Literature DB >> 16229417

Time-delay- and time-reversal-based robust Capon beamformers for ultrasound imaging.

Zhisong Wang1, Jian Li, Renbiao Wu.   

Abstract

Currently, the nonadaptive delay-and-sum (DAS) beamformer is extensively used for ultrasound imaging, despite the fact that it has lower resolution and worse interference suppression capability than the adaptive standard Capon beamformer (SCB) if the steering vector corresponding to the signal of interest (SOI) is accurately known. The main problem which restricts the use of SCB, however, is that SCB lacks robustness against steering vector errors that are inevitable in practice. Whenever this happens, the performance of SCB may hecome worse than that of DAS. Therefore, a robust adaptive beamformer is desirable to maintain the robustness of DAS and adaptivity of SCB. In this paper we consider a recent promising robust Capon beamformer (RCB) for ultrasound imaging. We propose two ways of implementing RCB, one based on time delay and the other based on time reversal. RCB extends SCB by allowing the array steering vector to be within an uncertainty set. Hence, it restores the appeal of SCB including its high resolution and superb interference suppression capabilities, and also retains the attractiveness of DAS including its robustness against steering vector errors. The time-delay-based RCB can tolerate the misalignment of data samples and the time-reversal-based RCB can withstand the uncertainty of the Green's function. Both time-delay-based RCB and time-reversal-based RCB can be efficiently computed at a comparable cost to SCB. The excellent performances of the proposed robust adaptive beamforming approaches are demonstrated via a number of simulated and experimental examples.

Entities:  

Mesh:

Year:  2005        PMID: 16229417     DOI: 10.1109/TMI.2005.857222

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Weighted Capon beamformer combined with coded excitation in ultrasound imaging.

Authors:  Seyed Amin Izadi; Ali Mahloojifar; Babak Mohammadzadeh Asl
Journal:  J Med Ultrason (2001)       Date:  2015-07-28       Impact factor: 1.314

2.  Time-domain optimized near-field estimator for ultrasound imaging: initial development and results.

Authors:  F Viola; M A Ellis; W F Walker
Journal:  IEEE Trans Med Imaging       Date:  2008-01       Impact factor: 10.048

3.  A sidelobe suppressing near-field beamforming approach for ultrasound array imaging.

Authors:  Zhengyao He; Fan Zheng; Yuanliang Ma; Hyung Ham Kim; Qifa Zhou; K Kirk Shung
Journal:  J Acoust Soc Am       Date:  2015-05       Impact factor: 1.840

4.  Super-resolution image reconstruction using diffuse source models.

Authors:  Michael A Ellis; Francesco Viola; William F Walker
Journal:  Ultrasound Med Biol       Date:  2010-05-05       Impact factor: 2.998

5.  Short-lag spatial coherence of backscattered echoes: imaging characteristics.

Authors:  Muyinatu A Lediju; Gregg E Trahey; Brett C Byram; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-07       Impact factor: 2.725

6.  A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.

Authors:  Kazuyuki Dei; Brett Byram
Journal:  Ultrasonics       Date:  2018-04-25       Impact factor: 2.890

7.  Optimization of Transmit Parameters in Cardiac Strain Imaging With Full and Partial Aperture Coherent Compounding.

Authors:  Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-05       Impact factor: 2.725

8.  MARIA M4: clinical evaluation of a prototype ultrawideband radar scanner for breast cancer detection.

Authors:  Alan W Preece; Ian Craddock; Mike Shere; Lyn Jones; Helen L Winton
Journal:  J Med Imaging (Bellingham)       Date:  2016-07-20

9.  Robust finite impulse response beamforming applied to medical ultrasound.

Authors:  Drake A Guenther; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-06       Impact factor: 2.725

10.  Internal-Illumination Photoacoustic Tomography Enhanced by a Graded-Scattering Fiber Diffuser.

Authors:  Mucong Li; Tri Vu; Georgy Sankin; Brenton Winship; Kohldon Boydston; Russell Terry; Pei Zhong; Junjie Yao
Journal:  IEEE Trans Med Imaging       Date:  2020-12-29       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.