Literature DB >> 16260661

Mid-term wear characteristics of an uncemented acetabular component.

J H M Goosen1, C C P M Verheyen, N J A Tulp.   

Abstract

We investigated the rate of polyethylene wear of a cementless acetabular component at different periods of follow-up in order to test the hypothesis than an irrecoverable deformation process (creep) was followed by an initially low, but gradually increasing wear rate. We studied prospectively 93 uncemented total hip arthroplasties in 83 patients (mean age 50 years (22 to 63)) with a mean follow-up of 8.2 years (3 to 12). We measured the penetration of the femoral head from radiographs taken immediately after surgery at three, six and nine years, or at the latest follow-up. The median wear rate was 0.17 mm per year in the first three years, a finding which we considered to be caused by creep. Thereafter, the rate of wear declined to 0.07 mm per year (four- to six-year period) and then increased to 0.17 mm per year (seven to nine years) and 0.27 mm per year (more than nine years), which we considered to be a reflection of genuine polyethylene wear. After the nine-year follow-up the wear rates were higher in patients with marked osteolysis. We found no relationship between the inclination angle of the acetabular component or femoral head orientation and the rate of wear. No acetabular component required revision.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16260661     DOI: 10.1302/0301-620X.87B11.16101

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  4 in total

Review 1.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

3.  Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.

Authors:  Nicholas D Clement; Martin Mitchell; Morag E Trayner; Daniel E Porter; Graham M Lawson; Richard Burnett
Journal:  Int Orthop       Date:  2013-08-22       Impact factor: 3.075

4.  Long-term Results of Primary Hip Arthroplasty with Cup Inclination Angle Bigger than Fifty Degrees.

Authors:  Jialiang Tian; Li Sun; Ruiyin Hu; Wei Han; Xiaobin Tian
Journal:  J Clin Orthop Trauma       Date:  2017-04-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.