Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT.

Mohammad Reza Ay1, Habib Zaidi.   

Abstract

An x-ray computed tomography (CT) simulator based on the Monte Carlo N-particle radiation transport computer code (MCNP4C) was developed for simulation of both fan- and cone-beam CT scanners. A user-friendly interface running under Matlab 6.5.1 creates the scanner geometry at different views as MCNP4C's input file. The full simulation of x-ray tube, phantom and detectors with single-slice, multi-slice and flat detector configurations was considered. The simulator was validated through comparison with experimental measurements of different nonuniform phantoms with varying sizes on both a clinical and a small-animal CT scanner. There is good agreement between the simulated and measured projections and reconstructed images. Thereafter, the effects of bow-tie filter, phantom size and septa length on scatter distribution in fan-beam CT were studied in detail. The relative difference between detected total, primary and scatter photons for septa length varying between 0 and 95 mm is 11.2%, 1.9% and 84.1%, respectively, whereas the scatter-to-primary ratio decreases by 83.8%. The developed simulator is a powerful tool for evaluating the effect of physical, geometrical and other design parameters on scanner performance and image quality in addition to offering a versatile tool for investigating potential artefacts and correction schemes when using CT-based attenuation correction on dual-modality PET/CT units.

Entities:  

Mesh:

Year:  2005        PMID: 16204878     DOI: 10.1088/0031-9155/50/20/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

Review 1.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

2.  Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.

Authors:  Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-19       Impact factor: 9.236

3.  Compressed voxels for high-resolution phantom simulations in GATE.

Authors:  Richard Taschereau; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2008 Jan-Feb       Impact factor: 3.488

Review 4.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

5.  Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe.

Authors:  Sarah E McKenney; Anita Nosratieh; Dale Gelskey; Kai Yang; Shin-Ying Huang; Lin Chen; John M Boone
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

6.  Determination and verification of the x-ray spectrum of a CT scanner.

Authors:  Ahmad Ibrahim Hassan; Martin Skalej; Helmut Schlattl; Christoph Hoeschen
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-07

7.  Direct and fast measurement of CT beam filter profiles with simultaneous geometrical calibration.

Authors:  Kai Yang; Xinhua Li; X George Xu; Bob Liu
Journal:  Med Phys       Date:  2017-01       Impact factor: 4.071

8.  Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes.

Authors:  Homa Hayati; Asghar Mesbahi; Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2015-07-25

9.  The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.

Authors:  J Gu; B Bednarz; P F Caracappa; X G Xu
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

10.  Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography.

Authors:  Kiranjit Sekhon; Galateia J Kazakia; Andrew J Burghardt; Bryan Hermannsson; Sharmila Majumdar
Journal:  Bone       Date:  2009-06-06       Impact factor: 4.398

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.