Literature DB >> 16344034

Inter- and intrarater reliability of a back range of motion instrument.

Aimie F Kachingwe1, Beth J Phillips.   

Abstract

OBJECTIVE: To examine the interrater and intrarater reliability of a back range of motion (BROM) instrument when measuring lumbar spine active planar motions and pelvic inclination.
DESIGN: Single-group repeated measures for inter- and intrarater reliability.
SETTING: Academic institution. PARTICIPANTS: Ninety-one participants (61 women, 30 men; mean age, 28 y) without a current complaint of low back pain volunteered. INTERVENTION: Two examiners measured pelvic inclination and all lumbar motions by using the BROM device. Subjects alternated between examiners for 4 complete trials; examiners remained blinded to the measurements. MAIN OUTCOME MEASURES: Intraclass correlation coefficients (ICCs) were used to determine intrarater and interrater reliability. Regression analysis was performed to determine the role palpation played in sagittal plane measurement error.
RESULTS: Intrarater reliability for side bending was good (ICC range, .85-.83), lumbar forward flexion and pelvic inclination was good to fair (ICC range, .84-.79), and extension and rotation was fair to poor (ICC range, .76-.58). Interrater reliability was fair to poor for all lumbar motions and for pelvic inclination (ICC range, .79-.55). Less than 2% of the variation in sagittal plane measurements was explained by consistency of palpation for device placement.
CONCLUSIONS: The BROM provides a reliable means of measuring lumbar forward flexion, side bending, and pelvic inclination when performed by the same examiner in asymptomatic subjects.

Entities:  

Mesh:

Year:  2005        PMID: 16344034     DOI: 10.1016/j.apmr.2005.07.304

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  12 in total

1.  Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing.

Authors:  Liba Sheeran; Valerie Sparkes; Monica Busse; Robert van Deursen
Journal:  Eur Spine J       Date:  2009-12-15       Impact factor: 3.134

2.  Long-term effect of high-intensity laser therapy in the treatment of patients with chronic low back pain: a randomized blinded placebo-controlled trial.

Authors:  Mohamed Salaheldien Mohamed Alayat; Azza Mohamed Atya; Mohamed Mohamed Ebrahim Ali; Tamer Mohamed Shosha
Journal:  Lasers Med Sci       Date:  2013-11-02       Impact factor: 3.161

3.  Reproducibility of global three-dimensional motion during manual atlanto-axial rotation mobilization: an in vitro study.

Authors:  Erik Cattrysse; Steven Provyn; Patrick Kool; Jan Pieter Clarys; Peter Van Roy
Journal:  J Man Manip Ther       Date:  2010-03

4.  Nucleus pulposus deformation in response to lumbar spine lateral flexion: an in vivo MRI investigation.

Authors:  Peter J Fazey; Hiroshi Takasaki; Kevin P Singer
Journal:  Eur Spine J       Date:  2010-03-05       Impact factor: 3.134

5.  Short-term therapeutic effects of 890-nanometer light therapy for chronic low back pain: a double-blind randomized placebo-controlled study.

Authors:  Ru-Lan Hsieh; Wen-Chung Lee
Journal:  Lasers Med Sci       Date:  2013-07-03       Impact factor: 3.161

6.  Reliability of thoracic spine rotation range-of-motion measurements in healthy adults.

Authors:  Katherine D Johnson; Kyung-Min Kim; Byung-Kyu Yu; Susan A Saliba; Terry L Grindstaff
Journal:  J Athl Train       Date:  2012 Jan-Feb       Impact factor: 2.860

7.  Normative Reference Values for Trunk Range of Motion and Isometric Muscle Strength in Asymptomatic Young Indian Adults.

Authors:  Gautam M Shetty; Shikha Jain; Pratiksha Munje; Anita Bhan; C S Ram
Journal:  Indian J Orthop       Date:  2021-07-27       Impact factor: 1.033

8.  The validity of spinal mobility for prediction of functional disability in male patients with low back pain.

Authors:  Azza M Atya
Journal:  J Adv Res       Date:  2012-02-16       Impact factor: 10.479

9.  The effects of the Mulligan Sustained Natural Apophyseal Glide (SNAG) mobilisation in the lumbar flexion range of asymptomatic subjects as measured by the Zebris CMS20 3-D motion analysis system.

Authors:  Maria Moutzouri; Evdokia Billis; Nikolaos Strimpakos; Polixeni Kottika; Jacqueline A Oldham
Journal:  BMC Musculoskelet Disord       Date:  2008-10-01       Impact factor: 2.362

10.  A Wearable Device Based on a Fiber Bragg Grating Sensor for Low Back Movements Monitoring.

Authors:  Martina Zaltieri; Carlo Massaroni; Daniela Lo Presti; Marco Bravi; Riccardo Sabbadini; Sandra Miccinilli; Silvia Sterzi; Domenico Formica; Emiliano Schena
Journal:  Sensors (Basel)       Date:  2020-07-09       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.