Literature DB >> 16343959

Synchronized detection of minute electrical currents with MRI using Lorentz effect imaging.

Trong-Kha Truong1, Jennifer L Wilbur, Allen W Song.   

Abstract

The blood oxygenation level-dependent (BOLD) effect is the most commonly used contrast mechanism in functional magnetic resonance imaging (fMRI), due to its relatively high spatial resolution and sensitivity. However, the ability of BOLD fMRI to accurately localize neuronal activation in space and time is limited by the inherent hemodynamic modulation. There is hence a need to develop alternative MRI methods that can directly image neuroelectric activity, thereby achieving both a high temporal resolution and spatial specificity as compared to conventional BOLD fMRI. In this paper, we extend the Lorentz effect imaging technique, which can detect spatially incoherent yet temporally synchronized minute electrical activity in a strong magnetic field, and demonstrate its feasibility for imaging randomly oriented electrical currents on the order of microamperes with a temporal resolution on the order of milliseconds in gel phantoms. This constitutes a promising step towards its application to direct imaging of neuroelectric activity in vivo, which has the same order of current density and temporal synchrony.

Mesh:

Substances:

Year:  2005        PMID: 16343959      PMCID: PMC1540538          DOI: 10.1016/j.jmr.2005.11.012

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  14 in total

1.  MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: a model for direct detection of neuronal currents in the brain.

Authors:  Daniel Konn; Penny Gowland; Richard Bowtell
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

2.  Current-induced magnetic resonance phase imaging.

Authors:  J Bodurka; A Jesmanowicz; J S Hyde; H Xu; L Estkowski; S J Li
Journal:  J Magn Reson       Date:  1999-03       Impact factor: 2.229

3.  Hunting for neuronal currents: absence of rapid MRI signal changes during visual-evoked response.

Authors:  Renxin Chu; Jacco A de Zwart; Peter van Gelderen; Masaki Fukunaga; Peter Kellman; Tom Holroyd; Jeff H Duyn
Journal:  Neuroimage       Date:  2004-11       Impact factor: 6.556

4.  Initial attempts at directly detecting alpha wave activity in the brain using MRI.

Authors:  Daniel Konn; Sean Leach; Penny Gowland; Richard Bowtell
Journal:  Magn Reson Imaging       Date:  2004-12       Impact factor: 2.546

5.  Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents.

Authors:  Marta Bianciardi; Francesco Di Russo; Teresa Aprile; Bruno Maraviglia; Gisela E Hagberg
Journal:  Magn Reson Imaging       Date:  2004-12       Impact factor: 2.546

6.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Authors:  K K Kwong; J W Belliveau; D A Chesler; I E Goldberg; R M Weisskoff; B P Poncelet; D N Kennedy; B E Hoppel; M S Cohen; R Turner
Journal:  Proc Natl Acad Sci U S A       Date:  1992-06-15       Impact factor: 11.205

7.  Time course EPI of human brain function during task activation.

Authors:  P A Bandettini; E C Wong; R S Hinks; R S Tikofsky; J S Hyde
Journal:  Magn Reson Med       Date:  1992-06       Impact factor: 4.668

8.  Limitations of temporal resolution in functional MRI.

Authors:  S G Kim; W Richter; K Uğurbil
Journal:  Magn Reson Med       Date:  1997-04       Impact factor: 4.668

9.  Event-related fMRI and the hemodynamic response.

Authors:  R L Buckner
Journal:  Hum Brain Mapp       Date:  1998       Impact factor: 5.038

10.  Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at 1.5T: preliminary results.

Authors:  S Lai; A L Hopkins; E M Haacke; D Li; B A Wasserman; P Buckley; L Friedman; H Meltzer; P Hedera; R Friedland
Journal:  Magn Reson Med       Date:  1993-09       Impact factor: 4.668

View more
  8 in total

1.  Finding neuroelectric activity under magnetic-field oscillations (NAMO) with magnetic resonance imaging in vivo.

Authors:  Trong-Kha Truong; Allen W Song
Journal:  Proc Natl Acad Sci U S A       Date:  2006-08-07       Impact factor: 11.205

2.  Direct magnetic resonance detection of neuronal electrical activity.

Authors:  Natalia Petridou; Dietmar Plenz; Afonso C Silva; Murray Loew; Jerzy Bodurka; Peter A Bandettini
Journal:  Proc Natl Acad Sci U S A       Date:  2006-10-12       Impact factor: 11.205

Review 3.  The role of magnetic forces in biology and medicine.

Authors:  Bradley J Roth
Journal:  Exp Biol Med (Maywood)       Date:  2011-02

4.  Direct detection of a single evoked action potential with MRS in Lumbricus terrestris.

Authors:  Alexander J Poplawsky; Raymond Dingledine; Xiaoping P Hu
Journal:  NMR Biomed       Date:  2011-07-05       Impact factor: 4.044

5.  Electromagnetohydrodynamic modeling of Lorentz effect imaging.

Authors:  Navid Pourtaheri; Trong-Kha Truong; Craig S Henriquez
Journal:  J Magn Reson       Date:  2013-08-28       Impact factor: 2.229

6.  Magnetic resonance imaging of ionic currents in solution: the effect of magnetohydrodynamic flow.

Authors:  Mukund Balasubramanian; Robert V Mulkern; William M Wells; Padmavathi Sundaram; Darren B Orbach
Journal:  Magn Reson Med       Date:  2014-10-01       Impact factor: 4.668

7.  Mechanical model of neural tissue displacement during Lorentz effect imaging.

Authors:  Bradley J Roth; Peter J Basser
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

8.  The movement of a nerve in a magnetic field: application to MRI Lorentz effect imaging.

Authors:  Bradley J Roth; Adam Luterek; Steffan Puwal
Journal:  Med Biol Eng Comput       Date:  2014-04-12       Impact factor: 2.602

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.