Literature DB >> 16302630

Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine.

Jonathan J Carmouche1, Robert W Molinari, Tad Gerlinger, John Devine, Troy Patience.   

Abstract

OBJECT: The authors evaluated the effects of pilot hole preparation technique on insertional torque and axial pullout resistance in osteoporotic thoracic and lumbar vertebrae.
METHODS: Using a probe technique and fluoroscopy, 102 pedicle screws were placed in 51 dual-energy x-ray absorptiometry-proven osteoporotic thoracic and lumbar levels. Screws were inserted using the same-size tapping, one-size-under tapping, or no-tapping technique. Insertional torque and axial pullout resistance were measured. Analysis of variance, Fisher exact test, and regression analysis were performed. Same-size tapping decreased pullout resistance in the lumbar spine. There was no effect on pullout resistance in the thoracic spine. Pullout resistance values were lower for all insertion techniques in the upper thoracic spine. Insertional torque and bone mineral density correlated with pullout resistance in the thoracic and lumbar spine.
CONCLUSIONS: Tapping decreased pedicle screw pullout resistance in the osteoporotic human lumbar spine, although it did not affect pullout strength in the thoracic spine. Tapping decreased insertional torque in upper thoracic levels. Surgeons should optimize overall construct rigidity when placing thoracic pedicle screws in patients with spinal segment osteoporosis.

Entities:  

Mesh:

Year:  2005        PMID: 16302630     DOI: 10.3171/spi.2005.3.5.0364

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  18 in total

1.  Effect of surgical factors on the augmentation of cement-injectable cannulated pedicle screw fixation by a novel calcium phosphate-based nanocomposite.

Authors:  Haolin Sun; Chun Liu; Shunlun Chen; Yanjie Bai; Huilin Yang; Chunde Li; Lei Yang
Journal:  Front Med       Date:  2019-09-23       Impact factor: 4.592

Review 2.  [Stabilization of the osteoporotic spine from a biomechanical viewpoint].

Authors:  C-E Heyde; A Rohlmann; U Weber; R Kayser
Journal:  Orthopade       Date:  2010-04       Impact factor: 1.087

3.  Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?

Authors:  Serkan Erkan; Brian Hsu; Chunhui Wu; Amir A Mehbod; John Perl; Ensor E Transfeldt
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

Review 4.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

5.  Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface.

Authors:  Patrícia Silva; Rodrigo César Rosa; Antonio Carlos Shimano; Helton L A Defino
Journal:  Eur Spine J       Date:  2013-05-08       Impact factor: 3.134

6.  In vivo preclinical evaluation of the influence of osteoporosis on the anchorage of different pedicle screw designs.

Authors:  Gianluca Giavaresi; Milena Fini; Roberto Giardino; Francesca Salamanna; Maria Sartori; Veronica Borsari; Silvia Spriano; Chiara M Bellini; Marco Brayda-Bruno
Journal:  Eur Spine J       Date:  2011-05-05       Impact factor: 3.134

7.  The role of bone mineral density in adult spinal deformity patients undergoing corrective surgery: a matched analysis.

Authors:  Syed I Khalid; Ravi S Nunna; Jennifer S Smith; Rachyl M Shanker; Alecia A Cherney; Kyle B Thomson; Sai Chilakapati; Ankit I Mehta; Owoicho Adogwa
Journal:  Acta Neurochir (Wien)       Date:  2022-08-04       Impact factor: 2.816

8.  EFFECT OF PILOT HOLE TAPPING ON PULLOUT STRENGTH AND INSERTION TORQUE OF DUAL CORE PEDICLE SCREWS.

Authors:  Rodrigo César Rosa; Patrícia Silva; Maurício José Falcai; Antônio Carlos Shimano; Helton Luiz Aparecido Defino
Journal:  Rev Bras Ortop       Date:  2015-11-16

9.  Currently Adopted Criteria for Pedicle Screw Diameter Selection.

Authors:  Giovanni F Solitro; Keith Whitlock; Farid Amirouche; Ankit I Mehta; Annie McDonnell
Journal:  Int J Spine Surg       Date:  2019-04-30

10.  Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone.

Authors:  Wen-Chi Tsai; Po-Quang Chen; Tung-Wu Lu; Shing-Sheng Wu; Kao-Shang Shih; Shang-Chih Lin
Journal:  BMC Musculoskelet Disord       Date:  2009-04-30       Impact factor: 2.362

View more