Compensating for Soft-Tissue Artifact Using the Orientation of Distal Limb Segments During Electromagnetic Motion Capture of the Upper Limb.

Zachary Bons1, Taylor Dickinson1, Ryan Clark1, Kari Beardsley1, Steven K Charles2.   

Abstract

Most motion capture measurements suffer from soft-tissue artifacts (STA). Especially affected are rotations about the long axis of a limb segment, such as humeral internal-external rotation (HIER) and forearm pronation-supination (FPS). Unfortunately, most existing methods to compensate for STA were designed for optoelectronic motion capture systems. We present and evaluate an STA compensation method that (1) compensates for STA in HIER and/or FPS, (2) is developed specifically for electromagnetic motion capture systems, and (3) does not require additional calibration or data. To compensate for STA, calculation of HIER angles relies on forearm orientation, and calculation of FPS angles rely on hand orientation. To test this approach, we recorded whole-arm movement data from eight subjects and compared their joint angle trajectories calculated according to progressive levels of STA compensation. Compensated HIER and FPS angles were significantly larger than uncompensated angles. Although the effect of STA compensation on other joint angles (besides HIER and FPS) was usually modest, significant effects were seen in certain degrees-of-freedom under some conditions. Overall, the method functioned as intended during most of the range of motion of the upper limb, but it becomes unstable in extreme elbow extension and extreme wrist flexion-extension. Specifically, this method is not recommended for movements within 20 deg of full elbow extension, full wrist flexion, or full wrist extension. Since this method does not require additional calibration of data, it can be applied retroactively to data collected without the intent to compensate for STA.
Copyright © 2022 by ASME.

Entities:  

Mesh:

Year:  2022        PMID: 34951462      PMCID: PMC8883122          DOI: 10.1115/1.4053366

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   1.899


  26 in total

Review 1.  Review of arm motion analyses.

Authors:  C Anglin; U P Wyss
Journal:  Proc Inst Mech Eng H       Date:  2000       Impact factor: 1.617

2.  Effects of varying backpack loads on peak forces in the lumbosacral spine during walking.

Authors:  J-H Goh; A Thambyah; K Bose
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998       Impact factor: 2.063

3.  Soft tissue artefact assessment in humeral axial rotation.

Authors:  Andrea Giovanni Cutti; Gabriele Paolini; Marco Troncossi; Angelo Cappello; Angelo Davalli
Journal:  Gait Posture       Date:  2005-04       Impact factor: 2.840

4.  Complete 3D kinematics of upper extremity functional tasks.

Authors:  Carolien J van Andel; Nienke Wolterbeek; Caroline A M Doorenbosch; DirkJan H E J Veeger; Jaap Harlaar
Journal:  Gait Posture       Date:  2007-04-24       Impact factor: 2.840

5.  Advantages of optical compared with electromagnetic tracking.

Authors:  Neil D Glossop
Journal:  J Bone Joint Surg Am       Date:  2009-02       Impact factor: 5.284

6.  Electromagnetic tracking in the clinical environment.

Authors:  Ziv Yaniv; Emmanuel Wilson; David Lindisch; Kevin Cleary
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

7.  Can the effect of soft tissue artifact be eliminated in upper-arm internal-external rotation?

Authors:  Yanxin Zhang; David G Lloyd; Amity C Campbell; Jacqueline A Alderson
Journal:  J Appl Biomech       Date:  2011-08       Impact factor: 1.833

8.  Polhemus EM tracked Micro Sensor for CT-guided interventions.

Authors:  Alfred M Franz; Alexander Seitel; Dominique Cheray; Lena Maier-Hein
Journal:  Med Phys       Date:  2018-12-04       Impact factor: 4.071

9.  Reliability and Validity of the Polhemus Liberty System for Upper Body Segment and Joint Angular Kinematics of Elite Golfers.

Authors:  Matilda Jane Wheare; Maximillian J Nelson; Ryan Lumsden; Alec Buttfield; Robert George Crowther
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

10.  Validation of a Kinect V2 based rehabilitation game.

Authors:  Mengxuan Ma; Rachel Proffitt; Marjorie Skubic
Journal:  PLoS One       Date:  2018-08-24       Impact factor: 3.240

View more
  1 in total

1.  Smart Brace for Static and Dynamic Knee Laxity Measurement.

Authors:  Paolo Bellitti; Michela Borghetti; Nicola Francesco Lopomo; Emilio Sardini; Mauro Serpelloni
Journal:  Sensors (Basel)       Date:  2022-08-04       Impact factor: 3.847

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.