Literature DB >> 22488230

Reliability of thoracic spine rotation range-of-motion measurements in healthy adults.

Katherine D Johnson1, Kyung-Min Kim, Byung-Kyu Yu, Susan A Saliba, Terry L Grindstaff.   

Abstract

CONTEXT: The reliability of clinical techniques to quantify thoracic spine rotation range of motion (ROM) has not been evaluated.
OBJECTIVE: To determine the intratester and intertester reliability of 5 thoracic rotation measurement techniques.
DESIGN: Descriptive laboratory study.
SETTING: University research laboratory. PATIENTS OR OTHER PARTICIPANTS: Forty-six healthy volunteers (age = 23.6 ± 4.3 years, height = 171.0 ± 9.6 cm, mass = 71.4 ± 16.7 kg). MAIN OUTCOME MEASURE(S): We tested 5 thoracic rotation ROM techniques over 2 days: seated rotation (bar in back and front), half-kneeling rotation (bar in back and front), and lumbar-locked rotation. On day 1, 2 examiners obtained 2 sets of measurements (sessions 1, 2) to determine the within-session intertester reliability and within-day intratester reliability. A single examiner obtained measurements on day 2 (session 3) to determine the intratester reliability between days. Each technique was performed 3 times per side, and averages were used for data analysis. Reliability was determined using intraclass correlation coefficients, standard error of measurement (SEM), and minimal detectable change (MDC). Differences between raters during session 1 were determined using paired t tests.
RESULTS: Within-session intertester reliability estimates ranged from 0.85 to 0.94. Ranges for the SEM were 1.0° to 2.3° and for the MDC were 2.8° to 6.3°. No differences were seen between examiners during session 1 for seated rotation (bar in front, both sides), half-kneeling rotation (bar in front, left side), or the lumbar locked position (both sides) (all values of P > .05). Within-day intratester reliability estimates ranged from 0.86 to 0.95. Ranges for the SEM were 0.8° to 2.1° and for the MDC were 2.1 ° to 5.9°. Between-days intratester reliability estimates ranged from 0.84 to 0.91. Ranges for the SEM were 1.4° to 2.0° and for the MDC were 3.9° to 5.6°.
CONCLUSIONS: All techniques had good reliability and low levels of measurement error. The seated rotation, bar in front, and lumbar-locked rotation tests may be used reliably when more than 1 examiner is obtaining measurements.

Entities:  

Mesh:

Year:  2012        PMID: 22488230      PMCID: PMC3418115          DOI: 10.4085/1062-6050-47.1.52

Source DB:  PubMed          Journal:  J Athl Train        ISSN: 1062-6050            Impact factor:   2.860


  20 in total

1.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literature.

Authors:  Anne F Mannion; Katrin Knecht; Gordana Balaban; Jiri Dvorak; Dieter Grob
Journal:  Eur Spine J       Date:  2003-12-06       Impact factor: 3.134

3.  A comparative study of computed tomographic and plain radiographic methods to measure vertebral rotation in adolescent idiopathic scoliosis.

Authors:  E K Ho; S S Upadhyay; L Ferris; F L Chan; J Bacon-Shone; L C Hsu; J C Leong
Journal:  Spine (Phila Pa 1976)       Date:  1992-07       Impact factor: 3.468

4.  A comparison of four computerized methods for measuring vertebral rotation.

Authors:  G G Russell; V J Raso; D Hill; J McIvor
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

5.  Thoracic rotation measurement techniques: clinical commentary.

Authors:  Katherine D Johnson; Terry L Grindstaff
Journal:  N Am J Sports Phys Ther       Date:  2010-12

6.  Measures of shoulder protraction and thoracolumbar rotation.

Authors:  M Schenkman; K C Laub; M Kuchibhatla; L Ray; M Shinberg
Journal:  J Orthop Sports Phys Ther       Date:  1997-05       Impact factor: 4.751

7.  Measurement of spinal posture and range of spinal movement.

Authors:  W Y Loebl
Journal:  Ann Phys Med       Date:  1967-08

8.  Intrarater reliability of CROM measurement of cervical spine active range of motion in persons with and without neck pain.

