Literature DB >> 16319749

A new stand-alone anterior lumbar interbody fusion device: biomechanical comparison with established fixation techniques.

Christopher M J Cain1, Philip Schleicher, Rene Gerlach, Robert Pflugmacher, Matti Scholz, Frank Kandziora.   

Abstract

STUDY
DESIGN: Established lumbar fixation methods were assessed biomechanically, and a comparison was made with a new stand-alone anterior lumbar interbody cage device incorporating integrated anterior fixation.
OBJECTIVES: To compare the stability of a new stand-alone anterior implant (Test-device) with established fixation methods to assess its suitability for clinical use. Our hypothesis being that the Test-device would provide stability comparable to that provided by an anterior cage when supplemented with posterior pedicle screw fixation. SUMMARY OF BACKGROUND DATA: It is accepted that the use of rigid pedicle screw instrumentation increases the chance of achieving a solid fusion, but its use may be associated with a significant increase in postoperative morbidity caused by disruption of the posterior musculature. It is also evident that this increased fusion rate is generally not associated with increased clinical success. This dilemma has led to a search for a solution and to the development of the Test-device anterior lumbar interbody device.
METHODS: The kinematic properties of either the L3-L4 or L4-L5 lumbar motion segment of 8 cadaveric lumbar spines have been tested using the following sequence of fixation: intact, Test-device, Test-device and translaminar facet screws (TS), Cage and TS, Cage and Universal Spine System (USS), and Cage and small stature USS.
RESULTS: All fixation techniques except the cage and TS decreased (P < 0.05) range of motion (ROM), neutral zone (NZ), and elastic zone (EZ), and increased (P < 0.05) stiffness in comparison to the intact motion segment in all test modes. There was a significant increase (P < 0.01) in the ROM, NZ, and EZ, and decrease in the stiffness of the cage and TS group in comparison to all other stabilization techniques in flexion and rotation. There was no significant difference in the ROM, NZ, EZ, and stiffness between the Test-device and cage and USS groups in flexion, extension, and bending. The Test-device resulted in a significantly lower EZ (P < 0.05) and a significantly higher stiffness (P < 0.05) in rotation than all other fixation methods.
CONCLUSIONS: The Test-device alone provided similar and the Test-device and TS higher stability than the pedicle screw constructs evaluated. These results support progression to clinical trials using the Test-device as a stand-alone implant.

Mesh:

Year:  2005        PMID: 16319749     DOI: 10.1097/01.brs.0000187897.25889.54

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  22 in total

1.  Anterior lumbar interbody fusion with stand-alone interbody cage in treatment of lumbar intervertebral foraminal stenosis : comparative study of two different types of cages.

Authors:  Chul-Bum Cho; Kyeong-Sik Ryu; Chun-Kun Park
Journal:  J Korean Neurosurg Soc       Date:  2010-05-31

2.  Biomechanical comparison of two different concepts for stand alone anterior lumbar interbody fusion.

Authors:  Philipp Schleicher; R Gerlach; B Schär; C M J Cain; W Achatz; R Pflugmacher; N P Haas; F Kandziora
Journal:  Eur Spine J       Date:  2008-10-08       Impact factor: 3.134

Review 3.  [Intervertebral cages from a biomechanical point of view].

Authors:  W Schmoelz; A Keiler
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

4.  Evolution of Design of Interbody Cages for Anterior Lumbar Interbody Fusion.

Authors:  Kevin Phan; Ralph J Mobbs
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

Review 5.  Comparison of ALIF vs. XLIF for L4/5 interbody fusion: pros, cons, and literature review.

Authors:  Mark J Winder; Shanu Gambhir
Journal:  J Spine Surg       Date:  2016-03

6.  Integrated Fixation Cage Loosening Under Fatigue Loading.

Authors:  Srinidhi Nagaraja; Vivek Palepu
Journal:  Int J Spine Surg       Date:  2017-06-28

7.  Fusion and subsidence rate of stand alone anterior lumbar interbody fusion using PEEK cage with recombinant human bone morphogenetic protein-2.

Authors:  Eyal Behrbalk; Ofir Uri; Ruth M Parks; Rachel Musson; Reuben Chee Cheong Soh; Bronek Maximilian Boszczyk
Journal:  Eur Spine J       Date:  2013-08-19       Impact factor: 3.134

8.  A new zero-profile implant for stand-alone anterior cervical interbody fusion.

Authors:  M Scholz; K J Schnake; A Pingel; R Hoffmann; F Kandziora
Journal:  Clin Orthop Relat Res       Date:  2011-03       Impact factor: 4.176

9.  [Experiences with PMMA cement as a stand-alone intervertebral spacer. Percutaneous cement discoplasty in the case of vacuum phenomenon within lumbar intervertebral discs].

Authors:  P P Varga; G Jakab; I B Bors; A Lazary; Z Szövérfi
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

10.  [Monosegmental anterior lumbar interbody fusion with the SynFix-LR™ device. A prospective 2-year follow-up study].

Authors:  E Hoff; P Strube; C Gross; T Hartwig; M Putzier
Journal:  Orthopade       Date:  2010-11       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.