Literature DB >> 9293805

Clinical validation of automatic quantitative defect size in rest technetium-99m-sestamibi myocardial perfusion SPECT.

X Kang1, D S Berman, K F Van Train, A M Amanullah, J Areeda, J D Friedman, H Kiat, G Germano.   

Abstract

UNLABELLED: We examined the relationships of automatic quantitative perfusion defect size and defect severity to rest left ventricular ejection fraction and semiquantitative visual sestamibi defect size in rest 99mTc-sestamibi SPECT in 40 consecutive patients with a history of myocardial infarction more than 30 days prior to testing. The purpose of this investigation was to validate the use of automatic quantitative rest sestamibi SPECT as a clinical measure of assessing relative infarction size.
METHODS: All patients received 20-30 mCi of 99mTc-sestamibi followed by SPECT imaging. Quantitative defect analysis used previously developed resting normal limits and an automatic version of a commercially available quantitative program (CEqual). Semiquantitative visual defect interpretation used a 20 segment/scan and five-point scoring analysis. First-pass (FP) radionuclide ventriculography (RVG) and gated sestamibi perfusion SPECT were each performed in 31 patients.
RESULTS: LVEF assessed by FP RVG was 37% +/- 15% (range 14%-62%) and 37% +/- 16% (range 12%-63%) by gated perfusion SPECT with high linear correlation (r = 0.96, n = 22) between the two methods. Myocardial perfusion defect size was 24% +/- 15% of LV (range 0%-50%) and defect severity was 1103 +/- 864 (range 0 to 2825) by automatic quantitative rest sestamibi. Perfusion defect size and defect severity both had close correlations with LVEF by FP RVG (r = -0.78, r = -0.86) and by gated perfusion SPECT (r = -0.75, r = -0.79). High linear correlations were observed between quantitative defect size and summed visual score of segments with score > or = 2 (r = 0.82) and the number of visually abnormal segments (r = 0.77), as well as between defect severity and visual summed rest score (r = 0.86) and the number of visually abnormal segments (r = 0.76).
CONCLUSION: Quantitation of rest sestamibi SPECT defect extent and severity using automatic CEqual correlates well with rest LVEF and with semiquantitative expert visual analysis. Results of this study define a strong relationship between measurements of 99mTc-sestamibi perfusion defect as measured by an automatic software program and global left ventricular function. The automatic quantitative program appears to be a useful measure of assessing infarct size in patients with remote myocardial infarction.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9293805

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  20 in total

1.  The challenge of quantifying defect size and severity: reality versus algorithm.

Authors:  R L Eisner; R E Patterson
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

2.  Clinical implication of down-scatter in attenuation-corrected myocardial SPECT.

Authors:  H Almquist; H Arheden; A H Arvidsson; O Pahlm; J Palmer
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

3.  An automatic method for quantification of myocardium at risk from myocardial perfusion SPECT in patients with acute coronary occlusion.

Authors:  Helen Soneson; Henrik Engblom; Erik Hedström; Frederic Bouvier; Peder Sörensson; John Pernow; Håkan Arheden; Einar Heiberg
Journal:  J Nucl Cardiol       Date:  2010-05-04       Impact factor: 5.952

4.  The oft neglected rest study.

Authors:  Mark I Travin
Journal:  J Nucl Cardiol       Date:  2008 Nov-Dec       Impact factor: 5.952

5.  Quantitation of infarct size in patients with chronic coronary artery disease using rest-redistribution Tl-201 myocardial perfusion SPECT: correlation with contrast-enhanced cardiac magnetic resonance.

Authors:  David S Fieno; Louise E J Thomson; Piotr Slomka; Aiden Abidov; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

6.  Evaluation of a decision support system for interpretation of myocardial perfusion gated SPECT.

Authors:  Milan Lomsky; Peter Gjertsson; Lena Johansson; Jens Richter; Mattias Ohlsson; Deborah Tout; Andries van Aswegen; S Richard Underwood; Lars Edenbrandt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-03-04       Impact factor: 9.236

7.  Predictors of an ischemic electrocardiographic response in patients with exercise-induced myocardial ischemia.

Authors:  Saurabh Malhotra; William P Follansbee; Prem Soman
Journal:  J Nucl Cardiol       Date:  2011-06-14       Impact factor: 5.952

8.  Relationship between silent myocardial ischemia and coronary artery disease risk factors.

Authors:  Saurabh Malhotra; Ravi Sharma; Dustin E Kliner; William P Follansbee; Prem Soman
Journal:  J Nucl Cardiol       Date:  2013-05-30       Impact factor: 5.952

9.  Relationship of infarct size and severity versus left ventricular ejection fraction and volumes obtained from 99mTc-sestamibi gated single-photon emission computed tomography in patients treated with primary percutaneous coronary intervention.

Authors:  Roberto Sciagrà; Alessio Imperiale; David Antoniucci; Angela Migliorini; Guido Parodi; Giannetto Comis; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-05       Impact factor: 9.236

10.  Diagnosis of regional cerebral blood flow abnormalities using spect: agreement between individualized statistical parametric maps and visual inspection by nuclear medicine physicians with different levels of expertise in nuclear neurology.

Authors:  Euclides Timóteo da Rocha; Carlos Alberto Buchpiguel; Ricardo Nitrini; Sergio Tazima; Stela Verzinhase Peres; Geraldo Busatto Filho
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.