A technique for on-board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification.

Fang-Fang Yin1, Huaiqun Guan, Wenkai Lu.   

Abstract

The technologies with kilovoltage (kV) and megavoltage (MV) imaging in the treatment room are now available for image-guided radiation therapy to improve patient setup and target localization accuracy. However, development of strategies to efficiently and effectively implement these technologies for patient treatment remains challenging. This study proposed an aggregated technique for on-board CT reconstruction using combination of kV and MV beam projections to improve the data acquisition efficiency and image quality. These projections were acquired in the treatment room at the patient treatment position with a new kV imaging device installed on the accelerator gantry, orthogonal to the existing MV portal imaging device. The projection images for a head phantom and a contrast phantom were acquired using both the On-Board Imager kV imaging device and the MV portal imager mounted orthogonally on the gantry of a Varian Clinac 21EX linear accelerator. MV projections were converted into kV information prior to the aggregated CT reconstruction. The multilevel scheme algebraic-reconstruction technique was used to reconstruct CT images involving either full, truncated, or a combination of both full and truncated projections. An adaptive reconstruction method was also applied, based on the limited numbers of kV projections and truncated MV projections, to enhance the anatomical information around the treatment volume and to minimize the radiation dose. The effects of the total number of projections, the combination of kV and MV projections, and the beam truncation of MV projections on the details of reconstructed kV/MV CT images were also investigated.

Entities:  

Mesh:

Year:  2005        PMID: 16266096     DOI: 10.1118/1.1997307

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

3.  Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

Authors:  Yawei Zhang; Fang-Fang Yin; You Zhang; Lei Ren
Journal:  Phys Med Biol       Date:  2017-03-24       Impact factor: 3.609

4.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

5.  Towards clinical implementation of ultrafast combined kV-MV CBCT for IGRT of lung cancer : Evaluation of registration accuracy based on phantom study.

Authors:  Anna Arns; Manuel Blessing; Jens Fleckenstein; Dzmitry Stsepankou; Judit Boda-Heggemann; Anna Simeonova-Chergou; Jürgen Hesser; Frank Lohr; Frederik Wenz; Hansjörg Wertz
Journal:  Strahlenther Onkol       Date:  2016-02-10       Impact factor: 3.621

6.  Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Richard B Choroszucha; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2011-02-16       Impact factor: 3.609

7.  A phantom study on target localization accuracy using cone-beam computed tomography.

Authors:  Hui Yan; Liwei Zhang; Fang-Fang Yin
Journal:  Clin Med Oncol       Date:  2008-08-18

8.  A rapid, accurate image simulation strategy for mega-voltage cone-beam computed tomography.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Mathias Lehmann; Dianne Ferguson; Paul Baturin; Pascal Huber; Rony Fueglistaller; Thomas Harris; Ingrid Valencia Lozano; Christopher Williams; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-07-06       Impact factor: 4.174

9.  Dose comparison of megavoltage cone-beam and orthogonal-pair portal images.

Authors:  Lee-Cheng Peng; Ching-Chong Jack Yang; Sang Sim; Mitchell Weiss; Alex Bielajew
Journal:  J Appl Clin Med Phys       Date:  2006-03-27       Impact factor: 2.102

10.  Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator.

Authors:  K R Muralidhar; P Narayana Murthy; Rajneesh Kumar
Journal:  J Med Phys       Date:  2008-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.