Literature DB >> 15528106

Hunting for neuronal currents: absence of rapid MRI signal changes during visual-evoked response.

Renxin Chu1, Jacco A de Zwart, Peter van Gelderen, Masaki Fukunaga, Peter Kellman, Tom Holroyd, Jeff H Duyn.   

Abstract

While recent reports have advocated the use of magnetic resonance imaging (MRI) to detect the effects of neuronal currents associated with human brain activity, only preliminary experimental data have been presented so far to demonstrate the feasibility of the method. Furthermore, it has not been adequately demonstrated that (1) MRI can separate neuronal current (NC) effects from other effects such as blood oxygen level-dependent (BOLD) contrast; (2) MRI has adequate sensitivity to detect NCs in vivo. In this work, we introduce a method that can separate slow (e.g., BOLD) processes from potential rapid (e.g., NC) processes and apply this method to investigate whether MRI allows detection of an NC response to a visual stimulus. MRI studies (n = 8) at 3.0 T using a sensitive multichannel detector showed insignificant effects related to NCs (averaged t < 0.05), in the presence of a highly significant BOLD signal (t = 6.15 +/- 0.90). In contrast, magnetoencephalography (MEG) experiments performed under similar conditions on the same subjects showed highly significant electrical activity (t = 7.90 +/- 2.28). It is concluded that, under the conditions used in this study, the sensitivity of MRI to detect evoked responses through NCs is at least an order of magnitude below that of BOLD-based functional MRI (fMRI) or MEG and too low to be practically useful.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15528106     DOI: 10.1016/j.neuroimage.2004.07.003

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  24 in total

1.  Magnetic resonance imaging of oscillating electrical currents.

Authors:  Nicholas W Halpern-Manners; Vikram S Bajaj; Thomas Z Teisseyre; Alexander Pines
Journal:  Proc Natl Acad Sci U S A       Date:  2010-04-26       Impact factor: 11.205

2.  Synchronized detection of minute electrical currents with MRI using Lorentz effect imaging.

Authors:  Trong-Kha Truong; Jennifer L Wilbur; Allen W Song
Journal:  J Magn Reson       Date:  2005-12-15       Impact factor: 2.229

3.  Finding neuroelectric activity under magnetic-field oscillations (NAMO) with magnetic resonance imaging in vivo.

Authors:  Trong-Kha Truong; Allen W Song
Journal:  Proc Natl Acad Sci U S A       Date:  2006-08-07       Impact factor: 11.205

4.  Measurement of weak electric currents in copper wire phantoms using MRI: influence of susceptibility enhancement.

Authors:  Ruiwang Huang; Oleg Posnansky; Abdullah Celik; Ana-Maria Oros-Peusquens; Veronika Ermer; Marco Irkens; H-Peter Wegener; N Jon Shah
Journal:  MAGMA       Date:  2006-07-25       Impact factor: 2.310

5.  Direct magnetic resonance detection of neuronal electrical activity.

Authors:  Natalia Petridou; Dietmar Plenz; Afonso C Silva; Murray Loew; Jerzy Bodurka; Peter A Bandettini
Journal:  Proc Natl Acad Sci U S A       Date:  2006-10-12       Impact factor: 11.205

6.  Modeling direct effects of neural current on MRI.

Authors:  Leon Heller; Benjamin E Barrowes; John S George
Journal:  Hum Brain Mapp       Date:  2009-01       Impact factor: 5.038

7.  Failure to direct detect magnetic field dephasing corresponding to ERP generation.

Authors:  Lin Tang; Malcolm J Avison; James C Gatenby; John C Gore
Journal:  Magn Reson Imaging       Date:  2008-01-03       Impact factor: 2.546

8.  Stimulus-induced Rotary Saturation (SIRS): a potential method for the detection of neuronal currents with MRI.

Authors:  Thomas Witzel; Fa-Hsuan Lin; Bruce R Rosen; Lawrence L Wald
Journal:  Neuroimage       Date:  2008-05-20       Impact factor: 6.556

9.  Is it possible to detect dendrite currents using presently available magnetic resonance imaging techniques?

Authors:  William I Jay; Ranjith S Wijesinghe; Brain D Dolasinski; Bradley J Roth
Journal:  Med Biol Eng Comput       Date:  2012-03-24       Impact factor: 2.602

10.  Characterization of non-hemodynamic functional signal measured by spin-lock fMRI.

Authors:  Tao Jin; Seong-Gi Kim
Journal:  Neuroimage       Date:  2013-04-22       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.