In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: preliminary results.

Andrea Giovanni Cutti1, Angelo Cappello, Angelo Davalli.   

Abstract

BACKGROUND: Soft tissue artefact is the dominant error source for upper extremity motion analyses that use skin-mounted markers, especially in humeral axial rotation.
METHODS: A new in vivo technique is presented that is based on the definition of a humerus bone-embedded frame almost "artefact free" but influenced by the elbow orientation in the measurement of the humeral axial rotation, and on an algorithm designed to solve this kinematic coupling. The technique was validated in vivo in a study of six healthy subjects who performed five arm-movement tasks. For each task the similarity between a gold standard pattern and the axial rotation pattern before and after the application of the compensation algorithm was evaluated in terms of explained variance, gain, phase and offset. In addition the root mean square error between the patterns was used as a global similarity estimator.
FINDINGS: After the application, for four out of five tasks, patterns were highly correlated, in phase, with almost equal gain and limited offset; the root mean square error decreased from the original 9 degrees to 3 degrees .
INTERPRETATION: The proposed technique appears to help compensate for the soft tissue artefact affecting axial rotation. A further development is also proposed to make the technique effective also for the pure prono-supination task.

Entities:  

Mesh:

Year:  2005        PMID: 16330137     DOI: 10.1016/j.clinbiomech.2005.09.018

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  9 in total

1.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

2.  Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre.

Authors:  Amity Cree Campbell; J A Alderson; D G Lloyd; B C Elliott
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

3.  IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Authors:  Mahdi Zabat; Amina Ababou; Noureddine Ababou; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2019-08-30       Impact factor: 2.602

4.  Compensating for Soft-Tissue Artifact Using the Orientation of Distal Limb Segments During Electromagnetic Motion Capture of the Upper Limb.

Authors:  Zachary Bons; Taylor Dickinson; Ryan Clark; Kari Beardsley; Steven K Charles
Journal:  J Biomech Eng       Date:  2022-07-01       Impact factor: 1.899

5.  An alternative technical marker set for the pelvis is more repeatable than the standard pelvic marker set.

Authors:  Maedeh Borhani; Alison H McGregor; Anthony M J Bull
Journal:  Gait Posture       Date:  2013-06-19       Impact factor: 2.840

6.  A Wide-Range, Wireless Wearable Inertial Motion Sensing System for Capturing Fast Athletic Biomechanics in Overhead Pitching.

Authors:  Michael Lapinski; Carolina Brum Medeiros; Donna Moxley Scarborough; Eric Berkson; Thomas J Gill; Thomas Kepple; Joseph A Paradiso
Journal:  Sensors (Basel)       Date:  2019-08-21       Impact factor: 3.576

7.  The use of inertial sensors system for human motion analysis.

Authors:  Antonio I Cuesta-Vargas; Alejandro Galán-Mercant; Jonathan M Williams
Journal:  Phys Ther Rev       Date:  2010-12

8.  Forearm pressure distribution during ambulation with elbow crutches: a cross-sectional study.

Authors:  Jonas Fischer; Corina Nüesch; Beat Göpfert; Annegret Mündermann; Victor Valderrabano; Thomas Hügle
Journal:  J Neuroeng Rehabil       Date:  2014-04-15       Impact factor: 4.262

9.  Effects of Internal Fixation for Mid-Shaft Clavicle Fractures on Shoulder Kinematics During Humeral Elevations.

Authors:  Li-Wei Hung; Hsuan-Yu Lu; Chung-Hsun Chang; Tsan-Yang Chen; Ting-Ming Wang; Tung-Wu Lu
Journal:  Front Bioeng Biotechnol       Date:  2021-07-22
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.