Literature DB >> 16258995

Electrostatic charge characteristics of aerosols produced from metered dose inhalers.

Philip Chi Lip Kwok1, William Glover, Hak-Kim Chan.   

Abstract

The electrostatic charge properties of aerosols produced by commercial metered dose inhalers (MDIs), including Ventolin, QVAR, Flixotide, Intal Forte, and Tilade were studied using a modified 13-stage electrical low pressure impactor (ELPI) with aerodynamic diameter cutoff ranging from 0.028 to 10.07 microm. All the stages are electrically insulated from each other with the last 12 stages connected individually to electrometers with sensitivity at femtoampere levels. Aerosol particles deposited on the impactor stages according to their aerodynamic diameters and their charges were measured by the electrometers. The deposited drug mass was assayed chemically using HPLC. The results show that particles of bipolar charge distribution were produced reproducibly from Intal Forte, Tilade, and Flixotide. In contrast, those from Ventolin and QVAR displayed charge variation, depending on the time lapse between actuations. This suggests that charge relaxation may influence the charging of these two MDIs. Mass distributions were reproducible for all MDIs except for Ventolin, the first puff from which was always the highest in dose. The different charge characteristics of the MDIs could be attributed to differences in the drug and formulation as well as valve materials. In general, submicron particles showed a larger variation in the charge-to-mass ratio (q/m). This indicated charge contribution by propellant/excipients (which produce submicron particles) rather than the drug itself. The calculated number of elementary charges per drug particle of size <or= 6.06 microm ranged from zero to several ten thousands. The charge level is sufficiently high to have a potential effect on the deposition of the inhaled particles in the respiratory tract. In conclusion, the ELPI provided more detailed charge information about the MDI aerosol particles. Different aerosol charge profiles were shown by commercial MDIs, and the results can be explained by variation in the drug, formulation and the MDI materials. The results may have practical significance on lung deposition of MDI aerosols and regulatory aspects of generic aerosol products. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16258995     DOI: 10.1002/jps.20395

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  16 in total

Review 1.  Lipid-based pulmonary delivery system: a review and future considerations of formulation strategies and limitations.

Authors:  Cheng Loong Ngan; Azren Aida Asmawi
Journal:  Drug Deliv Transl Res       Date:  2018-10       Impact factor: 4.617

Review 2.  Minimizing variability of cascade impaction measurements in inhalers and nebulizers.

Authors:  Matthew Bonam; David Christopher; David Cipolla; Brent Donovan; David Goodwin; Susan Holmes; Svetlana Lyapustina; Jolyon Mitchell; Steve Nichols; Gunilla Pettersson; Chris Quale; Nagaraja Rao; Dilraj Singh; Terrence Tougas; Mike Van Oort; Bernd Walther; Bruce Wyka
Journal:  AAPS PharmSciTech       Date:  2008-02-28       Impact factor: 3.246

3.  Aerodynamic and electrostatic properties of model dry powder aerosols: a comprehensive study of formulation factors.

Authors:  M J Telko; A J Hickey
Journal:  AAPS PharmSciTech       Date:  2014-06-18       Impact factor: 3.246

4.  The Effect of Active Pharmaceutical Ingredients on Aerosol Electrostatic Charges from Pressurized Metered Dose Inhalers.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2015-03-19       Impact factor: 4.200

5.  Measuring The Bipolar Charge Distributions of Fine Particle Aerosol Clouds of Commercial PMDI Suspensions Using a Bipolar Next Generation Impactor (bp-NGI).

Authors:  Martin Rowland; Alessandro Cavecchi; Frank Thielmann; Janusz Kulon; Jag Shur; Robert Price
Journal:  Pharm Res       Date:  2018-11-26       Impact factor: 4.200

6.  The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2014-10-01       Impact factor: 4.200

7.  The influence of actuator materials and nozzle designs on electrostatic charge of pressurised metered dose inhaler (pMDI) formulations.

Authors:  Yang Chen; Paul M Young; David F Fletcher; Hak Kim Chan; Edward Long; David Lewis; Tanya Church; Daniela Traini
Journal:  Pharm Res       Date:  2013-12-03       Impact factor: 4.200

8.  Investigation of electrostatic behavior of a lactose carrier for dry powder inhalers.

Authors:  Keat Theng Chow; Kewu Zhu; Reginald B H Tan; Paul W S Heng
Journal:  Pharm Res       Date:  2008-06-26       Impact factor: 4.200

9.  Applicability of Bipolar Charge Analyzer (BOLAR) in Characterizing the Bipolar Electrostatic Charge Profile of Commercial Metered Dose Inhalers (MDIs).

Authors:  Sharon Shui Yee Leung; Adam Chong Ming Chiow; Ari Ukkonen; Hak-Kim Chan
Journal:  Pharm Res       Date:  2015-09-03       Impact factor: 4.200

10.  Design of a device for simultaneous particle size and electrostatic charge measurement of inhalation drugs.

Authors:  Kewu Zhu; Wai Kiong Ng; Shoucang Shen; Reginald B H Tan; Paul W S Heng
Journal:  Pharm Res       Date:  2008-07-01       Impact factor: 4.200

View more