberzon; Christopher Good; Jacquelyn Perron; Rodger Tepe
Journal:  Chiropr Man Therap       Date:  2013-10-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.