Prevention of high-dose-rate brachytherapy accidents. ICRP Publication 97.

J Valentin1.   

Abstract

High-dose-rate brachytherapy is a rapidly growing technique (HDR) that has been replacing low-dose-rate (LDR) procedures over the last few years in both industrialised and developing countries. It is estimated that about 500,000 procedures (administration of treatment) are performed by HDR units annually. LDR equipment has been discontinued by many manufacturers over the last few years, leaving HDR brachytherapy as the major alternative. HDR brachytherapy techniques deliver a very high dose, of the order of 1.6-5.0 Gy/min, so mistakes can lead to under- or overdosage with the potential for clinical adverse effects. More than 500 HDR accidents (including one death) have been reported along the entire chain of procedures from source packing to delivery of dose. Human error has been the prime cause of radiation events. In the present report, the International Commission on Radiological Protection concludes that many accidents could have been prevented if staff had had functional monitoring equipment and paid attention to the results. Since iridium has relatively short half-life, the HDR sources need to be replaced approximately every 4 months. Over 10,000 HDR sources are transported annually, with the resultant potential for accidents; therefore, appropriate procedures and regulations must be observed. A number of specific recommendations on procedures and equipment are given in this report. The need for an emergency plan and for practising emergency procedures is stressed. The possibility of loss or theft of sources must be kept in mind. A collaborating team of specifically trained personnel following quality assurance (QA) procedures is necessary to prevent accidents. Maintenance is indispensable component of QA; external audits of procedures re-enforce good and safe practice, and identify potential causes of accidents. QA should include peer review of cases. Accidents and incidents should be reported and the lessons learned should be shared with other users to prevent similar mistakes.

Entities:  

Mesh:

Year:  2005        PMID: 16243099     DOI: 10.1016/j.icrp.2005.05.002

Source DB:  PubMed          Journal:  Ann ICRP        ISSN: 0146-6453


  10 in total

Review 1.  Dosimetric audit in brachytherapy.

Authors:  A L Palmer; D A Bradley; A Nisbet
Journal:  Br J Radiol       Date:  2014-05-06       Impact factor: 3.039

2.  A program for the independent verification of brachytherapy planning system calculations.

Authors:  Vicente Carmona; Jose Perez-Calatayud; Françoise Lliso; Jose Richart; Facundo Ballester; Mª Carmen Pujades-Claumarchirant; Jack L M Venselaar
Journal:  J Contemp Brachytherapy       Date:  2010-10-13

Review 3.  Electromagnetic tracking for treatment verification in interstitial brachytherapy.

Authors:  Christoph Bert; Markus Kellermeier; Kari Tanderup
Journal:  J Contemp Brachytherapy       Date:  2016-11-02

4.  New era of electronic brachytherapy.

Authors:  Prabhakar Ramachandran
Journal:  World J Radiol       Date:  2017-04-28

Review 5.  In vivo dosimetry in brachytherapy: Requirements and future directions for research, development, and clinical practice.

Authors:  Gabriel P Fonseca; Jacob G Johansen; Ryan L Smith; Luc Beaulieu; Sam Beddar; Gustavo Kertzscher; Frank Verhaegen; Kari Tanderup
Journal:  Phys Imaging Radiat Oncol       Date:  2020-09-28

6.  In Vivo Verification of Treatment Source Dwell Times in Brachytherapy of Postoperative Endometrial Carcinoma: A Feasibility Study.

Authors:  Antonio Herreros; José Pérez-Calatayud; Facundo Ballester; Jose Barrera-Gómez; Rosa Abellana; Joana Melo; Luis Moutinho; Luca Tagliaferri; Ángeles Rovirosa
Journal:  J Pers Med       Date:  2022-05-31

7.  Patient safety program and incident review of high-dose-rate brachytherapy at an academic center in Thailand.

Authors:  Lalida Tuntipumiamorn; Kanitta Kamplong; Bhuvadol Pengchantr; Kantarat Rojanapan; Porntip Iampongpaiboon; Yaowalak Chansilpa
Journal:  J Contemp Brachytherapy       Date:  2022-08-17

8.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

9.  Treatment plan dosimetric impact after catheter stretch during multi-catheter interstitial breast brachytherapy.

Authors:  Eeva Boman; Dean Paterson; Junou Huang; Shelley Pearson; Carol Johnson
Journal:  J Contemp Brachytherapy       Date:  2017-10-20

10.  First experience of 192Ir source stuck event during high-dose-rate brachytherapy in Japan.

Authors:  Shinobu Kumagai; Norikazu Arai; Takeshi Takata; Daisuke Kon; Toshiya Saitoh; Hiroshi Oba; Shigeru Furui; Jun'ichi Kotoku; Kenshiro Shiraishi
Journal:  J Contemp Brachytherapy       Date:  2020-02-28