Authors:  James P Fletcher; William D Bandy
Journal:  J Orthop Sports Phys Ther       Date:  2008-10       Impact factor: 4.751

9.  Stability and intra-tester reliability of an in vivo measurement of thoracic axial rotation using an innovative methodology.

Authors:  Nicola R Heneghan; Alison Hall; Mark Hollands; George M Balanos
Journal:  Man Ther       Date:  2008-11-30

10.  Ultrasound measurement of vertebral rotation in idiopathic scoliosis.

Authors:  S Suzuki; T Yamamuro; J Shikata; K Shimizu; H Iida
Journal:  J Bone Joint Surg Br       Date:  1989-03
View more
  23 in total

1.  Thoracic region self-mobilization: a clinical suggestion.

Authors:  Katherine D Johnson; Terry L Grindstaff
Journal:  Int J Sports Phys Ther       Date:  2012-04

2.  ROLLING REVISITED: USING ROLLING TO ASSESS AND TREAT NEUROMUSCULAR CONTROL AND COORDINATION OF THE CORE AND EXTREMITIES OF ATHLETES.

Authors:  Barbara J Hoogenboom; Michael L Voight
Journal:  Int J Sports Phys Ther       Date:  2015-11

3.  Spinal-Exercise Prescription in Sport: Classifying Physical Training and Rehabilitation by Intention and Outcome.

Authors:  Simon Spencer; Alex Wolf; Alison Rushton
Journal:  J Athl Train       Date:  2016-09-23       Impact factor: 2.860

4.  The reliability and validity of a designed setup for the assessment of static back extensor force and endurance in older women with and without hyperkyphosis.

Authors:  Taybeh Roghani; Minoo Khalkhali Zavieh; Abbas Rahimi; Saeed Talebian; Farideh Dehghan Manshadi; Alireza Akbarzadeh Baghban; Nicole King; Wendy Katzman
Journal:  Physiother Theory Pract       Date:  2018-01-25       Impact factor: 2.279

5.  Shoulder Pain and Rotational Range of Motion of the Trunk, Shoulder, and Hip in Baseball Players.

Authors:  Yeol-Oh Kim; Yoon-Ju Jo; Si-Hyun Kim; Kyue-Nam Park
Journal:  J Athl Train       Date:  2019-09-04       Impact factor: 2.860

6.  Validity of the Digital Inclinometer and iPhone When Measuring Thoracic Spine Rotation.

Authors:  Jonathan Bucke; Simon Spencer; Louise Fawcett; Lawrence Sonvico; Alison Rushton; Nicola R Heneghan
Journal:  J Athl Train       Date:  2017-08-08       Impact factor: 2.860

7.  Treatment of nonspecific thoracic spine pain with trigger point dry needling and intramuscular electrical stimulation: a case series.

Authors:  Jodie M Rock; Charles E Rainey
Journal:  Int J Sports Phys Ther       Date:  2014-10

8.  The use of trigger point dry needling and intramuscular electrical stimulation for a subject with chronic low back pain: a case report.

Authors:  Charles E Rainey
Journal:  Int J Sports Phys Ther       Date:  2013-04

9.  THE EFFECT of ONE-ON-ONE INTERVENTION in ATHLETES with MULTIPLE RISK FACTORS for INJURY.

Authors:  Kate Schwartzkopf-Phifer; Robert A English; Carl G Mattacola; Emily V Dressler; Kyle B Kiesel
Journal:  Int J Sports Phys Ther       Date:  2019-06

10.  THE RELATIONSHIP BETWEEN SEGMENTAL ROLLING ABILITY AND LUMBAR MULTIFIDUS ACTIVATION TIME.

Authors:  Nicole Clark; Michael L Voight; Ashley M Campbell; Sherry Pierce; Pat Sells; Ryan Cook; Clint Henley; Lindsey Schiller
Journal:  Int J Sports Phys Ther       Date:  2017-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.