Literature DB >> 1918622

Acoustic generation of bubbles in excised canine urinary bladders.

J B Fowlkes1, P L Carson, E H Chiang, J M Rubin.   

Abstract

A high-intensity, 555-kHz acoustic field was used to generate bubbles within urinary bladders excised from dogs. Following the exposure, bubbles were visualized on a diagnostic ultrasound scanner with a 5-MHz in-line mechanical sector scanhead. Scattering of the high-intensity ultrasound by the bubbles was also observed during the exposure as high-amplitude scan lines. The bladders used had been surgically removed after tying off the ureters and urethra to prevent urine loss and exposure to external contaminants. Each bladder was sealed in a plastic bag filled with a degassed saline solution. The bladder was centered in a sealed degassed water path at the common focus of a 7-cm-diam transducer and a 10-cm-diam brass reflector. The 555-kHz transducer and reflector were both focused at 10 cm and were aligned coaxially. Using various acoustic pressure amplitudes, two, 10-s low-frequency exposures, separated by approximately 30 s, occurred at approximately 2-min intervals. Experiments on a single bladder lasted as long as 45 min. The sizes of the largest bubbles, which were easily imaged, were estimated from rise velocity measurements as 50-70 microns in radius, and pressure amplitudes used to generate those large bubbles were estimated as 10-20 bars. The detection of smaller bubbles was limited by the inability to clearly distinguish bubble echoes from artifacts caused by the reverberant field within the bladder. Visual inspection of the exterior and interior bladder wall showed no significant discoloration within the high intensity beam path.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1918622     DOI: 10.1121/1.400713

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  10 in total

1.  Investigation of intensity thresholds for ultrasound tissue erosion.

Authors:  Zhen Xu; J Brian Fowlkes; Achi Ludomirsky; Charles A Cain
Journal:  Ultrasound Med Biol       Date:  2005-12       Impact factor: 2.998

2.  Effects of acoustic parameters on bubble cloud dynamics in ultrasound tissue erosion (histotripsy).

Authors:  Zhen Xu; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  J Acoust Soc Am       Date:  2007-07       Impact factor: 1.840

3.  Optical and acoustic monitoring of bubble cloud dynamics at a tissue-fluid interface in ultrasound tissue erosion.

Authors:  Zhen Xu; Timothy L Hall; J Brian Fowlkes; Charles A Cain
Journal:  J Acoust Soc Am       Date:  2007-04       Impact factor: 1.840

4.  Removal of residual nuclei following a cavitation event using low-amplitude ultrasound.

Authors:  Alexander P Duryea; Charles A Cain; Hedieh A Tamaddoni; William W Roberts; Timothy L Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-10       Impact factor: 2.725

5.  Removal of residual nuclei following a cavitation event: a parametric study.

Authors:  Alexander P Duryea; Hedieh A Tamaddoni; Charles A Cain; William W Roberts; Timothy L Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-09       Impact factor: 2.725

6.  Removal of residual cavitation nuclei to enhance histotripsy erosion of model urinary stones.

Authors:  Alexander P Duryea; William W Roberts; Charles A Cain; Timothy L Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-05       Impact factor: 2.725

7.  Acoustic Methods for Increasing the Cavitation Initiation Pressure Threshold.

Authors:  Hedieh Alavi Tamaddoni; Alexander P Duryea; Eli Vlaisavljevich; Zhen Xu; Timothy L Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-08-29       Impact factor: 2.725

8.  Histotripsy-induced cavitation cloud initiation thresholds in tissues of different mechanical properties.

Authors:  Eli Vlaisavljevich; Adam Maxwell; Matthew Warnez; Eric Johnsen; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

9.  Size measurement of tissue debris particles generated from pulsed ultrasound cavitational therapy-histotripsy.

Authors:  Zhen Xu; Zhenzhen Fan; Timothy L Hall; Frank Winterroth; J Brian Fowlkes; Charles A Cain
Journal:  Ultrasound Med Biol       Date:  2008-11-21       Impact factor: 2.998

Review 10.  Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children. I. Procedure.

Authors:  Kassa Darge
Journal:  Pediatr Radiol       Date:  2007-07-06