Literature DB >> 16344129

Investigation of intensity thresholds for ultrasound tissue erosion.

Zhen Xu1, J Brian Fowlkes, Achi Ludomirsky, Charles A Cain.   

Abstract

Our previous studies have shown that short intense pulses delivered at certain pulse repetition frequencies (PRF) can achieve localized, clean erosion in soft tissue. In this paper, the intensity thresholds for ultrasound induced erosion and the effects of pulse intensity on erosion characterized by axial erosion rate, perforation area and volume erosion rate were investigated on in vitro porcine atrial wall tissue. Ultrasound pulses with a 3-cycle pulse duration and a 20-kHz PRF were delivered by a 788-kHz single element focused transducer. I(SPPA) values of 1000 to 9000 W/cm2 were tested. Results show the following: (1) the estimated intensity threshold for generating erosion was at I(SPPA) of 3220 W/cm2; (2) the axial erosion rate increased with higher intensity at I(SPPA) < or = 5000 W/cm2, while decreased with higher intensity at I(SPPA) > or = 5000 W/cm2; and (3) the perforation area and the volume erosion rate increased with higher intensity.

Mesh:

Year:  2005        PMID: 16344129      PMCID: PMC2676879          DOI: 10.1016/j.ultrasmedbio.2005.07.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  28 in total

1.  Microbubble-enhanced cavitation for noninvasive ultrasound surgery.

Authors:  Binh C Tran; Jongbum Seo; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-10       Impact factor: 2.725

2.  A novel method for the measurement of acoustic speed.

Authors:  I Y Kuo; B Hete; K K Shung
Journal:  J Acoust Soc Am       Date:  1990-10       Impact factor: 1.840

3.  Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment.

Authors:  C K Holland; R E Apfel
Journal:  J Acoust Soc Am       Date:  1990-11       Impact factor: 1.840

4.  Evidence for Acoustic Cavitation In Vivo: Thresholds for Bubble Formation with 0.75-MHz Continuous Wave and Pulsed Beams.

Authors:  G R Ter Harr; S Daniels; K Morton
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1986       Impact factor: 2.725

5.  Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro.

Authors:  E C Everbach; I R Makin; M Azadniv; R S Meltzer
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

6.  A new noninvasive technique for cardiac pressure measurement: resonant scattering of ultrasound from bubbles.

Authors:  W M Fairbank; M O Scully
Journal:  IEEE Trans Biomed Eng       Date:  1977-03       Impact factor: 4.538

Review 7.  Hypoplastic left heart syndrome: diagnosis and management.

Authors:  Rachel Andrews; Robert Tulloh
Journal:  Hosp Med       Date:  2002-01

8.  Preoperative management of pulmonary venous hypertension in hypoplastic left heart syndrome with restrictive atrial septal defect.

Authors:  A M Atz; J A Feinstein; R A Jonas; S B Perry; D L Wessel
Journal:  Am J Cardiol       Date:  1999-04-15       Impact factor: 2.778

9.  A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results.

Authors:  R A Roy; A A Atchley; L A Crum; J B Fowlkes; J J Reidy
Journal:  J Acoust Soc Am       Date:  1985-11       Impact factor: 1.840

10.  Acoustic generation of bubbles in excised canine urinary bladders.

Authors:  J B Fowlkes; P L Carson; E H Chiang; J M Rubin
Journal:  J Acoust Soc Am       Date:  1991-06       Impact factor: 1.840

View more
  29 in total

1.  A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.

Authors:  Adam D Maxwell; Tzu-Yin Wang; Lingqian Yuan; Alexander P Duryea; Zhen Xu; Charles A Cain
Journal:  Ultrasound Med Biol       Date:  2010-10-28       Impact factor: 2.998

2.  A new strategy to enhance cavitational tissue erosion using a high-intensity, Initiating sequence.

Authors:  Zhen Xu; J Brian Fowlkes; Charles A Cain
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-08       Impact factor: 2.725

3.  Effects of acoustic parameters on bubble cloud dynamics in ultrasound tissue erosion (histotripsy).

Authors:  Zhen Xu; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  J Acoust Soc Am       Date:  2007-07       Impact factor: 1.840

4.  Optical and acoustic monitoring of bubble cloud dynamics at a tissue-fluid interface in ultrasound tissue erosion.

Authors:  Zhen Xu; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  J Acoust Soc Am       Date:  2007-04       Impact factor: 1.840

5.  Ultrasound attenuation estimation using backscattered echoes from multiple sources.

Authors:  Timothy A Bigelow
Journal:  J Acoust Soc Am       Date:  2008-08       Impact factor: 1.840

6.  High speed imaging of bubble clouds generated in pulsed ultrasound cavitational therapy--histotripsy.

Authors:  Zhen Xu; Mekhala Raghavan; Timothy L Hall; Ching-Wei Chang; Mary-Ann Mycek; J Brian Fowlkes; Charles A Cain
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-10       Impact factor: 2.725

7.  Combined passive detection and ultrafast active imaging of cavitation events induced by short pulses of high-intensity ultrasound.

Authors:  Jérôme Gateau; Jean-François Aubry; Mathieu Pernot; Mathias Fink; Mickaël Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-03       Impact factor: 2.725

8.  Visualizing the Histotripsy Process: Bubble Cloud-Cancer Cell Interactions in a Tissue-Mimicking Environment.

Authors:  Eli Vlaisavljevich; Adam Maxwell; Lauren Mancia; Eric Johnsen; Charles Cain; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2016-07-09       Impact factor: 2.998

9.  Probability of cavitation for single ultrasound pulses applied to tissues and tissue-mimicking materials.

Authors:  Adam D Maxwell; Charles A Cain; Timothy L Hall; J Brian Fowlkes; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2013-02-04       Impact factor: 2.998

10.  Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis.

Authors:  Aiwei Shi; Jonathan Lundt; Zilin Deng; Jonathan Macoskey; Hitinder Gurm; Gabe Owens; Xi Zhang; Timothy L Hall; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2018-09-30       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.