Literature DB >> 16279067

Computed tomography simulation with superquadrics.

Jiehua Zhu1, Shiying Zhao, Yangbo Ye, Ge Wang.   

Abstract

Accurate and efficient simulation of an x-ray transform for representative structures plays an important role in research and development of x-ray CT, for the evaluation and improvement of CT image reconstruction algorithms, in particular. Superquadrics are a family of three-dimensional objects, which can be used to model a variety of anatomical structures. In this paper, we propose an algorithm for the computation of x-ray transforms for superellipsoids and tori with a monochromatic x-ray. Their usefulness is demonstrated by projection and reconstruction of a superquadric-based thorax phantom. Our work indicates that superquadric modeling provides a more realistic visualization than quadratic modeling, and a faster computation than spline methods.

Mesh:

Year:  2005        PMID: 16279067     DOI: 10.1118/1.2040727

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories.

Authors:  Pankaj Mishra; Sara St James; W Paul Segars; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

Authors:  Jang-Hwan Choi; Rebecca Fahrig; Andreas Keil; Thor F Besier; Saikat Pal; Emily J McWalter; Gary S Beaupré; Andreas Maier
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

4.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

Authors:  W Paul Segars; Benjamin M W Tsui
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009-12       Impact factor: 10.961

5.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.